{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1491600264895472"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1491600264895472","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design and Fabrication of a Highly Flexible Neural Electrode","abstract":"Implanted neural electrodes require high stiffness to ensure the insertion into the target tissue and to provide connections to multichannel contacts. However, recent studies suggest that the stiffness of the implanted device can significantly influenced the tissue response, and subsequently the chronic performance of the electrode. Current methods to improve flexibility methods include adding biodegradable or biomimetic substrate materials. But adding those materials also raise issues such as remaining material following biodegradation or increasing the electrode neural distance. The goal of thesis is to design a flexible electrode whose dimension and flexibility should be similar to that of a single axon, as well as an effective insertion method that can minimize the neural trauma. To achieve the goal, carbon nanotube yarns were chosen for their high flexibility and biocompatibility. The flexible carbon nanotube yarns were combined with a removable stiff needle such as a tungsten needle for the insertion. The diameter () and flexural rigidity of the designed neural interface () are similar to that of a single axon. This neural interface was implanted into the rat sciatic nerve and could record neural activity for long periods of time. This novel device provides the basis for a platform technology for long term recording of neural signals in small nerves such as those of the autonomic nervous system which so far has not been achieved.","abstract_html":"Implanted neural electrodes require high stiffness to ensure the insertion into the target tissue and to provide connections to multichannel contacts. However, recent studies suggest that the stiffness of the implanted device can significantly influenced the tissue response, and subsequently the chronic performance of the electrode. Current methods to improve flexibility methods include adding biodegradable or biomimetic substrate materials. But adding those materials also raise issues such as remaining material following biodegradation or increasing the electrode neural distance. The goal of thesis is to design a flexible electrode whose dimension and flexibility should be similar to that of a single axon, as well as an effective insertion method that can minimize the neural trauma. To achieve the goal, carbon nanotube yarns were chosen for their high flexibility and biocompatibility. The flexible carbon nanotube yarns were combined with a removable stiff needle such as a tungsten needle for the insertion. The diameter () and flexural rigidity of the designed neural interface () are similar to that of a single axon. This neural interface was implanted into the rat sciatic nerve and could record neural activity for long periods of time. This novel device provides the basis for a platform technology for long term recording of neural signals in small nerves such as those of the autonomic nervous system which so far has not been achieved.","abstract_has_math":false,"creators":["Zheng, Yang"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Durand, Dominique"],"committee_members":[],"year":2017,"date_issued":"2017-06-02","date_published":"2017-06-02","updated_at":"2026-11-27T04:47:49Z","subjects":["Biomedical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1491600264895472","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1491600264895472","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1491600264895472","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1491600264895472","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Zheng, Yang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-06-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1491600264895472"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Implanted neural electrodes require high stiffness to ensure the insertion into the target tissue and to provide connections to multichannel contacts. However, recent studies suggest that the stiffness of the implanted device can significantly influenced the tissue response, and subsequently the chronic performance of the electrode. Current methods to improve flexibility methods include adding biodegradable or biomimetic substrate materials. But adding those materials also raise issues such as remaining material following biodegradation or increasing the electrode neural distance. The goal of thesis is to design a flexible electrode whose dimension and flexibility should be similar to that of a single axon, as well as an effective insertion method that can minimize the neural trauma. To achieve the goal, carbon nanotube yarns were chosen for their high flexibility and biocompatibility. The flexible carbon nanotube yarns were combined with a removable stiff needle such as a tungsten needle for the insertion. The diameter () and flexural rigidity of the designed neural interface () are similar to that of a single axon. This neural interface was implanted into the rat sciatic nerve and could record neural activity for long periods of time. This novel device provides the basis for a platform technology for long term recording of neural signals in small nerves such as those of the autonomic nervous system which so far has not been achieved."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.56","11.76 MB"]},{"key":"dc:title","label":"Title","values":["Design and Fabrication of a Highly Flexible Neural Electrode"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Durand, Dominique"],"dc:creator":["Zheng, Yang"],"dc:date":["2017-06-02"],"dc:description":["Implanted neural electrodes require high stiffness to ensure the insertion into the target tissue and to provide connections to multichannel contacts. However, recent studies suggest that the stiffness of the implanted device can significantly influenced the tissue response, and subsequently the chronic performance of the electrode. Current methods to improve flexibility methods include adding biodegradable or biomimetic substrate materials. But adding those materials also raise issues such as remaining material following biodegradation or increasing the electrode neural distance. The goal of thesis is to design a flexible electrode whose dimension and flexibility should be similar to that of a single axon, as well as an effective insertion method that can minimize the neural trauma. To achieve the goal, carbon nanotube yarns were chosen for their high flexibility and biocompatibility. The flexible carbon nanotube yarns were combined with a removable stiff needle such as a tungsten needle for the insertion. The diameter () and flexural rigidity of the designed neural interface () are similar to that of a single axon. This neural interface was implanted into the rat sciatic nerve and could record neural activity for long periods of time. This novel device provides the basis for a platform technology for long term recording of neural signals in small nerves such as those of the autonomic nervous system which so far has not been achieved."],"dc:format":["application/pdf","p.56","11.76 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1491600264895472"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering"],"dc:title":["Design and Fabrication of a Highly Flexible Neural Electrode"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:47:49Z"}