{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1432226195"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1432226195","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An Energy-Efficient Impulse Radio Ultra Wideband (IR-UWB) Transceiver for High-Rate Biotelemetry","abstract":"This project has developed an energy-efficient, high data-rate, impulse radio ultra wideband (IR-UWB) transceiver, operating in three channels within 3–5 GHz for centimeter-to-meter range biotelemetry. Fabricated in 90 nm 1P/9M CMOS, the transceiver integrates an all-digital transmitter with a waveform-synthesis pulse generator and a timing generator for pulse modulation and phase scrambling that, as well as a noncoherent receiver with front-end RF amplification/filtering, self-correlation for energy detection and digital synchronization of the baseband clock and data. The transmitter provides great flexibility in reconfiguring the UWB pulse waveform in the time domain (e.g., overall shape, amplitude, duration) as well as its power spectral density (PSD) in the frequency domain (e.g., center frequency, bandwidth, peak level). A fully integrated receiver would also significantly reduce its power consumption as compared to that of a discrete implementation, addressing another limitation for true portability of the centimeter-range transceiver and greatly enhancing energy efficiency per received bit in the wireless link. The receiver RF front-end can provide up to 37 dB of gain with adjustable bandwidth, sharp roll-off and tunable center frequency at 3.5, 4 and 4.5 GHz for channel selection and robustness against out-of-band noise/interference.Employing a miniaturized, UWB, chip antenna for the transmitter and receiver, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 75 Mb/s over 10 cm–1 m is shown for portable application. Further, employing a high gain horn antenna for the receiver, wireless transmission of PRBS data at rates up to 125 Mb/s over 50 cm–4 m is shown for stationary application with transmitter and receiver energy consumption of 14 pJ/pulse and 0.15 nJ/b, respectively, from 1.2 V. To address the problem of data rate in high-channel-count neurochemical monitoring, we demonstrated proof-of-concept feasibility of utilizing IR-UWB signaling technique for wireless transmission of dopamine concentrations levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), and compares the results with those obtained by using a conventional frequency-shift-keyed (FSK) transceiver as the uplink.","abstract_html":"This project has developed an energy-efficient, high data-rate, impulse radio ultra wideband (IR-UWB) transceiver, operating in three channels within 3–5 GHz for centimeter-to-meter range biotelemetry. Fabricated in 90 nm 1P/9M CMOS, the transceiver integrates an all-digital transmitter with a waveform-synthesis pulse generator and a timing generator for pulse modulation and phase scrambling that, as well as a noncoherent receiver with front-end RF amplification/filtering, self-correlation for energy detection and digital synchronization of the baseband clock and data. The transmitter provides great flexibility in reconfiguring the UWB pulse waveform in the time domain (e.g., overall shape, amplitude, duration) as well as its power spectral density (PSD) in the frequency domain (e.g., center frequency, bandwidth, peak level). A fully integrated receiver would also significantly reduce its power consumption as compared to that of a discrete implementation, addressing another limitation for true portability of the centimeter-range transceiver and greatly enhancing energy efficiency per received bit in the wireless link. The receiver RF front-end can provide up to 37 dB of gain with adjustable bandwidth, sharp roll-off and tunable center frequency at 3.5, 4 and 4.5 GHz for channel selection and robustness against out-of-band noise/interference.Employing a miniaturized, UWB, chip antenna for the transmitter and receiver, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 75 Mb/s over 10 cm–1 m is shown for portable application. Further, employing a high gain horn antenna for the receiver, wireless transmission of PRBS data at rates up to 125 Mb/s over 50 cm–4 m is shown for stationary application with transmitter and receiver energy consumption of 14 pJ/pulse and 0.15 nJ/b, respectively, from 1.2 V. To address the problem of data rate in high-channel-count neurochemical monitoring, we demonstrated proof-of-concept feasibility of utilizing IR-UWB signaling technique for wireless transmission of dopamine concentrations levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), and compares the results with those obtained by using a conventional frequency-shift-keyed (FSK) transceiver as the uplink.","abstract_has_math":false,"creators":["Ebrazeh, Ali"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mohseni, Pedram"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-03","date_published":"2015-09-03","updated_at":"2026-11-27T04:40:27Z","subjects":["Electrical Engineering","Biomedical Engineering","centimeter-to-meter range biotelemetry, channelized operation, energy-efficient transceiver, high data-rate transceiver, IR-UWB receiver, IR-UWB transmitter, out-of-band interference robustness, UWB pulse generator, waveform synthesis, wireless link"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1432226195","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1432226195","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1432226195","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1432226195","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mohseni, Pedram"]},{"key":"dc:creator","label":"Author","values":["Ebrazeh, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-03"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Biomedical Engineering","centimeter-to-meter range biotelemetry, channelized operation, energy-efficient transceiver, high data-rate transceiver, IR-UWB receiver, IR-UWB transmitter, out-of-band interference robustness, UWB pulse generator, waveform synthesis, wireless link"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1432226195"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This project has developed an energy-efficient, high data-rate, impulse radio ultra wideband (IR-UWB) transceiver, operating in three channels within 3–5 GHz for centimeter-to-meter range biotelemetry. Fabricated in 90 nm 1P/9M CMOS, the transceiver integrates an all-digital transmitter with a waveform-synthesis pulse generator and a timing generator for pulse modulation and phase scrambling that, as well as a noncoherent receiver with front-end RF amplification/filtering, self-correlation for energy detection and digital synchronization of the baseband clock and data. The transmitter provides great flexibility in reconfiguring the UWB pulse waveform in the time domain (e.g., overall shape, amplitude, duration) as well as its power spectral density (PSD) in the frequency domain (e.g., center frequency, bandwidth, peak level). A fully integrated receiver would also significantly reduce its power consumption as compared to that of a discrete implementation, addressing another limitation for true portability of the centimeter-range transceiver and greatly enhancing energy efficiency per received bit in the wireless link. The receiver RF front-end can provide up to 37 dB of gain with adjustable bandwidth, sharp roll-off and tunable center frequency at 3.5, 4 and 4.5 GHz for channel selection and robustness against out-of-band noise/interference.Employing a miniaturized, UWB, chip antenna for the transmitter and receiver, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 75 Mb/s over 10 cm–1 m is shown for portable application. Further, employing a high gain horn antenna for the receiver, wireless transmission of PRBS data at rates up to 125 Mb/s over 50 cm–4 m is shown for stationary application with transmitter and receiver energy consumption of 14 pJ/pulse and 0.15 nJ/b, respectively, from 1.2 V. To address the problem of data rate in high-channel-count neurochemical monitoring, we demonstrated proof-of-concept feasibility of utilizing IR-UWB signaling technique for wireless transmission of dopamine concentrations levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), and compares the results with those obtained by using a conventional frequency-shift-keyed (FSK) transceiver as the uplink."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.132","14.36 MB"]},{"key":"dc:title","label":"Title","values":["An Energy-Efficient Impulse Radio Ultra Wideband (IR-UWB) Transceiver for High-Rate Biotelemetry"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mohseni, Pedram"],"dc:creator":["Ebrazeh, Ali"],"dc:date":["2015-09-03"],"dc:description":["This project has developed an energy-efficient, high data-rate, impulse radio ultra wideband (IR-UWB) transceiver, operating in three channels within 3–5 GHz for centimeter-to-meter range biotelemetry. Fabricated in 90 nm 1P/9M CMOS, the transceiver integrates an all-digital transmitter with a waveform-synthesis pulse generator and a timing generator for pulse modulation and phase scrambling that, as well as a noncoherent receiver with front-end RF amplification/filtering, self-correlation for energy detection and digital synchronization of the baseband clock and data. The transmitter provides great flexibility in reconfiguring the UWB pulse waveform in the time domain (e.g., overall shape, amplitude, duration) as well as its power spectral density (PSD) in the frequency domain (e.g., center frequency, bandwidth, peak level). A fully integrated receiver would also significantly reduce its power consumption as compared to that of a discrete implementation, addressing another limitation for true portability of the centimeter-range transceiver and greatly enhancing energy efficiency per received bit in the wireless link. The receiver RF front-end can provide up to 37 dB of gain with adjustable bandwidth, sharp roll-off and tunable center frequency at 3.5, 4 and 4.5 GHz for channel selection and robustness against out-of-band noise/interference.Employing a miniaturized, UWB, chip antenna for the transmitter and receiver, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 75 Mb/s over 10 cm–1 m is shown for portable application. Further, employing a high gain horn antenna for the receiver, wireless transmission of PRBS data at rates up to 125 Mb/s over 50 cm–4 m is shown for stationary application with transmitter and receiver energy consumption of 14 pJ/pulse and 0.15 nJ/b, respectively, from 1.2 V. To address the problem of data rate in high-channel-count neurochemical monitoring, we demonstrated proof-of-concept feasibility of utilizing IR-UWB signaling technique for wireless transmission of dopamine concentrations levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), and compares the results with those obtained by using a conventional frequency-shift-keyed (FSK) transceiver as the uplink."],"dc:format":["application/pdf","p.132","14.36 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1432226195"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Biomedical Engineering","centimeter-to-meter range biotelemetry, channelized operation, energy-efficient transceiver, high data-rate transceiver, IR-UWB receiver, IR-UWB transmitter, out-of-band interference robustness, UWB pulse generator, waveform synthesis, wireless link"],"dc:title":["An Energy-Efficient Impulse Radio Ultra Wideband (IR-UWB) Transceiver for High-Rate Biotelemetry"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:27Z"}