{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1459969270"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1459969270","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Detection of Journal Bearing Cavitation with Use of Ultrasound Technology","abstract":"A method utilizing the implementation of ultrasound technology is developed to detect cavitation in an operating journal bearing. A modified Reynolds equation is derived and applied to a journal bearing design in order to determine the pressure distribution of the fluid film present in the bearing during operation. This model is used to predict the location of the low pressure region, or gaseous cavitation region, of the bearing to determine the target location for the ultrasound technology instrumentation. A journal bearing test bench apparatus was constructed under the guidance of the pressure distribution model. Ultrasound technology in the form of a small 7mm diameter 10MHz sensor is applied to the back side of the fabricated bearing, opposite of the predicted low fluid film pressure region of bearing operation. An experiment is conducted in order to compare the ultrasound signal attenuation when the measurement region is exposed to both high and low fluid film pressures. The results of the experimental testing indicate a correlation of the ultrasound signal response with whether the measurement region is exposed to high or low fluid film pressures from journal operation. Correlation of changes in signal attenuation with cavitation located in the low fluid film pressure region present itself as an increase in signal attenuation variability when compared to the signal measured in high fluid film pressure regions. The presence of gaseous cavities in the low fluid film pressure region is confirmed with the fabrication and operation of a translucent bearing of identical geometries. Cavities in the fluid film are observed in the low pressure region during operation of the translucent bearing, validating the presence of cavitation in the target region, further confirming the ability of the technique to detect cavitation in journal bearing operation.","abstract_html":"A method utilizing the implementation of ultrasound technology is developed to detect cavitation in an operating journal bearing. A modified Reynolds equation is derived and applied to a journal bearing design in order to determine the pressure distribution of the fluid film present in the bearing during operation. This model is used to predict the location of the low pressure region, or gaseous cavitation region, of the bearing to determine the target location for the ultrasound technology instrumentation. A journal bearing test bench apparatus was constructed under the guidance of the pressure distribution model. Ultrasound technology in the form of a small 7mm diameter 10MHz sensor is applied to the back side of the fabricated bearing, opposite of the predicted low fluid film pressure region of bearing operation. An experiment is conducted in order to compare the ultrasound signal attenuation when the measurement region is exposed to both high and low fluid film pressures. The results of the experimental testing indicate a correlation of the ultrasound signal response with whether the measurement region is exposed to high or low fluid film pressures from journal operation. Correlation of changes in signal attenuation with cavitation located in the low fluid film pressure region present itself as an increase in signal attenuation variability when compared to the signal measured in high fluid film pressure regions. The presence of gaseous cavities in the low fluid film pressure region is confirmed with the fabrication and operation of a translucent bearing of identical geometries. Cavities in the fluid film are observed in the low pressure region during operation of the translucent bearing, validating the presence of cavitation in the target region, further confirming the ability of the technique to detect cavitation in journal bearing operation.","abstract_has_math":false,"creators":["Miranda, Gregorio do Couto"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":["Prahl, Joseph"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05-31","date_published":"2016-05-31","updated_at":"2026-11-26T05:28:11Z","subjects":["Mechanical Engineering","Fluid Dynamics","Cavitation Detection, Ultrasound, Journal Bearing, Hydrodynamic Bearing, Lubrication, Tribology, Vaporous Cavitation, Gaseous Cavitation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1459969270","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1459969270","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1459969270","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1459969270","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Prahl, Joseph"]},{"key":"dc:creator","label":"Author","values":["Miranda, Gregorio do Couto"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-31"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Fluid Dynamics","Cavitation Detection, Ultrasound, Journal Bearing, Hydrodynamic Bearing, Lubrication, Tribology, Vaporous Cavitation, Gaseous Cavitation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1459969270"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A method utilizing the implementation of ultrasound technology is developed to detect cavitation in an operating journal bearing. A modified Reynolds equation is derived and applied to a journal bearing design in order to determine the pressure distribution of the fluid film present in the bearing during operation. This model is used to predict the location of the low pressure region, or gaseous cavitation region, of the bearing to determine the target location for the ultrasound technology instrumentation. A journal bearing test bench apparatus was constructed under the guidance of the pressure distribution model. Ultrasound technology in the form of a small 7mm diameter 10MHz sensor is applied to the back side of the fabricated bearing, opposite of the predicted low fluid film pressure region of bearing operation. An experiment is conducted in order to compare the ultrasound signal attenuation when the measurement region is exposed to both high and low fluid film pressures. The results of the experimental testing indicate a correlation of the ultrasound signal response with whether the measurement region is exposed to high or low fluid film pressures from journal operation. Correlation of changes in signal attenuation with cavitation located in the low fluid film pressure region present itself as an increase in signal attenuation variability when compared to the signal measured in high fluid film pressure regions. The presence of gaseous cavities in the low fluid film pressure region is confirmed with the fabrication and operation of a translucent bearing of identical geometries. Cavities in the fluid film are observed in the low pressure region during operation of the translucent bearing, validating the presence of cavitation in the target region, further confirming the ability of the technique to detect cavitation in journal bearing operation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.145","6.12 MB"]},{"key":"dc:title","label":"Title","values":["The Detection of Journal Bearing Cavitation with Use of Ultrasound Technology"]}]}],"canonical_facts":{"dc:contributor":["Prahl, Joseph"],"dc:creator":["Miranda, Gregorio do Couto"],"dc:date":["2016-05-31"],"dc:description":["A method utilizing the implementation of ultrasound technology is developed to detect cavitation in an operating journal bearing. A modified Reynolds equation is derived and applied to a journal bearing design in order to determine the pressure distribution of the fluid film present in the bearing during operation. This model is used to predict the location of the low pressure region, or gaseous cavitation region, of the bearing to determine the target location for the ultrasound technology instrumentation. A journal bearing test bench apparatus was constructed under the guidance of the pressure distribution model. Ultrasound technology in the form of a small 7mm diameter 10MHz sensor is applied to the back side of the fabricated bearing, opposite of the predicted low fluid film pressure region of bearing operation. An experiment is conducted in order to compare the ultrasound signal attenuation when the measurement region is exposed to both high and low fluid film pressures. The results of the experimental testing indicate a correlation of the ultrasound signal response with whether the measurement region is exposed to high or low fluid film pressures from journal operation. Correlation of changes in signal attenuation with cavitation located in the low fluid film pressure region present itself as an increase in signal attenuation variability when compared to the signal measured in high fluid film pressure regions. The presence of gaseous cavities in the low fluid film pressure region is confirmed with the fabrication and operation of a translucent bearing of identical geometries. Cavities in the fluid film are observed in the low pressure region during operation of the translucent bearing, validating the presence of cavitation in the target region, further confirming the ability of the technique to detect cavitation in journal bearing operation."],"dc:format":["application/pdf","p.145","6.12 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1459969270"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Mechanical Engineering","Fluid Dynamics","Cavitation Detection, Ultrasound, Journal Bearing, Hydrodynamic Bearing, Lubrication, Tribology, Vaporous Cavitation, Gaseous Cavitation"],"dc:title":["The Detection of Journal Bearing Cavitation with Use of Ultrasound Technology"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T05:28:11Z"}