{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1496862043661465"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1496862043661465","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Palladium Voltammetric Microelectrode as pH Sensor in an Micro Electrochemical Cell","abstract":"pH-stat is a pH control system that is used for studying biochemical reactions such as enzyme assays. Electrochemical micro-pH-stat based on the rotating sample system as well as microfabrication techniques have been developed in our laboratory previously, with an unmet need of reliable micro pH electrode. In this work we evaluate the Pd electrode using a novel voltammetric pH sensing technique. Pd disk microelectrodes were fabricated and the electrodes showed linear pH reseponse and super-Nerstian sensitivity (~160 mV/pH) at pH 6-7.15 in bulk solution. A micro electrochemical cell combining voltammetric pH sensing and coulometric titration was designed and constructed, together with the analog circuits and control software. The Pd electrodes, however, showed elusive pH response upon further testing in the micro electrochemical cell. In the future a different type of material and/or method may need to be considered for pH sensing in the micro-pH-stat.","abstract_html":"pH-stat is a pH control system that is used for studying biochemical reactions such as enzyme assays. Electrochemical micro-pH-stat based on the rotating sample system as well as microfabrication techniques have been developed in our laboratory previously, with an unmet need of reliable micro pH electrode. In this work we evaluate the Pd electrode using a novel voltammetric pH sensing technique. Pd disk microelectrodes were fabricated and the electrodes showed linear pH reseponse and super-Nerstian sensitivity (~160 mV/pH) at pH 6-7.15 in bulk solution. A micro electrochemical cell combining voltammetric pH sensing and coulometric titration was designed and constructed, together with the analog circuits and control software. The Pd electrodes, however, showed elusive pH response upon further testing in the micro electrochemical cell. In the future a different type of material and/or method may need to be considered for pH sensing in the micro-pH-stat.","abstract_has_math":false,"creators":["Zhang, Zhehao"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gratzl, Miklos"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-08-30","date_published":"2017-08-30","updated_at":"2026-11-27T04:48:03Z","subjects":["Biomedical Engineering","pH-stat","palladium electrode","voltammetry"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1496862043661465","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1496862043661465","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1496862043661465","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1496862043661465","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gratzl, Miklos"]},{"key":"dc:creator","label":"Author","values":["Zhang, Zhehao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-08-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","pH-stat","palladium electrode","voltammetry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1496862043661465"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["pH-stat is a pH control system that is used for studying biochemical reactions such as enzyme assays. Electrochemical micro-pH-stat based on the rotating sample system as well as microfabrication techniques have been developed in our laboratory previously, with an unmet need of reliable micro pH electrode. In this work we evaluate the Pd electrode using a novel voltammetric pH sensing technique. Pd disk microelectrodes were fabricated and the electrodes showed linear pH reseponse and super-Nerstian sensitivity (~160 mV/pH) at pH 6-7.15 in bulk solution. A micro electrochemical cell combining voltammetric pH sensing and coulometric titration was designed and constructed, together with the analog circuits and control software. The Pd electrodes, however, showed elusive pH response upon further testing in the micro electrochemical cell. In the future a different type of material and/or method may need to be considered for pH sensing in the micro-pH-stat."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","3.29 MB"]},{"key":"dc:title","label":"Title","values":["Palladium Voltammetric Microelectrode as pH Sensor in an Micro Electrochemical Cell"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gratzl, Miklos"],"dc:creator":["Zhang, Zhehao"],"dc:date":["2017-08-30"],"dc:description":["pH-stat is a pH control system that is used for studying biochemical reactions such as enzyme assays. Electrochemical micro-pH-stat based on the rotating sample system as well as microfabrication techniques have been developed in our laboratory previously, with an unmet need of reliable micro pH electrode. In this work we evaluate the Pd electrode using a novel voltammetric pH sensing technique. Pd disk microelectrodes were fabricated and the electrodes showed linear pH reseponse and super-Nerstian sensitivity (~160 mV/pH) at pH 6-7.15 in bulk solution. A micro electrochemical cell combining voltammetric pH sensing and coulometric titration was designed and constructed, together with the analog circuits and control software. The Pd electrodes, however, showed elusive pH response upon further testing in the micro electrochemical cell. In the future a different type of material and/or method may need to be considered for pH sensing in the micro-pH-stat."],"dc:format":["application/pdf","3.29 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1496862043661465"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","pH-stat","palladium electrode","voltammetry"],"dc:title":["Palladium Voltammetric Microelectrode as pH Sensor in an Micro Electrochemical Cell"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:03Z"}