{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case151385068164148"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case151385068164148","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"MULTISCALE MULTIPHYSICS THERMO-MECHANICAL MODELING OF AN MGB<sub>2</sub> BASED CONDUCTION COOLED MRI MAGNET SYSTEM","abstract":"The past decade has experienced a surge in the price of liquid helium (LHe) affecting the cryogenic industry severely. As MRI machines are the most abundant consumer of LHe, disruption in the market growth is unavoidable if alternative technologies are unavailable. Replacement of current low-temperature superconductors such as Niobium-Titanium (NbTi) and Niobium-Tin (Nb3Sn) with an affordable high-temperature superconductor such as Magnesium diboride (MgB<sub>2</sub>) is a promising solution. However, strain sensitivity of the recently discovered superconductor MgB<sub>2</sub> places a strict design limit on an MRI magnet. Since the manufacturing of the MRI magnet costs millions of dollars, a computational model is sought to analyze the feasibility of the novel conduction cooled MgB<sub>2</sub> based full body MRI magnet. MRI magnet bundles (solenoids) consist of commercial grade superconductors which are a composite metal matrix. Thus computational modeling of MRI magnet systems spans across multiple scales and different physics fields. In this work, a complete multiphysics-multiscale approach to analyzing the feasibility of a next-generation conduction-cooled MRI magnet has demonstrated acceptable strain (<0.2%) and stress (<100 MPa) development, suggesting the practicality of such system. A complete non-linear finite element analysis (FEA) model for 1.5 T full body MRI magnet has been developed using ANSYS, and a prototype magnet bundle is under investigation for experimental tests at Ohio State University’s `Center for Superconducting and Magnetic Materials.' The experimental results are promising and assure this novel technology as a replacement to the current LHe cooled MRI magnets.","abstract_html":"The past decade has experienced a surge in the price of liquid helium (LHe) affecting the cryogenic industry severely. As MRI machines are the most abundant consumer of LHe, disruption in the market growth is unavoidable if alternative technologies are unavailable. Replacement of current low-temperature superconductors such as Niobium-Titanium (NbTi) and Niobium-Tin (Nb3Sn) with an affordable high-temperature superconductor such as Magnesium diboride (MgB&lt;sub&gt;2&lt;/sub&gt;) is a promising solution. However, strain sensitivity of the recently discovered superconductor MgB&lt;sub&gt;2&lt;/sub&gt; places a strict design limit on an MRI magnet. Since the manufacturing of the MRI magnet costs millions of dollars, a computational model is sought to analyze the feasibility of the novel conduction cooled MgB&lt;sub&gt;2&lt;/sub&gt; based full body MRI magnet. MRI magnet bundles (solenoids) consist of commercial grade superconductors which are a composite metal matrix. Thus computational modeling of MRI magnet systems spans across multiple scales and different physics fields. In this work, a complete multiphysics-multiscale approach to analyzing the feasibility of a next-generation conduction-cooled MRI magnet has demonstrated acceptable strain (&lt;0.2%) and stress (&lt;100 MPa) development, suggesting the practicality of such system. A complete non-linear finite element analysis (FEA) model for 1.5 T full body MRI magnet has been developed using ANSYS, and a prototype magnet bundle is under investigation for experimental tests at Ohio State University’s `Center for Superconducting and Magnetic Materials.&#x27; The experimental results are promising and assure this novel technology as a replacement to the current LHe cooled MRI magnets.","abstract_has_math":false,"creators":["Amin, Abdullah Al"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Martens, Michael","Akkus, Ozan"],"committee_members":[],"year":2018,"date_issued":"2018-02-01","date_published":"2018-02-01","updated_at":"2026-11-27T04:48:23Z","subjects":["Mechanical Engineering","Physics","MgB2","Magnetic Resonance Imaging","MRI","Stress Strain of MRI","Multiscale modeling, Multiphysics, Strain modeling of MRI, MRI Magnet Quench, Superconducting Magnet, Metal Matrix Composite, Superconducting wire, Conduction Cooled MRI"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case151385068164148","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case151385068164148","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase151385068164148","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase151385068164148","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Martens, Michael","Akkus, Ozan"]},{"key":"dc:creator","label":"Author","values":["Amin, Abdullah Al"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-02-01"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Physics","MgB2","Magnetic Resonance Imaging","MRI","Stress Strain of MRI","Multiscale modeling, Multiphysics, Strain modeling of MRI, MRI Magnet Quench, Superconducting Magnet, Metal Matrix Composite, Superconducting wire, Conduction Cooled MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case151385068164148"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The past decade has experienced a surge in the price of liquid helium (LHe) affecting the cryogenic industry severely. As MRI machines are the most abundant consumer of LHe, disruption in the market growth is unavoidable if alternative technologies are unavailable. Replacement of current low-temperature superconductors such as Niobium-Titanium (NbTi) and Niobium-Tin (Nb3Sn) with an affordable high-temperature superconductor such as Magnesium diboride (MgB<sub>2</sub>) is a promising solution. However, strain sensitivity of the recently discovered superconductor MgB<sub>2</sub> places a strict design limit on an MRI magnet. Since the manufacturing of the MRI magnet costs millions of dollars, a computational model is sought to analyze the feasibility of the novel conduction cooled MgB<sub>2</sub> based full body MRI magnet. MRI magnet bundles (solenoids) consist of commercial grade superconductors which are a composite metal matrix. Thus computational modeling of MRI magnet systems spans across multiple scales and different physics fields. In this work, a complete multiphysics-multiscale approach to analyzing the feasibility of a next-generation conduction-cooled MRI magnet has demonstrated acceptable strain (<0.2%) and stress (<100 MPa) development, suggesting the practicality of such system. A complete non-linear finite element analysis (FEA) model for 1.5 T full body MRI magnet has been developed using ANSYS, and a prototype magnet bundle is under investigation for experimental tests at Ohio State University’s `Center for Superconducting and Magnetic Materials.' The experimental results are promising and assure this novel technology as a replacement to the current LHe cooled MRI magnets."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.271","5.57 MB"]},{"key":"dc:title","label":"Title","values":["MULTISCALE MULTIPHYSICS THERMO-MECHANICAL MODELING OF AN MGB<sub>2</sub> BASED CONDUCTION COOLED MRI MAGNET SYSTEM"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Martens, Michael","Akkus, Ozan"],"dc:creator":["Amin, Abdullah Al"],"dc:date":["2018-02-01"],"dc:description":["The past decade has experienced a surge in the price of liquid helium (LHe) affecting the cryogenic industry severely. As MRI machines are the most abundant consumer of LHe, disruption in the market growth is unavoidable if alternative technologies are unavailable. Replacement of current low-temperature superconductors such as Niobium-Titanium (NbTi) and Niobium-Tin (Nb3Sn) with an affordable high-temperature superconductor such as Magnesium diboride (MgB<sub>2</sub>) is a promising solution. However, strain sensitivity of the recently discovered superconductor MgB<sub>2</sub> places a strict design limit on an MRI magnet. Since the manufacturing of the MRI magnet costs millions of dollars, a computational model is sought to analyze the feasibility of the novel conduction cooled MgB<sub>2</sub> based full body MRI magnet. MRI magnet bundles (solenoids) consist of commercial grade superconductors which are a composite metal matrix. Thus computational modeling of MRI magnet systems spans across multiple scales and different physics fields. In this work, a complete multiphysics-multiscale approach to analyzing the feasibility of a next-generation conduction-cooled MRI magnet has demonstrated acceptable strain (<0.2%) and stress (<100 MPa) development, suggesting the practicality of such system. A complete non-linear finite element analysis (FEA) model for 1.5 T full body MRI magnet has been developed using ANSYS, and a prototype magnet bundle is under investigation for experimental tests at Ohio State University’s `Center for Superconducting and Magnetic Materials.' The experimental results are promising and assure this novel technology as a replacement to the current LHe cooled MRI magnets."],"dc:format":["application/pdf","p.271","5.57 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case151385068164148"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Physics","MgB2","Magnetic Resonance Imaging","MRI","Stress Strain of MRI","Multiscale modeling, Multiphysics, Strain modeling of MRI, MRI Magnet Quench, Superconducting Magnet, Metal Matrix Composite, Superconducting wire, Conduction Cooled MRI"],"dc:title":["MULTISCALE MULTIPHYSICS THERMO-MECHANICAL MODELING OF AN MGB<sub>2</sub> BASED CONDUCTION COOLED MRI MAGNET SYSTEM"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:23Z"}