{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case150210797013624"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case150210797013624","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DEVELOPMENT OF DYNAMIC PHOSPHORUS-31 AND OXYGEN-17 MAGNETIC RESONANCE SPECTROSCOPY AND IMAGING TECNIQUES FOR PRECLINICAL ASSESSMENT OF ENERGY METABOLISM IN VIVO","abstract":"Adenosine triphosphate (ATP) is the energy currency that maintains physiological activities of the cell. The major source of ATP in aerobic organisms is oxidative phosphorylation occurred in mitochondria. Disruptions of oxidative phosphorylation are associated with various metabolic diseases. Hetero-nuclei MRI plays an important role in assessing functional cell processes such as oxidative metabolism. Specifically, phosphorous-31 (31P) and oxygen-17 (17O) MRS/MRI provide a non-invasive tool to probe mitochondrial oxidative capacity and oxygen consumption, respectively. However, hetero-nuclei MRI in general is challenging due to the low in vivo concentrations and low MR sensitivity. Long acquisition time is usually required even with low spatial resolution. In this thesis, novel approaches for imaging 31P and 17O with high spatial resolution and temporal resolution were developed and demonstrated in small animals at high fields. In particular, this thesis focused on fast 31P MR Spectroscopic Imaging (MRSI) and 17O MRI approaches with non-Cartesian encoding schemes that assess mitochondrial function in skeletal muscle and cerebral oxygen metabolism/water movement across the blood-brain barrier (BBB), respectively.15Four projects are described in this thesis. First, an ischemia-reperfusion protocol was established to evaluate mitochondrial oxidative capacity in type 2 diabetic rats using 31P MRS. Second, a fast dynamic 31P MRSI method using a low-rank model was developed and demonstrated in rat skeletal muscle during ischemia-reperfusion. Third, a dynamic 17O MRI method using golden-angle radial acquisition combined with k-space weighted image contrast (KWIC) reconstruction was developed and validated in simulation studies and phantom experiments. Finally, the 17O MRI method was demonstrated in a mouse model with glioblastoma (GBM) to assess the water movement across BBB after a bolus in injection of 17O-labeled water. The 17O MRI approach was also applied to a mouse model of middle cerebral artery occlusion (MCAO) in 17O-labeled gas inhalation experiments to assess cerebral oxygen metabolism in vivo. The success of these studies will pave the way for fast metabolic imaging using 31P and 17O MRI techniques and allow for the assessment of metabolic alterations in various disease models, such as diabetes, ischemic stroke, etc.","abstract_html":"Adenosine triphosphate (ATP) is the energy currency that maintains physiological activities of the cell. The major source of ATP in aerobic organisms is oxidative phosphorylation occurred in mitochondria. Disruptions of oxidative phosphorylation are associated with various metabolic diseases. Hetero-nuclei MRI plays an important role in assessing functional cell processes such as oxidative metabolism. Specifically, phosphorous-31 (31P) and oxygen-17 (17O) MRS/MRI provide a non-invasive tool to probe mitochondrial oxidative capacity and oxygen consumption, respectively. However, hetero-nuclei MRI in general is challenging due to the low in vivo concentrations and low MR sensitivity. Long acquisition time is usually required even with low spatial resolution. In this thesis, novel approaches for imaging 31P and 17O with high spatial resolution and temporal resolution were developed and demonstrated in small animals at high fields. In particular, this thesis focused on fast 31P MR Spectroscopic Imaging (MRSI) and 17O MRI approaches with non-Cartesian encoding schemes that assess mitochondrial function in skeletal muscle and cerebral oxygen metabolism/water movement across the blood-brain barrier (BBB), respectively.15Four projects are described in this thesis. First, an ischemia-reperfusion protocol was established to evaluate mitochondrial oxidative capacity in type 2 diabetic rats using 31P MRS. Second, a fast dynamic 31P MRSI method using a low-rank model was developed and demonstrated in rat skeletal muscle during ischemia-reperfusion. Third, a dynamic 17O MRI method using golden-angle radial acquisition combined with k-space weighted image contrast (KWIC) reconstruction was developed and validated in simulation studies and phantom experiments. Finally, the 17O MRI method was demonstrated in a mouse model with glioblastoma (GBM) to assess the water movement across BBB after a bolus in injection of 17O-labeled water. The 17O MRI approach was also applied to a mouse model of middle cerebral artery occlusion (MCAO) in 17O-labeled gas inhalation experiments to assess cerebral oxygen metabolism in vivo. The success of these studies will pave the way for fast metabolic imaging using 31P and 17O MRI techniques and allow for the assessment of metabolic alterations in various disease models, such as diabetes, ischemic stroke, etc.","abstract_has_math":false,"creators":["Liu, Yuchi"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Yu, Xin"],"committee_chairs":["Seiberlich, Nicole"],"committee_members":[],"year":2018,"date_issued":"2018-02-02","date_published":"2018-02-02","updated_at":"2026-11-27T04:48:11Z","subjects":["Biomedical Engineering","magnetic resonance imaging, magnetic resonance spectroscopy, energy metabolism, phosphorus-31, oxygen-17"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case150210797013624","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case150210797013624","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase150210797013624","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase150210797013624","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yu, Xin"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Seiberlich, Nicole"]},{"key":"dc:creator","label":"Author","values":["Liu, Yuchi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-02-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","magnetic resonance imaging, magnetic resonance spectroscopy, energy metabolism, phosphorus-31, oxygen-17"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case150210797013624"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Adenosine triphosphate (ATP) is the energy currency that maintains physiological activities of the cell. The major source of ATP in aerobic organisms is oxidative phosphorylation occurred in mitochondria. Disruptions of oxidative phosphorylation are associated with various metabolic diseases. Hetero-nuclei MRI plays an important role in assessing functional cell processes such as oxidative metabolism. Specifically, phosphorous-31 (31P) and oxygen-17 (17O) MRS/MRI provide a non-invasive tool to probe mitochondrial oxidative capacity and oxygen consumption, respectively. However, hetero-nuclei MRI in general is challenging due to the low in vivo concentrations and low MR sensitivity. Long acquisition time is usually required even with low spatial resolution. In this thesis, novel approaches for imaging 31P and 17O with high spatial resolution and temporal resolution were developed and demonstrated in small animals at high fields. In particular, this thesis focused on fast 31P MR Spectroscopic Imaging (MRSI) and 17O MRI approaches with non-Cartesian encoding schemes that assess mitochondrial function in skeletal muscle and cerebral oxygen metabolism/water movement across the blood-brain barrier (BBB), respectively.15Four projects are described in this thesis. First, an ischemia-reperfusion protocol was established to evaluate mitochondrial oxidative capacity in type 2 diabetic rats using 31P MRS. Second, a fast dynamic 31P MRSI method using a low-rank model was developed and demonstrated in rat skeletal muscle during ischemia-reperfusion. Third, a dynamic 17O MRI method using golden-angle radial acquisition combined with k-space weighted image contrast (KWIC) reconstruction was developed and validated in simulation studies and phantom experiments. Finally, the 17O MRI method was demonstrated in a mouse model with glioblastoma (GBM) to assess the water movement across BBB after a bolus in injection of 17O-labeled water. The 17O MRI approach was also applied to a mouse model of middle cerebral artery occlusion (MCAO) in 17O-labeled gas inhalation experiments to assess cerebral oxygen metabolism in vivo. The success of these studies will pave the way for fast metabolic imaging using 31P and 17O MRI techniques and allow for the assessment of metabolic alterations in various disease models, such as diabetes, ischemic stroke, etc."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.154","2.45 MB"]},{"key":"dc:title","label":"Title","values":["DEVELOPMENT OF DYNAMIC PHOSPHORUS-31 AND OXYGEN-17 MAGNETIC RESONANCE SPECTROSCOPY AND IMAGING TECNIQUES FOR PRECLINICAL ASSESSMENT OF ENERGY METABOLISM IN VIVO"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yu, Xin"],"dc:contributor.committeechair":["Seiberlich, Nicole"],"dc:creator":["Liu, Yuchi"],"dc:date":["2018-02-02"],"dc:description":["Adenosine triphosphate (ATP) is the energy currency that maintains physiological activities of the cell. The major source of ATP in aerobic organisms is oxidative phosphorylation occurred in mitochondria. Disruptions of oxidative phosphorylation are associated with various metabolic diseases. Hetero-nuclei MRI plays an important role in assessing functional cell processes such as oxidative metabolism. Specifically, phosphorous-31 (31P) and oxygen-17 (17O) MRS/MRI provide a non-invasive tool to probe mitochondrial oxidative capacity and oxygen consumption, respectively. However, hetero-nuclei MRI in general is challenging due to the low in vivo concentrations and low MR sensitivity. Long acquisition time is usually required even with low spatial resolution. In this thesis, novel approaches for imaging 31P and 17O with high spatial resolution and temporal resolution were developed and demonstrated in small animals at high fields. In particular, this thesis focused on fast 31P MR Spectroscopic Imaging (MRSI) and 17O MRI approaches with non-Cartesian encoding schemes that assess mitochondrial function in skeletal muscle and cerebral oxygen metabolism/water movement across the blood-brain barrier (BBB), respectively.15Four projects are described in this thesis. First, an ischemia-reperfusion protocol was established to evaluate mitochondrial oxidative capacity in type 2 diabetic rats using 31P MRS. Second, a fast dynamic 31P MRSI method using a low-rank model was developed and demonstrated in rat skeletal muscle during ischemia-reperfusion. Third, a dynamic 17O MRI method using golden-angle radial acquisition combined with k-space weighted image contrast (KWIC) reconstruction was developed and validated in simulation studies and phantom experiments. Finally, the 17O MRI method was demonstrated in a mouse model with glioblastoma (GBM) to assess the water movement across BBB after a bolus in injection of 17O-labeled water. The 17O MRI approach was also applied to a mouse model of middle cerebral artery occlusion (MCAO) in 17O-labeled gas inhalation experiments to assess cerebral oxygen metabolism in vivo. The success of these studies will pave the way for fast metabolic imaging using 31P and 17O MRI techniques and allow for the assessment of metabolic alterations in various disease models, such as diabetes, ischemic stroke, etc."],"dc:format":["application/pdf","p.154","2.45 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case150210797013624"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","magnetic resonance imaging, magnetic resonance spectroscopy, energy metabolism, phosphorus-31, oxygen-17"],"dc:title":["DEVELOPMENT OF DYNAMIC PHOSPHORUS-31 AND OXYGEN-17 MAGNETIC RESONANCE SPECTROSCOPY AND IMAGING TECNIQUES FOR PRECLINICAL ASSESSMENT OF ENERGY METABOLISM IN VIVO"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:11Z"}