{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1513081362905414"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1513081362905414","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Automated Polarisation Enhanced Broadband Nuclear Quadrupole Resonance Spectroscopy","abstract":"A permanent magnet with a strong, uniform field is constructed and used to enhance NQR signal by cross-polarisation energy transfer from 1H to 14N. Use of a computer control system allows for robust control of a linear actuator to move samples between the permanent magnet and a probe coil in zero field. A broadband transmitter and receiver is used for arbitrary selection of ¿Q without re-tuning of a matching network between experiments. Results are in good agreement with the literature and show improved NQR signal and high reliability for long term experiments with minimal operator interaction. The applications which are the focus of this work are humanitarian, the goal being to produce useful research pertinent to the identification of counterfeit pharmaceutical drugs and counterfeit supplements, of which many go unnoticed and unknown by the general public. Potential applications and research scope are discussed in the context of experimental results.","abstract_html":"A permanent magnet with a strong, uniform field is constructed and used to enhance NQR signal by cross-polarisation energy transfer from 1H to 14N. Use of a computer control system allows for robust control of a linear actuator to move samples between the permanent magnet and a probe coil in zero field. A broadband transmitter and receiver is used for arbitrary selection of ¿Q without re-tuning of a matching network between experiments. Results are in good agreement with the literature and show improved NQR signal and high reliability for long term experiments with minimal operator interaction. The applications which are the focus of this work are humanitarian, the goal being to produce useful research pertinent to the identification of counterfeit pharmaceutical drugs and counterfeit supplements, of which many go unnoticed and unknown by the general public. Potential applications and research scope are discussed in the context of experimental results.","abstract_has_math":false,"creators":["Glickstein, Jarred S."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mandal, Soumyajit"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-27T04:48:23Z","subjects":["Electrical Engineering","Engineering","Environmental Health","Health Sciences","Mechanical Engineering","Chemistry","Automated","Polarisation","Enhanced","Broadband","Nuclear","Quadrupole","Resonance","Spectroscopy"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1513081362905414","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1513081362905414","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1513081362905414","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1513081362905414","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mandal, Soumyajit"]},{"key":"dc:creator","label":"Author","values":["Glickstein, Jarred S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Engineering","Environmental Health","Health Sciences","Mechanical Engineering","Chemistry","Automated","Polarisation","Enhanced","Broadband","Nuclear","Quadrupole","Resonance","Spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1513081362905414"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A permanent magnet with a strong, uniform field is constructed and used to enhance NQR signal by cross-polarisation energy transfer from 1H to 14N. Use of a computer control system allows for robust control of a linear actuator to move samples between the permanent magnet and a probe coil in zero field. A broadband transmitter and receiver is used for arbitrary selection of ¿Q without re-tuning of a matching network between experiments. Results are in good agreement with the literature and show improved NQR signal and high reliability for long term experiments with minimal operator interaction. The applications which are the focus of this work are humanitarian, the goal being to produce useful research pertinent to the identification of counterfeit pharmaceutical drugs and counterfeit supplements, of which many go unnoticed and unknown by the general public. Potential applications and research scope are discussed in the context of experimental results."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.153","29.59 MB"]},{"key":"dc:title","label":"Title","values":["Automated Polarisation Enhanced Broadband Nuclear Quadrupole Resonance Spectroscopy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mandal, Soumyajit"],"dc:creator":["Glickstein, Jarred S."],"dc:date":["2017"],"dc:description":["A permanent magnet with a strong, uniform field is constructed and used to enhance NQR signal by cross-polarisation energy transfer from 1H to 14N. Use of a computer control system allows for robust control of a linear actuator to move samples between the permanent magnet and a probe coil in zero field. A broadband transmitter and receiver is used for arbitrary selection of ¿Q without re-tuning of a matching network between experiments. Results are in good agreement with the literature and show improved NQR signal and high reliability for long term experiments with minimal operator interaction. The applications which are the focus of this work are humanitarian, the goal being to produce useful research pertinent to the identification of counterfeit pharmaceutical drugs and counterfeit supplements, of which many go unnoticed and unknown by the general public. Potential applications and research scope are discussed in the context of experimental results."],"dc:format":["application/pdf","p.153","29.59 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1513081362905414"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Engineering","Environmental Health","Health Sciences","Mechanical Engineering","Chemistry","Automated","Polarisation","Enhanced","Broadband","Nuclear","Quadrupole","Resonance","Spectroscopy"],"dc:title":["Automated Polarisation Enhanced Broadband Nuclear Quadrupole Resonance Spectroscopy"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:23Z"}