{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1440685144"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1440685144","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DEVELOPE OF ULTRASOUND ELASTOGRAPHY FOR NONDESTRUCTIVE AND NONINVASIVE CHARACTERIZATION OF STIFFER POLYMERIC BIOMATERIALS","abstract":"Significant advancements in biodegradable polymeric materials have been made for numerous applications including tissue engineering, regenerative medicine and drug delivery. The functions of these polymers within each application often rely on controllable polymer degradation and erosion, yet the process has proven difficult to measure in vivo. Traditional methods for investigating polymer erosion and degradation are destructive, hampering accurate longitudinal measurement of the samples in the same subject. To overcome this limitation we have explored the use of ultrasound elastography imaging as a tool to nondestructively measure strain of poly(lactic-co-glycolic acid) (PLGA) phase sensitive in situ forming implants which changes with progressive loss of structural integrity resulting from polymer erosion. In order to better employ this technology, ultrasound elastography imaging was first characterized and validated by comparing to the gold standard unconfined compression testing of PDMS samples with different Young’s moduli. The detection limit as well as detectable difference of this technique were identified. This imaging system was also optimized to scan stiffer polymeric biomaterials. Using this tool, we investigated erosion kinetics of implants comprised of three different PLGA molecular weights in vitro and in vivo. The in vitro environment was created using a novel polyacrylamide based tissue mimicking phantom while the in vivo experiment was performed subcutaneously using a rat abdominal model. A strong linear relationship independent of polymer molecular weight was found between average strain values and erosion values in both the in vitro and in vivo environment. Results support the use of a mechanical stiffness based predicative model for longitudinal monitoring of material erosion and highlight the use of ultrasound elastography as a nondestructive tool for measuring polymer erosion kinetics.","abstract_html":"Significant advancements in biodegradable polymeric materials have been made for numerous applications including tissue engineering, regenerative medicine and drug delivery. The functions of these polymers within each application often rely on controllable polymer degradation and erosion, yet the process has proven difficult to measure in vivo. Traditional methods for investigating polymer erosion and degradation are destructive, hampering accurate longitudinal measurement of the samples in the same subject. To overcome this limitation we have explored the use of ultrasound elastography imaging as a tool to nondestructively measure strain of poly(lactic-co-glycolic acid) (PLGA) phase sensitive in situ forming implants which changes with progressive loss of structural integrity resulting from polymer erosion. In order to better employ this technology, ultrasound elastography imaging was first characterized and validated by comparing to the gold standard unconfined compression testing of PDMS samples with different Young’s moduli. The detection limit as well as detectable difference of this technique were identified. This imaging system was also optimized to scan stiffer polymeric biomaterials. Using this tool, we investigated erosion kinetics of implants comprised of three different PLGA molecular weights in vitro and in vivo. The in vitro environment was created using a novel polyacrylamide based tissue mimicking phantom while the in vivo experiment was performed subcutaneously using a rat abdominal model. A strong linear relationship independent of polymer molecular weight was found between average strain values and erosion values in both the in vitro and in vivo environment. Results support the use of a mechanical stiffness based predicative model for longitudinal monitoring of material erosion and highlight the use of ultrasound elastography as a nondestructive tool for measuring polymer erosion kinetics.","abstract_has_math":false,"creators":["Haoyan, Zhou, United States"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Exner, Agata"],"committee_chairs":["von Recum, Horst"],"committee_members":[],"year":2016,"date_issued":"2016-01-27","date_published":"2016-01-27","updated_at":"2026-11-27T04:40:38Z","subjects":["Biomedical Engineering","Biomedical Research","Polymers","Noninvasive, Non-destructive, characterization, polymer, biomaterials, ultrasound, elastography, erosion, degradation, PLGA and mechanical"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1440685144","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1440685144","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1440685144","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1440685144","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Exner, Agata"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["von Recum, Horst"]},{"key":"dc:creator","label":"Author","values":["Haoyan, Zhou, United States"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-01-27"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Polymers","Noninvasive, Non-destructive, characterization, polymer, biomaterials, ultrasound, elastography, erosion, degradation, PLGA and mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1440685144"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Significant advancements in biodegradable polymeric materials have been made for numerous applications including tissue engineering, regenerative medicine and drug delivery. The functions of these polymers within each application often rely on controllable polymer degradation and erosion, yet the process has proven difficult to measure in vivo. Traditional methods for investigating polymer erosion and degradation are destructive, hampering accurate longitudinal measurement of the samples in the same subject. To overcome this limitation we have explored the use of ultrasound elastography imaging as a tool to nondestructively measure strain of poly(lactic-co-glycolic acid) (PLGA) phase sensitive in situ forming implants which changes with progressive loss of structural integrity resulting from polymer erosion. In order to better employ this technology, ultrasound elastography imaging was first characterized and validated by comparing to the gold standard unconfined compression testing of PDMS samples with different Young’s moduli. The detection limit as well as detectable difference of this technique were identified. This imaging system was also optimized to scan stiffer polymeric biomaterials. Using this tool, we investigated erosion kinetics of implants comprised of three different PLGA molecular weights in vitro and in vivo. The in vitro environment was created using a novel polyacrylamide based tissue mimicking phantom while the in vivo experiment was performed subcutaneously using a rat abdominal model. A strong linear relationship independent of polymer molecular weight was found between average strain values and erosion values in both the in vitro and in vivo environment. Results support the use of a mechanical stiffness based predicative model for longitudinal monitoring of material erosion and highlight the use of ultrasound elastography as a nondestructive tool for measuring polymer erosion kinetics."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.160","3.18 MB"]},{"key":"dc:title","label":"Title","values":["DEVELOPE OF ULTRASOUND ELASTOGRAPHY FOR NONDESTRUCTIVE AND NONINVASIVE CHARACTERIZATION OF STIFFER POLYMERIC BIOMATERIALS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Exner, Agata"],"dc:contributor.committeechair":["von Recum, Horst"],"dc:creator":["Haoyan, Zhou, United States"],"dc:date":["2016-01-27"],"dc:description":["Significant advancements in biodegradable polymeric materials have been made for numerous applications including tissue engineering, regenerative medicine and drug delivery. The functions of these polymers within each application often rely on controllable polymer degradation and erosion, yet the process has proven difficult to measure in vivo. Traditional methods for investigating polymer erosion and degradation are destructive, hampering accurate longitudinal measurement of the samples in the same subject. To overcome this limitation we have explored the use of ultrasound elastography imaging as a tool to nondestructively measure strain of poly(lactic-co-glycolic acid) (PLGA) phase sensitive in situ forming implants which changes with progressive loss of structural integrity resulting from polymer erosion. In order to better employ this technology, ultrasound elastography imaging was first characterized and validated by comparing to the gold standard unconfined compression testing of PDMS samples with different Young’s moduli. The detection limit as well as detectable difference of this technique were identified. This imaging system was also optimized to scan stiffer polymeric biomaterials. Using this tool, we investigated erosion kinetics of implants comprised of three different PLGA molecular weights in vitro and in vivo. The in vitro environment was created using a novel polyacrylamide based tissue mimicking phantom while the in vivo experiment was performed subcutaneously using a rat abdominal model. A strong linear relationship independent of polymer molecular weight was found between average strain values and erosion values in both the in vitro and in vivo environment. Results support the use of a mechanical stiffness based predicative model for longitudinal monitoring of material erosion and highlight the use of ultrasound elastography as a nondestructive tool for measuring polymer erosion kinetics."],"dc:format":["application/pdf","p.160","3.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1440685144"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Polymers","Noninvasive, Non-destructive, characterization, polymer, biomaterials, ultrasound, elastography, erosion, degradation, PLGA and mechanical"],"dc:title":["DEVELOPE OF ULTRASOUND ELASTOGRAPHY FOR NONDESTRUCTIVE AND NONINVASIVE CHARACTERIZATION OF STIFFER POLYMERIC BIOMATERIALS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:38Z"}