{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1484654444253783"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1484654444253783","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A MAGNETICALLY-ACTUATED ROBOTIC CATHETER FOR ATRIAL FIBRILLATION ABLATION UNDER REAL-TIME MAGNETIC RESONANCE IMAGING GUIDANCE","abstract":"This thesis focuses on design, modeling, and analysis of a magnetically actuated robotic intravascular catheter for performing atrial fibrillation ablation under magnetic resonance imaging guidance. Specifically:A three dimensional deflection model of a steerable catheter in free space is proposed and experimentally validated using a hardware prototype. In the proposed method, the catheter is modeled as a series of finite segments. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using the beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter is derived. A Jacobian-based iterative inverse kinematics method for controlling the steerable catheter is presented. The repeatability and accuracy of the open-loop control of the catheter system performing complex geometric trajectories using this inverse kinematics method is experimentally evaluated. The proposed three dimensional kinematic model is extended to incorporate the catheter-surface contact by taking contact forces and torques into account. A systematic approach to the design optimization of a magnetically-actuated steerable catheter for atrial fibrillation ablation in the left atrium, is proposed. The study investigates the relationship between the catheter material and the catheter's steering performance and evaluates the design optimization of the electromagnetic coils, such as the optimal winding turns for the coils, the optimal size for the side coils and the optimal locations of the coil sets on the catheter. The selected design is validated on a simulated atrial fibrillation ablation in a realistic left atrium model. The simulation verifies that the catheter is successfully able to reach every target on the circumferential lesions.","abstract_html":"This thesis focuses on design, modeling, and analysis of a magnetically actuated robotic intravascular catheter for performing atrial fibrillation ablation under magnetic resonance imaging guidance. Specifically:A three dimensional deflection model of a steerable catheter in free space is proposed and experimentally validated using a hardware prototype. In the proposed method, the catheter is modeled as a series of finite segments. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using the beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter is derived. A Jacobian-based iterative inverse kinematics method for controlling the steerable catheter is presented. The repeatability and accuracy of the open-loop control of the catheter system performing complex geometric trajectories using this inverse kinematics method is experimentally evaluated. The proposed three dimensional kinematic model is extended to incorporate the catheter-surface contact by taking contact forces and torques into account. A systematic approach to the design optimization of a magnetically-actuated steerable catheter for atrial fibrillation ablation in the left atrium, is proposed. The study investigates the relationship between the catheter material and the catheter&#x27;s steering performance and evaluates the design optimization of the electromagnetic coils, such as the optimal winding turns for the coils, the optimal size for the side coils and the optimal locations of the coil sets on the catheter. The selected design is validated on a simulated atrial fibrillation ablation in a realistic left atrium model. The simulation verifies that the catheter is successfully able to reach every target on the circumferential lesions.","abstract_has_math":false,"creators":["Liu, Taoming"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Cavusoglu, Murat"],"committee_members":[],"year":2017,"date_issued":"2017-06-05","date_published":"2017-06-05","updated_at":"2026-11-27T04:41:39Z","subjects":["Robotics","Robots","Robotic Catheter","Magnetically-Actuated Catheter","Atrial Fibrillation Ablation","Real-time MRI Guidance","Robotic Intravascular Catheter","Catheter Deflection Model","Iterative Inverse Kinematics","Catheter-Surface Contact Model","Catheter Design Optimization"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1484654444253783","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1484654444253783","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1484654444253783","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1484654444253783","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cavusoglu, Murat"]},{"key":"dc:creator","label":"Author","values":["Liu, Taoming"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-06-05"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics","Robots","Robotic Catheter","Magnetically-Actuated Catheter","Atrial Fibrillation Ablation","Real-time MRI Guidance","Robotic Intravascular Catheter","Catheter Deflection Model","Iterative Inverse Kinematics","Catheter-Surface Contact Model","Catheter Design Optimization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1484654444253783"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis focuses on design, modeling, and analysis of a magnetically actuated robotic intravascular catheter for performing atrial fibrillation ablation under magnetic resonance imaging guidance. Specifically:A three dimensional deflection model of a steerable catheter in free space is proposed and experimentally validated using a hardware prototype. In the proposed method, the catheter is modeled as a series of finite segments. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using the beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter is derived. A Jacobian-based iterative inverse kinematics method for controlling the steerable catheter is presented. The repeatability and accuracy of the open-loop control of the catheter system performing complex geometric trajectories using this inverse kinematics method is experimentally evaluated. The proposed three dimensional kinematic model is extended to incorporate the catheter-surface contact by taking contact forces and torques into account. A systematic approach to the design optimization of a magnetically-actuated steerable catheter for atrial fibrillation ablation in the left atrium, is proposed. The study investigates the relationship between the catheter material and the catheter's steering performance and evaluates the design optimization of the electromagnetic coils, such as the optimal winding turns for the coils, the optimal size for the side coils and the optimal locations of the coil sets on the catheter. The selected design is validated on a simulated atrial fibrillation ablation in a realistic left atrium model. The simulation verifies that the catheter is successfully able to reach every target on the circumferential lesions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.168","104.13 MB"]},{"key":"dc:title","label":"Title","values":["A MAGNETICALLY-ACTUATED ROBOTIC CATHETER FOR ATRIAL FIBRILLATION ABLATION UNDER REAL-TIME MAGNETIC RESONANCE IMAGING GUIDANCE"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cavusoglu, Murat"],"dc:creator":["Liu, Taoming"],"dc:date":["2017-06-05"],"dc:description":["This thesis focuses on design, modeling, and analysis of a magnetically actuated robotic intravascular catheter for performing atrial fibrillation ablation under magnetic resonance imaging guidance. Specifically:A three dimensional deflection model of a steerable catheter in free space is proposed and experimentally validated using a hardware prototype. In the proposed method, the catheter is modeled as a series of finite segments. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using the beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter is derived. A Jacobian-based iterative inverse kinematics method for controlling the steerable catheter is presented. The repeatability and accuracy of the open-loop control of the catheter system performing complex geometric trajectories using this inverse kinematics method is experimentally evaluated. The proposed three dimensional kinematic model is extended to incorporate the catheter-surface contact by taking contact forces and torques into account. A systematic approach to the design optimization of a magnetically-actuated steerable catheter for atrial fibrillation ablation in the left atrium, is proposed. The study investigates the relationship between the catheter material and the catheter's steering performance and evaluates the design optimization of the electromagnetic coils, such as the optimal winding turns for the coils, the optimal size for the side coils and the optimal locations of the coil sets on the catheter. The selected design is validated on a simulated atrial fibrillation ablation in a realistic left atrium model. The simulation verifies that the catheter is successfully able to reach every target on the circumferential lesions."],"dc:format":["application/pdf","p.168","104.13 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1484654444253783"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Robotics","Robots","Robotic Catheter","Magnetically-Actuated Catheter","Atrial Fibrillation Ablation","Real-time MRI Guidance","Robotic Intravascular Catheter","Catheter Deflection Model","Iterative Inverse Kinematics","Catheter-Surface Contact Model","Catheter Design Optimization"],"dc:title":["A MAGNETICALLY-ACTUATED ROBOTIC CATHETER FOR ATRIAL FIBRILLATION ABLATION UNDER REAL-TIME MAGNETIC RESONANCE IMAGING GUIDANCE"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:41:39Z"}