{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1496677783008987"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1496677783008987","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Computer-Assisted Robotic Suturing","abstract":"The design problem addressed in this dissertation is to automate suturing forRobotic Assisted Minimally Invasive Surgery (RAMIS). Automated suturing wouldconsist of intelligent robotic needle-driving, followed by needle extraction, suture-pulling and knot-tying. This process is complicated by considerations of robot jointlimits and reachability, constraints of desirable circular needle-driving and needle-extraction trajectories, unpredictable pose and tangling of slack or ungrasped suture,and concerns of interference between grippers or between a gripper and workspaceconstraints.The work presented here includes: optimal trajectory planning for needle driv-ing (with consideration of joint limits); alternative techniques for knot tying; con-sideration of work-volume minimization; automation of suture pulling; potential forcompliant-motion control in robotic surgery; and design of a graphical user interfacefor supervisory control of suturing.The present work includes experimental evaluation using a pair of industrialrobots, as well as evaluation in simulation using a Gazebo model of a DaVinci surgicalrobot controlled using the Robot Operating System.Results show the ability to exploit robot trajectories and needle grasps that arenon-intuitive and more effective than manual operations by human teleoperators. Thedevelopments in this research offer potential to achieve faster and more dexterous manipulation than is humanly possible.","abstract_html":"The design problem addressed in this dissertation is to automate suturing forRobotic Assisted Minimally Invasive Surgery (RAMIS). Automated suturing wouldconsist of intelligent robotic needle-driving, followed by needle extraction, suture-pulling and knot-tying. This process is complicated by considerations of robot jointlimits and reachability, constraints of desirable circular needle-driving and needle-extraction trajectories, unpredictable pose and tangling of slack or ungrasped suture,and concerns of interference between grippers or between a gripper and workspaceconstraints.The work presented here includes: optimal trajectory planning for needle driv-ing (with consideration of joint limits); alternative techniques for knot tying; con-sideration of work-volume minimization; automation of suture pulling; potential forcompliant-motion control in robotic surgery; and design of a graphical user interfacefor supervisory control of suturing.The present work includes experimental evaluation using a pair of industrialrobots, as well as evaluation in simulation using a Gazebo model of a DaVinci surgicalrobot controlled using the Robot Operating System.Results show the ability to exploit robot trajectories and needle grasps that arenon-intuitive and more effective than manual operations by human teleoperators. Thedevelopments in this research offer potential to achieve faster and more dexterous manipulation than is humanly possible.","abstract_has_math":false,"creators":["Chow, Der-Lin"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Newman, Wyatt"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-09-06","date_published":"2017-09-06","updated_at":"2026-11-27T04:48:03Z","subjects":["Robotics","RAMIS, Supervisory Control, Needle-Driving, Suture-Pulling, Knot-Tying"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1496677783008987","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1496677783008987","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1496677783008987","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1496677783008987","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Newman, Wyatt"]},{"key":"dc:creator","label":"Author","values":["Chow, Der-Lin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-09-06"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics","RAMIS, Supervisory Control, Needle-Driving, Suture-Pulling, Knot-Tying"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1496677783008987"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The design problem addressed in this dissertation is to automate suturing forRobotic Assisted Minimally Invasive Surgery (RAMIS). Automated suturing wouldconsist of intelligent robotic needle-driving, followed by needle extraction, suture-pulling and knot-tying. This process is complicated by considerations of robot jointlimits and reachability, constraints of desirable circular needle-driving and needle-extraction trajectories, unpredictable pose and tangling of slack or ungrasped suture,and concerns of interference between grippers or between a gripper and workspaceconstraints.The work presented here includes: optimal trajectory planning for needle driv-ing (with consideration of joint limits); alternative techniques for knot tying; con-sideration of work-volume minimization; automation of suture pulling; potential forcompliant-motion control in robotic surgery; and design of a graphical user interfacefor supervisory control of suturing.The present work includes experimental evaluation using a pair of industrialrobots, as well as evaluation in simulation using a Gazebo model of a DaVinci surgicalrobot controlled using the Robot Operating System.Results show the ability to exploit robot trajectories and needle grasps that arenon-intuitive and more effective than manual operations by human teleoperators. Thedevelopments in this research offer potential to achieve faster and more dexterous manipulation than is humanly possible."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.138","15.22 MB"]},{"key":"dc:title","label":"Title","values":["Computer-Assisted Robotic Suturing"]}]}],"canonical_facts":{"dc:contributor.advisor":["Newman, Wyatt"],"dc:creator":["Chow, Der-Lin"],"dc:date":["2017-09-06"],"dc:description":["The design problem addressed in this dissertation is to automate suturing forRobotic Assisted Minimally Invasive Surgery (RAMIS). Automated suturing wouldconsist of intelligent robotic needle-driving, followed by needle extraction, suture-pulling and knot-tying. This process is complicated by considerations of robot jointlimits and reachability, constraints of desirable circular needle-driving and needle-extraction trajectories, unpredictable pose and tangling of slack or ungrasped suture,and concerns of interference between grippers or between a gripper and workspaceconstraints.The work presented here includes: optimal trajectory planning for needle driv-ing (with consideration of joint limits); alternative techniques for knot tying; con-sideration of work-volume minimization; automation of suture pulling; potential forcompliant-motion control in robotic surgery; and design of a graphical user interfacefor supervisory control of suturing.The present work includes experimental evaluation using a pair of industrialrobots, as well as evaluation in simulation using a Gazebo model of a DaVinci surgicalrobot controlled using the Robot Operating System.Results show the ability to exploit robot trajectories and needle grasps that arenon-intuitive and more effective than manual operations by human teleoperators. Thedevelopments in this research offer potential to achieve faster and more dexterous manipulation than is humanly possible."],"dc:format":["application/pdf","p.138","15.22 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1496677783008987"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Robotics","RAMIS, Supervisory Control, Needle-Driving, Suture-Pulling, Knot-Tying"],"dc:title":["Computer-Assisted Robotic Suturing"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:03Z"}