{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1522838106560133"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1522838106560133","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Modeling Degradation of Photovoltaic Modules using Machine Learning of Electroluminescent Images","abstract":"Understanding lifetime performance of field deployed photovoltaic (PV) systems is paramount to the long-term success of the PV industry. Of the many characterization methods available for study of modules undergoing indoor accelerated tests as well as outdoor real-world system monitoring, imaging techniques provide a great volume of high resolution information regarding the health of a module. Electroluminescent (EL) imaging captures the spatial variance of bulk recombination resolved at the wafer front-side surface. Intensity distributions reveal features, such as cracking and corrosion, providing insights into the extent of degradation the module has experienced. Using step-wise imagery, the evolution of degradation has been studied and quantified for five brands of damp-heat exposed commercial modules. Using supervised machine learning, three degradation features were classified to greater than 95% accuracy by training a scalable classification pipeline which can now be used by PV researchers for unbiased, repeatable, and time-efficient feature identification in EL images. For busbar darkening specifically, a lifetime performance prediction model was developed for determining degradation of field deployed modules using only images.This method removes the issue of accelerated indoor to real-world time scaling for power performance prediction. Additionally, current-voltage (I-V) module data has been correlated with the numeric intensity distribution from EL images showing strong correlation between series resistance, maximum power, and wafer darkening. A normalized busbar corrosion width was calculated, which was demonstrated to correlate well with I-V electrical properties, while also providing greater insight to the mechanistic behavior governing I-V characteristics. A composite Feature Ratio metric for busbar darkening was developed and applied to 3 brands of modules. The slope of Pmp vs. the Feature Ratio for brands A, B, and D were -6.8, -42.0, and -3.7, respectively, which trended similarly to the degradation rates of Pmp after 3000 hours of damp-heat exposure with values of -6.0%, -30.4% and -2.7%, respectively, clearly identifying brand B as a poor performing module under damp-heat conditions.","abstract_html":"Understanding lifetime performance of field deployed photovoltaic (PV) systems is paramount to the long-term success of the PV industry. Of the many characterization methods available for study of modules undergoing indoor accelerated tests as well as outdoor real-world system monitoring, imaging techniques provide a great volume of high resolution information regarding the health of a module. Electroluminescent (EL) imaging captures the spatial variance of bulk recombination resolved at the wafer front-side surface. Intensity distributions reveal features, such as cracking and corrosion, providing insights into the extent of degradation the module has experienced. Using step-wise imagery, the evolution of degradation has been studied and quantified for five brands of damp-heat exposed commercial modules. Using supervised machine learning, three degradation features were classified to greater than 95% accuracy by training a scalable classification pipeline which can now be used by PV researchers for unbiased, repeatable, and time-efficient feature identification in EL images. For busbar darkening specifically, a lifetime performance prediction model was developed for determining degradation of field deployed modules using only images.This method removes the issue of accelerated indoor to real-world time scaling for power performance prediction. Additionally, current-voltage (I-V) module data has been correlated with the numeric intensity distribution from EL images showing strong correlation between series resistance, maximum power, and wafer darkening. A normalized busbar corrosion width was calculated, which was demonstrated to correlate well with I-V electrical properties, while also providing greater insight to the mechanistic behavior governing I-V characteristics. A composite Feature Ratio metric for busbar darkening was developed and applied to 3 brands of modules. The slope of Pmp vs. the Feature Ratio for brands A, B, and D were -6.8, -42.0, and -3.7, respectively, which trended similarly to the degradation rates of Pmp after 3000 hours of damp-heat exposure with values of -6.0%, -30.4% and -2.7%, respectively, clearly identifying brand B as a poor performing module under damp-heat conditions.","abstract_has_math":false,"creators":["Fada, Justin S., Fada"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["French, Roger"],"committee_chairs":["Abramson, Alexis"],"committee_members":[],"year":2018,"date_issued":"2018-05-31","date_published":"2018-05-31","updated_at":"2026-11-27T04:48:26Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1522838106560133","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1522838106560133","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1522838106560133","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1522838106560133","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["French, Roger"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Abramson, Alexis"]},{"key":"dc:creator","label":"Author","values":["Fada, Justin S., Fada"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-05-31"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1522838106560133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Understanding lifetime performance of field deployed photovoltaic (PV) systems is paramount to the long-term success of the PV industry. Of the many characterization methods available for study of modules undergoing indoor accelerated tests as well as outdoor real-world system monitoring, imaging techniques provide a great volume of high resolution information regarding the health of a module. Electroluminescent (EL) imaging captures the spatial variance of bulk recombination resolved at the wafer front-side surface. Intensity distributions reveal features, such as cracking and corrosion, providing insights into the extent of degradation the module has experienced. Using step-wise imagery, the evolution of degradation has been studied and quantified for five brands of damp-heat exposed commercial modules. Using supervised machine learning, three degradation features were classified to greater than 95% accuracy by training a scalable classification pipeline which can now be used by PV researchers for unbiased, repeatable, and time-efficient feature identification in EL images. For busbar darkening specifically, a lifetime performance prediction model was developed for determining degradation of field deployed modules using only images.This method removes the issue of accelerated indoor to real-world time scaling for power performance prediction. Additionally, current-voltage (I-V) module data has been correlated with the numeric intensity distribution from EL images showing strong correlation between series resistance, maximum power, and wafer darkening. A normalized busbar corrosion width was calculated, which was demonstrated to correlate well with I-V electrical properties, while also providing greater insight to the mechanistic behavior governing I-V characteristics. A composite Feature Ratio metric for busbar darkening was developed and applied to 3 brands of modules. The slope of Pmp vs. the Feature Ratio for brands A, B, and D were -6.8, -42.0, and -3.7, respectively, which trended similarly to the degradation rates of Pmp after 3000 hours of damp-heat exposure with values of -6.0%, -30.4% and -2.7%, respectively, clearly identifying brand B as a poor performing module under damp-heat conditions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.137","27.18 MB"]},{"key":"dc:title","label":"Title","values":["Modeling Degradation of Photovoltaic Modules using Machine Learning of Electroluminescent Images"]}]}],"canonical_facts":{"dc:contributor.advisor":["French, Roger"],"dc:contributor.committeechair":["Abramson, Alexis"],"dc:creator":["Fada, Justin S., Fada"],"dc:date":["2018-05-31"],"dc:description":["Understanding lifetime performance of field deployed photovoltaic (PV) systems is paramount to the long-term success of the PV industry. Of the many characterization methods available for study of modules undergoing indoor accelerated tests as well as outdoor real-world system monitoring, imaging techniques provide a great volume of high resolution information regarding the health of a module. Electroluminescent (EL) imaging captures the spatial variance of bulk recombination resolved at the wafer front-side surface. Intensity distributions reveal features, such as cracking and corrosion, providing insights into the extent of degradation the module has experienced. Using step-wise imagery, the evolution of degradation has been studied and quantified for five brands of damp-heat exposed commercial modules. Using supervised machine learning, three degradation features were classified to greater than 95% accuracy by training a scalable classification pipeline which can now be used by PV researchers for unbiased, repeatable, and time-efficient feature identification in EL images. For busbar darkening specifically, a lifetime performance prediction model was developed for determining degradation of field deployed modules using only images.This method removes the issue of accelerated indoor to real-world time scaling for power performance prediction. Additionally, current-voltage (I-V) module data has been correlated with the numeric intensity distribution from EL images showing strong correlation between series resistance, maximum power, and wafer darkening. A normalized busbar corrosion width was calculated, which was demonstrated to correlate well with I-V electrical properties, while also providing greater insight to the mechanistic behavior governing I-V characteristics. A composite Feature Ratio metric for busbar darkening was developed and applied to 3 brands of modules. The slope of Pmp vs. the Feature Ratio for brands A, B, and D were -6.8, -42.0, and -3.7, respectively, which trended similarly to the degradation rates of Pmp after 3000 hours of damp-heat exposure with values of -6.0%, -30.4% and -2.7%, respectively, clearly identifying brand B as a poor performing module under damp-heat conditions."],"dc:format":["application/pdf","p.137","27.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1522838106560133"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering"],"dc:title":["Modeling Degradation of Photovoltaic Modules using Machine Learning of Electroluminescent Images"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:26Z"}