{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1453880114"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1453880114","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MEASUREMENT OF J-INTEGRAL VALUES OF DENTAL CERAMICS BY DIGITAL IMAGE CORRELATION","abstract":"J-integral can be used to characterize the crack initiation and propagation process and requires a smaller sample dimensions compare to stress intensity factor (SIF) based test. Yet no studies have investigated the J-integral of dental restoration materials. The aim of this study is to measure J-integral value for dental restoration materials with Digital Image Correlation (DIC) method. Three materials (IPS E-MAX, Vita Mark II and Paradigm MZ100) are used to prepare beam samples for three-point bending test. And a finite element model of VM II was built to validate the strain accuracy of DIC. The critical SIF are then calculated from J-integral (KJ ) and compared with the ones calculated from geometry dimensions and load at fracture (KIC). Generally KIChas a higher value than KJ . Yet there is a good consistency between KJ and KIC , thus proving DIC is an effective way to obtain J-integral for dental restoration materials.","abstract_html":"J-integral can be used to characterize the crack initiation and propagation process and requires a smaller sample dimensions compare to stress intensity factor (SIF) based test. Yet no studies have investigated the J-integral of dental restoration materials. The aim of this study is to measure J-integral value for dental restoration materials with Digital Image Correlation (DIC) method. Three materials (IPS E-MAX, Vita Mark II and Paradigm MZ100) are used to prepare beam samples for three-point bending test. And a finite element model of VM II was built to validate the strain accuracy of DIC. The critical SIF are then calculated from J-integral (KJ ) and compared with the ones calculated from geometry dimensions and load at fracture (KIC). Generally KIChas a higher value than KJ . Yet there is a good consistency between KJ and KIC , thus proving DIC is an effective way to obtain J-integral for dental restoration materials.","abstract_has_math":false,"creators":["Jiang, Yanxia"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Akkus, Ozan"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05-30","date_published":"2016-05-30","updated_at":"2026-11-27T04:40:52Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1453880114","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1453880114","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1453880114","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1453880114","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Akkus, Ozan"]},{"key":"dc:creator","label":"Author","values":["Jiang, Yanxia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1453880114"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["J-integral can be used to characterize the crack initiation and propagation process and requires a smaller sample dimensions compare to stress intensity factor (SIF) based test. Yet no studies have investigated the J-integral of dental restoration materials. The aim of this study is to measure J-integral value for dental restoration materials with Digital Image Correlation (DIC) method. Three materials (IPS E-MAX, Vita Mark II and Paradigm MZ100) are used to prepare beam samples for three-point bending test. And a finite element model of VM II was built to validate the strain accuracy of DIC. The critical SIF are then calculated from J-integral (KJ ) and compared with the ones calculated from geometry dimensions and load at fracture (KIC). Generally KIChas a higher value than KJ . Yet there is a good consistency between KJ and KIC , thus proving DIC is an effective way to obtain J-integral for dental restoration materials."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.52 MB"]},{"key":"dc:title","label":"Title","values":["MEASUREMENT OF J-INTEGRAL VALUES OF DENTAL CERAMICS BY DIGITAL IMAGE CORRELATION"]}]}],"canonical_facts":{"dc:contributor.advisor":["Akkus, Ozan"],"dc:creator":["Jiang, Yanxia"],"dc:date":["2016-05-30"],"dc:description":["J-integral can be used to characterize the crack initiation and propagation process and requires a smaller sample dimensions compare to stress intensity factor (SIF) based test. Yet no studies have investigated the J-integral of dental restoration materials. The aim of this study is to measure J-integral value for dental restoration materials with Digital Image Correlation (DIC) method. Three materials (IPS E-MAX, Vita Mark II and Paradigm MZ100) are used to prepare beam samples for three-point bending test. And a finite element model of VM II was built to validate the strain accuracy of DIC. The critical SIF are then calculated from J-integral (KJ ) and compared with the ones calculated from geometry dimensions and load at fracture (KIC). Generally KIChas a higher value than KJ . Yet there is a good consistency between KJ and KIC , thus proving DIC is an effective way to obtain J-integral for dental restoration materials."],"dc:format":["application/pdf","2.52 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1453880114"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Mechanical Engineering"],"dc:title":["MEASUREMENT OF J-INTEGRAL VALUES OF DENTAL CERAMICS BY DIGITAL IMAGE CORRELATION"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:52Z"}