{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1446477944"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1446477944","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"ENERGY EFFICIENCY AND STATISTICAL ANALYSIS OF BUILDINGS AT CASE WESTERN RESERVE UNIVERSITY","abstract":"Statistical and energy modeling techniques were applied to various buildings on the campus of Case Western Reserve University to diagnose energy efficiency issues in buildings. The computing code, R, was used for the statistical analysis on building energy consumption data and associated weather data. Together with this analysis, a thermal model was applied to obtain R-values and thermal mass values for the buildings. The R-values provide insight to the insulation and infiltration characteristics of the building. These values are similar in magnitude to R-values determined from other studies [1]. The thermal mass provides insight to the transient behavior of buildings, which can help one understand how to take advantage of transient temperature fluctuations to the benefit of energy savings. The values obtained were determined to fall within a reasonable range when using the steam (i.e. heating) data for the calculation. In summary, the combined statistical and theoretical analysis applied demonstrate that keen insight can be obtained about potential energy efficiency problems and opportunities without setting foot in a building","abstract_html":"Statistical and energy modeling techniques were applied to various buildings on the campus of Case Western Reserve University to diagnose energy efficiency issues in buildings. The computing code, R, was used for the statistical analysis on building energy consumption data and associated weather data. Together with this analysis, a thermal model was applied to obtain R-values and thermal mass values for the buildings. The R-values provide insight to the insulation and infiltration characteristics of the building. These values are similar in magnitude to R-values determined from other studies [1]. The thermal mass provides insight to the transient behavior of buildings, which can help one understand how to take advantage of transient temperature fluctuations to the benefit of energy savings. The values obtained were determined to fall within a reasonable range when using the steam (i.e. heating) data for the calculation. In summary, the combined statistical and theoretical analysis applied demonstrate that keen insight can be obtained about potential energy efficiency problems and opportunities without setting foot in a building","abstract_has_math":false,"creators":["Hung, Aaron"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":["Abramson, Alexis"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-26T05:26:32Z","subjects":["Engineering","Mechanical Engineering","Building Energy","Data Analysis","R-Value","Thermal Mass"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1446477944","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1446477944","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1446477944","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1446477944","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Abramson, Alexis"]},{"key":"dc:creator","label":"Author","values":["Hung, Aaron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering","Building Energy","Data Analysis","R-Value","Thermal Mass"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1446477944"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Statistical and energy modeling techniques were applied to various buildings on the campus of Case Western Reserve University to diagnose energy efficiency issues in buildings. The computing code, R, was used for the statistical analysis on building energy consumption data and associated weather data. Together with this analysis, a thermal model was applied to obtain R-values and thermal mass values for the buildings. The R-values provide insight to the insulation and infiltration characteristics of the building. These values are similar in magnitude to R-values determined from other studies [1]. The thermal mass provides insight to the transient behavior of buildings, which can help one understand how to take advantage of transient temperature fluctuations to the benefit of energy savings. The values obtained were determined to fall within a reasonable range when using the steam (i.e. heating) data for the calculation. In summary, the combined statistical and theoretical analysis applied demonstrate that keen insight can be obtained about potential energy efficiency problems and opportunities without setting foot in a building"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.73","1.57 MB"]},{"key":"dc:title","label":"Title","values":["ENERGY EFFICIENCY AND STATISTICAL ANALYSIS OF BUILDINGS AT CASE WESTERN RESERVE UNIVERSITY"]}]}],"canonical_facts":{"dc:contributor":["Abramson, Alexis"],"dc:creator":["Hung, Aaron"],"dc:date":["2015"],"dc:description":["Statistical and energy modeling techniques were applied to various buildings on the campus of Case Western Reserve University to diagnose energy efficiency issues in buildings. The computing code, R, was used for the statistical analysis on building energy consumption data and associated weather data. Together with this analysis, a thermal model was applied to obtain R-values and thermal mass values for the buildings. The R-values provide insight to the insulation and infiltration characteristics of the building. These values are similar in magnitude to R-values determined from other studies [1]. The thermal mass provides insight to the transient behavior of buildings, which can help one understand how to take advantage of transient temperature fluctuations to the benefit of energy savings. The values obtained were determined to fall within a reasonable range when using the steam (i.e. heating) data for the calculation. In summary, the combined statistical and theoretical analysis applied demonstrate that keen insight can be obtained about potential energy efficiency problems and opportunities without setting foot in a building"],"dc:format":["application/pdf","p.73","1.57 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1446477944"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Mechanical Engineering","Building Energy","Data Analysis","R-Value","Thermal Mass"],"dc:title":["ENERGY EFFICIENCY AND STATISTICAL ANALYSIS OF BUILDINGS AT CASE WESTERN RESERVE UNIVERSITY"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T05:26:32Z"}