{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1428056825"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1428056825","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Investigating Hemodynamics of the Developing Embryonic Heart using Optical Coherence Tomography","abstract":"Blood flow is a critical factor that regulates developmental programs during cardiogenesis. During early embryonic development, deviations from the normal blood flow pattern have been shown to lead to congenital heart defects including septal defects and outflow tract anomalies. To better understand the role flow and the resulting hemodynamic forces play during cardiovascular development precise tools are needed to rapidly calculate and monitor these forces. Optical coherence tomography (OCT) is a noninvasive imaging modality that is well suited for imaging the developing heart due to its high spatial and temporal resolution. OCT is also capable of analyzing various cardiac functions by measuring the blood flow through the developing heart via the Doppler effect. Here we present several techniques we have developed that use structural and Doppler OCT to monitor and measure hemodynamic parameters in the early embryonic heart. First, we generated 4-D (3-D volumes over time) shear stress maps from Doppler OCT data sets. These maps enabled comparisons of shear stress from the inner curvature versus the outer curvature at different regions of the looping heart tube over the duration of a heartbeat. We also developed an orientation independent technique for measuring the absolute blood flow in a vessel from individual cross sectional images. This technique utilizes a dual angle delay encoding technique to obtain instantaneous pulsatile blood flow measurements irrespective of the vessel orientation. We used this technique to image the aortic arches in control and ethanol exposed embryos. The aortic arches undergo a significant morphogenesis from a symmetrical system of paired vessels to an asymmetrical structure and hemodynamics is thought to play a critical role in this transformation. Blood flow and shear stress were both calculated as well as the cross sectional area of the pharyngeal tissue surrounding the aortic arch vessel. Finally, we developed a technique for measuring the contractile wave velocity in different regions of the heart tube. These values were then compared with conduction velocities obtained from optical mapping. Here we have developed and demonstrated a range of novel techniques for measuring cardiac function in the developing embryonic heart. These techniques may prove to be powerful tools for future investigations of the role of blood flow and the resulting hemodynamic forces play in congenital heart defects.","abstract_html":"Blood flow is a critical factor that regulates developmental programs during cardiogenesis. During early embryonic development, deviations from the normal blood flow pattern have been shown to lead to congenital heart defects including septal defects and outflow tract anomalies. To better understand the role flow and the resulting hemodynamic forces play during cardiovascular development precise tools are needed to rapidly calculate and monitor these forces. Optical coherence tomography (OCT) is a noninvasive imaging modality that is well suited for imaging the developing heart due to its high spatial and temporal resolution. OCT is also capable of analyzing various cardiac functions by measuring the blood flow through the developing heart via the Doppler effect. Here we present several techniques we have developed that use structural and Doppler OCT to monitor and measure hemodynamic parameters in the early embryonic heart. First, we generated 4-D (3-D volumes over time) shear stress maps from Doppler OCT data sets. These maps enabled comparisons of shear stress from the inner curvature versus the outer curvature at different regions of the looping heart tube over the duration of a heartbeat. We also developed an orientation independent technique for measuring the absolute blood flow in a vessel from individual cross sectional images. This technique utilizes a dual angle delay encoding technique to obtain instantaneous pulsatile blood flow measurements irrespective of the vessel orientation. We used this technique to image the aortic arches in control and ethanol exposed embryos. The aortic arches undergo a significant morphogenesis from a symmetrical system of paired vessels to an asymmetrical structure and hemodynamics is thought to play a critical role in this transformation. Blood flow and shear stress were both calculated as well as the cross sectional area of the pharyngeal tissue surrounding the aortic arch vessel. Finally, we developed a technique for measuring the contractile wave velocity in different regions of the heart tube. These values were then compared with conduction velocities obtained from optical mapping. Here we have developed and demonstrated a range of novel techniques for measuring cardiac function in the developing embryonic heart. These techniques may prove to be powerful tools for future investigations of the role of blood flow and the resulting hemodynamic forces play in congenital heart defects.","abstract_has_math":false,"creators":["Peterson, Lindsy Marie"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Rollins, Andrew"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06-03","date_published":"2015-06-03","updated_at":"2026-11-26T05:22:56Z","subjects":["Biomedical Engineering","Developmental Biology","optical coherence tomography","doppler","hemodynamics","embryonic heart development","shear stress","absolute flow","aortic arch"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1428056825","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1428056825","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1428056825","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1428056825","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rollins, Andrew"]},{"key":"dc:creator","label":"Author","values":["Peterson, Lindsy Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-06-03"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Developmental Biology","optical coherence tomography","doppler","hemodynamics","embryonic heart development","shear stress","absolute flow","aortic arch"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1428056825"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Blood flow is a critical factor that regulates developmental programs during cardiogenesis. During early embryonic development, deviations from the normal blood flow pattern have been shown to lead to congenital heart defects including septal defects and outflow tract anomalies. To better understand the role flow and the resulting hemodynamic forces play during cardiovascular development precise tools are needed to rapidly calculate and monitor these forces. Optical coherence tomography (OCT) is a noninvasive imaging modality that is well suited for imaging the developing heart due to its high spatial and temporal resolution. OCT is also capable of analyzing various cardiac functions by measuring the blood flow through the developing heart via the Doppler effect. Here we present several techniques we have developed that use structural and Doppler OCT to monitor and measure hemodynamic parameters in the early embryonic heart. First, we generated 4-D (3-D volumes over time) shear stress maps from Doppler OCT data sets. These maps enabled comparisons of shear stress from the inner curvature versus the outer curvature at different regions of the looping heart tube over the duration of a heartbeat. We also developed an orientation independent technique for measuring the absolute blood flow in a vessel from individual cross sectional images. This technique utilizes a dual angle delay encoding technique to obtain instantaneous pulsatile blood flow measurements irrespective of the vessel orientation. We used this technique to image the aortic arches in control and ethanol exposed embryos. The aortic arches undergo a significant morphogenesis from a symmetrical system of paired vessels to an asymmetrical structure and hemodynamics is thought to play a critical role in this transformation. Blood flow and shear stress were both calculated as well as the cross sectional area of the pharyngeal tissue surrounding the aortic arch vessel. Finally, we developed a technique for measuring the contractile wave velocity in different regions of the heart tube. These values were then compared with conduction velocities obtained from optical mapping. Here we have developed and demonstrated a range of novel techniques for measuring cardiac function in the developing embryonic heart. These techniques may prove to be powerful tools for future investigations of the role of blood flow and the resulting hemodynamic forces play in congenital heart defects."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.150","6.11 MB"]},{"key":"dc:title","label":"Title","values":["Investigating Hemodynamics of the Developing Embryonic Heart using Optical Coherence Tomography"]}]}],"canonical_facts":{"dc:contributor":["Rollins, Andrew"],"dc:creator":["Peterson, Lindsy Marie"],"dc:date":["2015-06-03"],"dc:description":["Blood flow is a critical factor that regulates developmental programs during cardiogenesis. During early embryonic development, deviations from the normal blood flow pattern have been shown to lead to congenital heart defects including septal defects and outflow tract anomalies. To better understand the role flow and the resulting hemodynamic forces play during cardiovascular development precise tools are needed to rapidly calculate and monitor these forces. Optical coherence tomography (OCT) is a noninvasive imaging modality that is well suited for imaging the developing heart due to its high spatial and temporal resolution. OCT is also capable of analyzing various cardiac functions by measuring the blood flow through the developing heart via the Doppler effect. Here we present several techniques we have developed that use structural and Doppler OCT to monitor and measure hemodynamic parameters in the early embryonic heart. First, we generated 4-D (3-D volumes over time) shear stress maps from Doppler OCT data sets. These maps enabled comparisons of shear stress from the inner curvature versus the outer curvature at different regions of the looping heart tube over the duration of a heartbeat. We also developed an orientation independent technique for measuring the absolute blood flow in a vessel from individual cross sectional images. This technique utilizes a dual angle delay encoding technique to obtain instantaneous pulsatile blood flow measurements irrespective of the vessel orientation. We used this technique to image the aortic arches in control and ethanol exposed embryos. The aortic arches undergo a significant morphogenesis from a symmetrical system of paired vessels to an asymmetrical structure and hemodynamics is thought to play a critical role in this transformation. Blood flow and shear stress were both calculated as well as the cross sectional area of the pharyngeal tissue surrounding the aortic arch vessel. Finally, we developed a technique for measuring the contractile wave velocity in different regions of the heart tube. These values were then compared with conduction velocities obtained from optical mapping. Here we have developed and demonstrated a range of novel techniques for measuring cardiac function in the developing embryonic heart. These techniques may prove to be powerful tools for future investigations of the role of blood flow and the resulting hemodynamic forces play in congenital heart defects."],"dc:format":["application/pdf","p.150","6.11 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1428056825"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Developmental Biology","optical coherence tomography","doppler","hemodynamics","embryonic heart development","shear stress","absolute flow","aortic arch"],"dc:title":["Investigating Hemodynamics of the Developing Embryonic Heart using Optical Coherence Tomography"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T05:22:56Z"}