{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1462871978"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1462871978","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MICRO-GAS EXCHANGER FOR OXYGEN TENSION CONTROL IN BIOLOGICAL MICROFLUIDIC SYSTEMS","abstract":"Oxygen tension is a crucial element in physiologically relevant in vitro systems as cellular functions and behaviors are affected by oxygen tension. Often, hypoxic chambers and workstations, which are inconvenient for the user, have been used to control oxygen tension. The advancement of microfluidics has facilitated development of innovative devices to mimic physiological conditions such as oxygen tension. Soft-lithography-based microfluidic platforms have been widely utilized for their rapid prototyping capabilities and low-cost material requirements. However, these platforms pose critical shortcomings including labor-intensive fabrication processes. To overcome these challenges, a high-throughput, low-cost, single-use, clinically applicable, and easily implementable micro-gas exchanger integrated with a microfluidic chip is developed. With this system, a heterogeneity in individual sickle cell disease (SCD) patients’ response to hypoxia is observed in terms of increase in the number of adhered RBCs compared to normoxia. Furthermore, significant associations between SCD patients’ response to hypoxia and clinical phenotypes are found.","abstract_html":"Oxygen tension is a crucial element in physiologically relevant in vitro systems as cellular functions and behaviors are affected by oxygen tension. Often, hypoxic chambers and workstations, which are inconvenient for the user, have been used to control oxygen tension. The advancement of microfluidics has facilitated development of innovative devices to mimic physiological conditions such as oxygen tension. Soft-lithography-based microfluidic platforms have been widely utilized for their rapid prototyping capabilities and low-cost material requirements. However, these platforms pose critical shortcomings including labor-intensive fabrication processes. To overcome these challenges, a high-throughput, low-cost, single-use, clinically applicable, and easily implementable micro-gas exchanger integrated with a microfluidic chip is developed. With this system, a heterogeneity in individual sickle cell disease (SCD) patients’ response to hypoxia is observed in terms of increase in the number of adhered RBCs compared to normoxia. Furthermore, significant associations between SCD patients’ response to hypoxia and clinical phenotypes are found.","abstract_has_math":false,"creators":["Kim, Myeongseop"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":["Gurkan, Umut"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05-30","date_published":"2016-05-30","updated_at":"2026-11-26T05:29:22Z","subjects":["Mechanical Engineering","microfluidics, sickle cell disease, blood, hypoxia, oxygen tension"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1462871978","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1462871978","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1462871978","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1462871978","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gurkan, Umut"]},{"key":"dc:creator","label":"Author","values":["Kim, Myeongseop"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","microfluidics, sickle cell disease, blood, hypoxia, oxygen tension"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1462871978"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Oxygen tension is a crucial element in physiologically relevant in vitro systems as cellular functions and behaviors are affected by oxygen tension. Often, hypoxic chambers and workstations, which are inconvenient for the user, have been used to control oxygen tension. The advancement of microfluidics has facilitated development of innovative devices to mimic physiological conditions such as oxygen tension. Soft-lithography-based microfluidic platforms have been widely utilized for their rapid prototyping capabilities and low-cost material requirements. However, these platforms pose critical shortcomings including labor-intensive fabrication processes. To overcome these challenges, a high-throughput, low-cost, single-use, clinically applicable, and easily implementable micro-gas exchanger integrated with a microfluidic chip is developed. With this system, a heterogeneity in individual sickle cell disease (SCD) patients’ response to hypoxia is observed in terms of increase in the number of adhered RBCs compared to normoxia. Furthermore, significant associations between SCD patients’ response to hypoxia and clinical phenotypes are found."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.83","2.41 MB"]},{"key":"dc:title","label":"Title","values":["MICRO-GAS EXCHANGER FOR OXYGEN TENSION CONTROL IN BIOLOGICAL MICROFLUIDIC SYSTEMS"]}]}],"canonical_facts":{"dc:contributor":["Gurkan, Umut"],"dc:creator":["Kim, Myeongseop"],"dc:date":["2016-05-30"],"dc:description":["Oxygen tension is a crucial element in physiologically relevant in vitro systems as cellular functions and behaviors are affected by oxygen tension. Often, hypoxic chambers and workstations, which are inconvenient for the user, have been used to control oxygen tension. The advancement of microfluidics has facilitated development of innovative devices to mimic physiological conditions such as oxygen tension. Soft-lithography-based microfluidic platforms have been widely utilized for their rapid prototyping capabilities and low-cost material requirements. However, these platforms pose critical shortcomings including labor-intensive fabrication processes. To overcome these challenges, a high-throughput, low-cost, single-use, clinically applicable, and easily implementable micro-gas exchanger integrated with a microfluidic chip is developed. With this system, a heterogeneity in individual sickle cell disease (SCD) patients’ response to hypoxia is observed in terms of increase in the number of adhered RBCs compared to normoxia. Furthermore, significant associations between SCD patients’ response to hypoxia and clinical phenotypes are found."],"dc:format":["application/pdf","p.83","2.41 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1462871978"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","microfluidics, sickle cell disease, blood, hypoxia, oxygen tension"],"dc:title":["MICRO-GAS EXCHANGER FOR OXYGEN TENSION CONTROL IN BIOLOGICAL MICROFLUIDIC SYSTEMS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T05:29:22Z"}