{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1417518176"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1417518176","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Local Particle Velocity Measurements In Slurry Flow In Pipes And Centrifugal Pumps Using Ultrasound Technique","abstract":"The movement of slurries can cause significant wear, especially in places where slurry flow changes its direction, such as in pumps, elbows, valves etc. Therefore, wear is considered as one of the most important concerns for slurry flows as it affects the life, as well as the hydraulic, and the mechanical performance of the pumping system.The cooperation between the Case Western University's Department of Mechanical Engineering and the GIW Industries Inc. has included experimental work in order to study the Local Particle Concentration LPC in the vertical test section and within the pump casing as a first stage. The second stage was to study the Local Particle Velocity LPV in the vertical test section and within the pump casing. The information from the LPC & LPV can be used to calculate the rate of wear within the pump using CFD codes.This project involves applying the ultrasound technique to measure the local particle velocity within the pump using a Pulsed Ultrasound Doppler Velocimetry Device (PUDV). The experimental results are then compared with Computational Fluid Dynamics (CFD) Results. Different setups have been used to conduct experiments to determine which setup is appropriate for the current study, Different techniques have been used to determine the LPV such as direct or indirect measurement of the particle velocity (i.e. the two-measurement technique). Based on the obtained results, the two-measurement technique is the most suitable way to measure the particle velocity profile.","abstract_html":"The movement of slurries can cause significant wear, especially in places where slurry flow changes its direction, such as in pumps, elbows, valves etc. Therefore, wear is considered as one of the most important concerns for slurry flows as it affects the life, as well as the hydraulic, and the mechanical performance of the pumping system.The cooperation between the Case Western University&#x27;s Department of Mechanical Engineering and the GIW Industries Inc. has included experimental work in order to study the Local Particle Concentration LPC in the vertical test section and within the pump casing as a first stage. The second stage was to study the Local Particle Velocity LPV in the vertical test section and within the pump casing. The information from the LPC &amp; LPV can be used to calculate the rate of wear within the pump using CFD codes.This project involves applying the ultrasound technique to measure the local particle velocity within the pump using a Pulsed Ultrasound Doppler Velocimetry Device (PUDV). The experimental results are then compared with Computational Fluid Dynamics (CFD) Results. Different setups have been used to conduct experiments to determine which setup is appropriate for the current study, Different techniques have been used to determine the LPV such as direct or indirect measurement of the particle velocity (i.e. the two-measurement technique). Based on the obtained results, the two-measurement technique is the most suitable way to measure the particle velocity profile.","abstract_has_math":false,"creators":["Garman, Mohamed Ammar"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kadambi, Jaikrishnan"],"committee_members":[],"year":2015,"date_issued":"2015-02-06","date_published":"2015-02-06","updated_at":"2026-11-27T04:40:07Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1417518176","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1417518176","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1417518176","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1417518176","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kadambi, Jaikrishnan"]},{"key":"dc:creator","label":"Author","values":["Garman, Mohamed Ammar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-02-06"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1417518176"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The movement of slurries can cause significant wear, especially in places where slurry flow changes its direction, such as in pumps, elbows, valves etc. Therefore, wear is considered as one of the most important concerns for slurry flows as it affects the life, as well as the hydraulic, and the mechanical performance of the pumping system.The cooperation between the Case Western University's Department of Mechanical Engineering and the GIW Industries Inc. has included experimental work in order to study the Local Particle Concentration LPC in the vertical test section and within the pump casing as a first stage. The second stage was to study the Local Particle Velocity LPV in the vertical test section and within the pump casing. The information from the LPC & LPV can be used to calculate the rate of wear within the pump using CFD codes.This project involves applying the ultrasound technique to measure the local particle velocity within the pump using a Pulsed Ultrasound Doppler Velocimetry Device (PUDV). The experimental results are then compared with Computational Fluid Dynamics (CFD) Results. Different setups have been used to conduct experiments to determine which setup is appropriate for the current study, Different techniques have been used to determine the LPV such as direct or indirect measurement of the particle velocity (i.e. the two-measurement technique). Based on the obtained results, the two-measurement technique is the most suitable way to measure the particle velocity profile."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.149","2.7 MB"]},{"key":"dc:title","label":"Title","values":["Local Particle Velocity Measurements In Slurry Flow In Pipes And Centrifugal Pumps Using Ultrasound Technique"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Kadambi, Jaikrishnan"],"dc:creator":["Garman, Mohamed Ammar"],"dc:date":["2015-02-06"],"dc:description":["The movement of slurries can cause significant wear, especially in places where slurry flow changes its direction, such as in pumps, elbows, valves etc. Therefore, wear is considered as one of the most important concerns for slurry flows as it affects the life, as well as the hydraulic, and the mechanical performance of the pumping system.The cooperation between the Case Western University's Department of Mechanical Engineering and the GIW Industries Inc. has included experimental work in order to study the Local Particle Concentration LPC in the vertical test section and within the pump casing as a first stage. The second stage was to study the Local Particle Velocity LPV in the vertical test section and within the pump casing. The information from the LPC & LPV can be used to calculate the rate of wear within the pump using CFD codes.This project involves applying the ultrasound technique to measure the local particle velocity within the pump using a Pulsed Ultrasound Doppler Velocimetry Device (PUDV). The experimental results are then compared with Computational Fluid Dynamics (CFD) Results. Different setups have been used to conduct experiments to determine which setup is appropriate for the current study, Different techniques have been used to determine the LPV such as direct or indirect measurement of the particle velocity (i.e. the two-measurement technique). Based on the obtained results, the two-measurement technique is the most suitable way to measure the particle velocity profile."],"dc:format":["application/pdf","p.149","2.7 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1417518176"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Mechanical Engineering"],"dc:title":["Local Particle Velocity Measurements In Slurry Flow In Pipes And Centrifugal Pumps Using Ultrasound Technique"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:07Z"}