{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1432223568"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1432223568","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Integrated Microsystems for High-Fidelity Sensing and Manipulation of Brain Neurochemistry","abstract":"This project has developed two integrated microsystems fabricated in a 0.35-µm two-poly four-metal CMOS process for high-fidelity sensing and manipulation of brain neurochemistry. In particular, first, a system-on-chip (SoC) has been developed for neurochemical pattern generation <i>in vivo</i>. This SoC uniquely integrates electrical stimulation with embedded timing management for generation of neurochemical patterns and 400V/s fast-scan cyclic voltammetry (FSCV) sensing at a carbon-fiber microelectrode (CFM), for subsequent assessment of fidelity in the generated profiles, and manages a novel switched-electrode scheme that eliminates the possibility of large stimulus artifacts adversely affecting electrochemistry. The SoC also leverages the discontinuous sampling inherent in FSCV to reduce the sensing power consumption by 87.5% to 9.3µW from 2.5V using a duty-cycled, 3rd-order, continuous-time, delta-sigma modulator (CT-ΔΣM) with an input-referred noise current of 78pA<sub>rms</sub> (dc – 5 kHz) within an input current range of ±950nA. Utilizing a transfer function that relates electrical stimulation of dopamine axons traversing the medial forebrain bundle (MFB) to evoked extracellular dopamine dynamics in the dorsal striatum of the forebrain, the correlation coefficient between predicted and measured dopamine temporal profiles was found to be 0.95 in an anesthetized rat.Next, the second SoC has been developed for closed-loop regulation of brain dopamine. This SoC uniquely integrates neurochemical sensing, on-the-fly chemometrics, and feedback-controlled electrical microstimulation to mimic a “neurochemical thermostat” by maintaining brain levels of electrically evoked dopamine between two user-set thresholds. The SoC incorporates a 90µW, custom-designed, digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by 400V/s FSCV at a CFM. Specifically, the DSP unit executes a chemometrics algorithm based upon principal component regression (PCR) to resolve in real time electrically evoked brain dopamine levels from pH change and CFM background-current drift, two common interferents encountered with FSCV at a CFM in vivo. Further, the DSP unit directly links the chemically resolved dopamine levels to the activation of the electrical microstimulator in on-off-keying (OOK) fashion. Measured results from benchtop testing, flow injection analysis (FIA), and biological experiments with an anesthetized rat are presented.","abstract_html":"This project has developed two integrated microsystems fabricated in a 0.35-µm two-poly four-metal CMOS process for high-fidelity sensing and manipulation of brain neurochemistry. In particular, first, a system-on-chip (SoC) has been developed for neurochemical pattern generation &lt;i&gt;in vivo&lt;/i&gt;. This SoC uniquely integrates electrical stimulation with embedded timing management for generation of neurochemical patterns and 400V/s fast-scan cyclic voltammetry (FSCV) sensing at a carbon-fiber microelectrode (CFM), for subsequent assessment of fidelity in the generated profiles, and manages a novel switched-electrode scheme that eliminates the possibility of large stimulus artifacts adversely affecting electrochemistry. The SoC also leverages the discontinuous sampling inherent in FSCV to reduce the sensing power consumption by 87.5% to 9.3µW from 2.5V using a duty-cycled, 3rd-order, continuous-time, delta-sigma modulator (CT-ΔΣM) with an input-referred noise current of 78pA&lt;sub&gt;rms&lt;/sub&gt; (dc – 5 kHz) within an input current range of ±950nA. Utilizing a transfer function that relates electrical stimulation of dopamine axons traversing the medial forebrain bundle (MFB) to evoked extracellular dopamine dynamics in the dorsal striatum of the forebrain, the correlation coefficient between predicted and measured dopamine temporal profiles was found to be 0.95 in an anesthetized rat.Next, the second SoC has been developed for closed-loop regulation of brain dopamine. This SoC uniquely integrates neurochemical sensing, on-the-fly chemometrics, and feedback-controlled electrical microstimulation to mimic a “neurochemical thermostat” by maintaining brain levels of electrically evoked dopamine between two user-set thresholds. The SoC incorporates a 90µW, custom-designed, digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by 400V/s FSCV at a CFM. Specifically, the DSP unit executes a chemometrics algorithm based upon principal component regression (PCR) to resolve in real time electrically evoked brain dopamine levels from pH change and CFM background-current drift, two common interferents encountered with FSCV at a CFM in vivo. Further, the DSP unit directly links the chemically resolved dopamine levels to the activation of the electrical microstimulator in on-off-keying (OOK) fashion. Measured results from benchtop testing, flow injection analysis (FIA), and biological experiments with an anesthetized rat are presented.","abstract_has_math":false,"creators":["Bozorgzadeh, Bardia"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mohseni, Pedram"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-03","date_published":"2015-09-03","updated_at":"2026-11-27T04:40:27Z","subjects":["Electrical Engineering","chemometrics, closed-loop neuromodulation, digital signal processor, dopamine regulation, fast-scan cyclic voltammetry, interferent differentiation, neurochemical sensing, pattern generation, principal component regression, system-on-chip"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1432223568","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1432223568","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1432223568","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1432223568","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mohseni, Pedram"]},{"key":"dc:creator","label":"Author","values":["Bozorgzadeh, Bardia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-03"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","chemometrics, closed-loop neuromodulation, digital signal processor, dopamine regulation, fast-scan cyclic voltammetry, interferent differentiation, neurochemical sensing, pattern generation, principal component regression, system-on-chip"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1432223568"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This project has developed two integrated microsystems fabricated in a 0.35-µm two-poly four-metal CMOS process for high-fidelity sensing and manipulation of brain neurochemistry. In particular, first, a system-on-chip (SoC) has been developed for neurochemical pattern generation <i>in vivo</i>. This SoC uniquely integrates electrical stimulation with embedded timing management for generation of neurochemical patterns and 400V/s fast-scan cyclic voltammetry (FSCV) sensing at a carbon-fiber microelectrode (CFM), for subsequent assessment of fidelity in the generated profiles, and manages a novel switched-electrode scheme that eliminates the possibility of large stimulus artifacts adversely affecting electrochemistry. The SoC also leverages the discontinuous sampling inherent in FSCV to reduce the sensing power consumption by 87.5% to 9.3µW from 2.5V using a duty-cycled, 3rd-order, continuous-time, delta-sigma modulator (CT-ΔΣM) with an input-referred noise current of 78pA<sub>rms</sub> (dc – 5 kHz) within an input current range of ±950nA. Utilizing a transfer function that relates electrical stimulation of dopamine axons traversing the medial forebrain bundle (MFB) to evoked extracellular dopamine dynamics in the dorsal striatum of the forebrain, the correlation coefficient between predicted and measured dopamine temporal profiles was found to be 0.95 in an anesthetized rat.Next, the second SoC has been developed for closed-loop regulation of brain dopamine. This SoC uniquely integrates neurochemical sensing, on-the-fly chemometrics, and feedback-controlled electrical microstimulation to mimic a “neurochemical thermostat” by maintaining brain levels of electrically evoked dopamine between two user-set thresholds. The SoC incorporates a 90µW, custom-designed, digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by 400V/s FSCV at a CFM. Specifically, the DSP unit executes a chemometrics algorithm based upon principal component regression (PCR) to resolve in real time electrically evoked brain dopamine levels from pH change and CFM background-current drift, two common interferents encountered with FSCV at a CFM in vivo. Further, the DSP unit directly links the chemically resolved dopamine levels to the activation of the electrical microstimulator in on-off-keying (OOK) fashion. Measured results from benchtop testing, flow injection analysis (FIA), and biological experiments with an anesthetized rat are presented."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.124","16.48 MB"]},{"key":"dc:title","label":"Title","values":["Integrated Microsystems for High-Fidelity Sensing and Manipulation of Brain Neurochemistry"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mohseni, Pedram"],"dc:creator":["Bozorgzadeh, Bardia"],"dc:date":["2015-09-03"],"dc:description":["This project has developed two integrated microsystems fabricated in a 0.35-µm two-poly four-metal CMOS process for high-fidelity sensing and manipulation of brain neurochemistry. In particular, first, a system-on-chip (SoC) has been developed for neurochemical pattern generation <i>in vivo</i>. This SoC uniquely integrates electrical stimulation with embedded timing management for generation of neurochemical patterns and 400V/s fast-scan cyclic voltammetry (FSCV) sensing at a carbon-fiber microelectrode (CFM), for subsequent assessment of fidelity in the generated profiles, and manages a novel switched-electrode scheme that eliminates the possibility of large stimulus artifacts adversely affecting electrochemistry. The SoC also leverages the discontinuous sampling inherent in FSCV to reduce the sensing power consumption by 87.5% to 9.3µW from 2.5V using a duty-cycled, 3rd-order, continuous-time, delta-sigma modulator (CT-ΔΣM) with an input-referred noise current of 78pA<sub>rms</sub> (dc – 5 kHz) within an input current range of ±950nA. Utilizing a transfer function that relates electrical stimulation of dopamine axons traversing the medial forebrain bundle (MFB) to evoked extracellular dopamine dynamics in the dorsal striatum of the forebrain, the correlation coefficient between predicted and measured dopamine temporal profiles was found to be 0.95 in an anesthetized rat.Next, the second SoC has been developed for closed-loop regulation of brain dopamine. This SoC uniquely integrates neurochemical sensing, on-the-fly chemometrics, and feedback-controlled electrical microstimulation to mimic a “neurochemical thermostat” by maintaining brain levels of electrically evoked dopamine between two user-set thresholds. The SoC incorporates a 90µW, custom-designed, digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by 400V/s FSCV at a CFM. Specifically, the DSP unit executes a chemometrics algorithm based upon principal component regression (PCR) to resolve in real time electrically evoked brain dopamine levels from pH change and CFM background-current drift, two common interferents encountered with FSCV at a CFM in vivo. Further, the DSP unit directly links the chemically resolved dopamine levels to the activation of the electrical microstimulator in on-off-keying (OOK) fashion. Measured results from benchtop testing, flow injection analysis (FIA), and biological experiments with an anesthetized rat are presented."],"dc:format":["application/pdf","p.124","16.48 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1432223568"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","chemometrics, closed-loop neuromodulation, digital signal processor, dopamine regulation, fast-scan cyclic voltammetry, interferent differentiation, neurochemical sensing, pattern generation, principal component regression, system-on-chip"],"dc:title":["Integrated Microsystems for High-Fidelity Sensing and Manipulation of Brain Neurochemistry"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:27Z"}