{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1523017967730333"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1523017967730333","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"QUENCH PROTECTION STUDIES OF MAGNESIUM DIBORIDE SUPERCONDUCTING MAGNETS FOR MRI APPLICATIONS","abstract":"The use of magnesium diboride (MgB<sub>2</sub>) superconducting wires inside a conduction cooled MRI main magnet could reduce the amount of liquid helium (LHe) from 2000 to only a few liters. The quench protection of MgB<sub>2</sub> superconducting magnets remains a primary challenge because the higher enthalpy margin and slower normal zone propagation velocity (NZPV) of MgB<sub>2</sub> wire compared to conventional niobium titanium (NbTi) wire leads to a higher temperature rise, which could damage the magnet, necessitating the use of an active protection system. Both 0.5 T and 1.5 T whole-body conduction cooled MRI main magnet designs with MgB<sub>2</sub> wire have been presented here with dimensions comparable to current scanners. The quench propagation throughout the magnet has been numerically modelled using custom code in MATLAB, and the procedure consists of the interaction between thermal, magnetic, and circuit models. The governing heat equations were solved using the implicit Douglas-Gunn and Peaceman-Rachford methods, and the governing circuit equations were solved using Heun’s method. From these simulations, it was found that the temperature rise inside a quenched MRI coil could be reduced at the time of quench detection by increasing the thermal and/or electrical conductivity of the wire composite. A quench protection system using Coupling Loss Induced Quench (CLIQ) has been investigated for the two magnet designs where an external charged capacitor introduces an oscillating current into the coils, which generates heat inside the coils due to inter-filament coupling currents. The coil’s increased resistance reduces the current, leading to a lower hot-spot temperature. Various parameters were varied including the wire’s twist, number of CLIQ units, and the voltage and capacitance of each unit to determine their effect on the magnet’s protection. Finally, these quench simulations were performed on a single MgB<sub>2</sub> test coil to determine the quench propagation inside the coil and the effect of a dump resistor and/or external protection heater on the protection of the coil. Therefore, this work has numerically investigated the quench propagation of MgB<sub>2</sub> MRI coils and demonstrated both ways to reduce the hot-spot temperature and a potential method of quench protection.","abstract_html":"The use of magnesium diboride (MgB&lt;sub&gt;2&lt;/sub&gt;) superconducting wires inside a conduction cooled MRI main magnet could reduce the amount of liquid helium (LHe) from 2000 to only a few liters. The quench protection of MgB&lt;sub&gt;2&lt;/sub&gt; superconducting magnets remains a primary challenge because the higher enthalpy margin and slower normal zone propagation velocity (NZPV) of MgB&lt;sub&gt;2&lt;/sub&gt; wire compared to conventional niobium titanium (NbTi) wire leads to a higher temperature rise, which could damage the magnet, necessitating the use of an active protection system. Both 0.5 T and 1.5 T whole-body conduction cooled MRI main magnet designs with MgB&lt;sub&gt;2&lt;/sub&gt; wire have been presented here with dimensions comparable to current scanners. The quench propagation throughout the magnet has been numerically modelled using custom code in MATLAB, and the procedure consists of the interaction between thermal, magnetic, and circuit models. The governing heat equations were solved using the implicit Douglas-Gunn and Peaceman-Rachford methods, and the governing circuit equations were solved using Heun’s method. From these simulations, it was found that the temperature rise inside a quenched MRI coil could be reduced at the time of quench detection by increasing the thermal and/or electrical conductivity of the wire composite. A quench protection system using Coupling Loss Induced Quench (CLIQ) has been investigated for the two magnet designs where an external charged capacitor introduces an oscillating current into the coils, which generates heat inside the coils due to inter-filament coupling currents. The coil’s increased resistance reduces the current, leading to a lower hot-spot temperature. Various parameters were varied including the wire’s twist, number of CLIQ units, and the voltage and capacitance of each unit to determine their effect on the magnet’s protection. Finally, these quench simulations were performed on a single MgB&lt;sub&gt;2&lt;/sub&gt; test coil to determine the quench propagation inside the coil and the effect of a dump resistor and/or external protection heater on the protection of the coil. Therefore, this work has numerically investigated the quench propagation of MgB&lt;sub&gt;2&lt;/sub&gt; MRI coils and demonstrated both ways to reduce the hot-spot temperature and a potential method of quench protection.","abstract_has_math":false,"creators":["Poole, Charles Randall"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Martens, Michael"],"committee_members":[],"year":2018,"date_issued":"2018-06-01","date_published":"2018-06-01","updated_at":"2026-11-27T04:48:26Z","subjects":["Physics","Electromagnetics","Magnetic Resonance Imaging","MRI","Magnesium Diboride","MgB2","High Temperature Superconductor","Quench Protection","Multiphysics Modelling","Numeric Simulation","Superconducting Magnet","Computational Physics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1523017967730333","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1523017967730333","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1523017967730333","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1523017967730333","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Martens, Michael"]},{"key":"dc:creator","label":"Author","values":["Poole, Charles Randall"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-06-01"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Electromagnetics","Magnetic Resonance Imaging","MRI","Magnesium Diboride","MgB2","High Temperature Superconductor","Quench Protection","Multiphysics Modelling","Numeric Simulation","Superconducting Magnet","Computational Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1523017967730333"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The use of magnesium diboride (MgB<sub>2</sub>) superconducting wires inside a conduction cooled MRI main magnet could reduce the amount of liquid helium (LHe) from 2000 to only a few liters. The quench protection of MgB<sub>2</sub> superconducting magnets remains a primary challenge because the higher enthalpy margin and slower normal zone propagation velocity (NZPV) of MgB<sub>2</sub> wire compared to conventional niobium titanium (NbTi) wire leads to a higher temperature rise, which could damage the magnet, necessitating the use of an active protection system. Both 0.5 T and 1.5 T whole-body conduction cooled MRI main magnet designs with MgB<sub>2</sub> wire have been presented here with dimensions comparable to current scanners. The quench propagation throughout the magnet has been numerically modelled using custom code in MATLAB, and the procedure consists of the interaction between thermal, magnetic, and circuit models. The governing heat equations were solved using the implicit Douglas-Gunn and Peaceman-Rachford methods, and the governing circuit equations were solved using Heun’s method. From these simulations, it was found that the temperature rise inside a quenched MRI coil could be reduced at the time of quench detection by increasing the thermal and/or electrical conductivity of the wire composite. A quench protection system using Coupling Loss Induced Quench (CLIQ) has been investigated for the two magnet designs where an external charged capacitor introduces an oscillating current into the coils, which generates heat inside the coils due to inter-filament coupling currents. The coil’s increased resistance reduces the current, leading to a lower hot-spot temperature. Various parameters were varied including the wire’s twist, number of CLIQ units, and the voltage and capacitance of each unit to determine their effect on the magnet’s protection. Finally, these quench simulations were performed on a single MgB<sub>2</sub> test coil to determine the quench propagation inside the coil and the effect of a dump resistor and/or external protection heater on the protection of the coil. Therefore, this work has numerically investigated the quench propagation of MgB<sub>2</sub> MRI coils and demonstrated both ways to reduce the hot-spot temperature and a potential method of quench protection."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.212","2.18 MB"]},{"key":"dc:title","label":"Title","values":["QUENCH PROTECTION STUDIES OF MAGNESIUM DIBORIDE SUPERCONDUCTING MAGNETS FOR MRI APPLICATIONS"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Martens, Michael"],"dc:creator":["Poole, Charles Randall"],"dc:date":["2018-06-01"],"dc:description":["The use of magnesium diboride (MgB<sub>2</sub>) superconducting wires inside a conduction cooled MRI main magnet could reduce the amount of liquid helium (LHe) from 2000 to only a few liters. The quench protection of MgB<sub>2</sub> superconducting magnets remains a primary challenge because the higher enthalpy margin and slower normal zone propagation velocity (NZPV) of MgB<sub>2</sub> wire compared to conventional niobium titanium (NbTi) wire leads to a higher temperature rise, which could damage the magnet, necessitating the use of an active protection system. Both 0.5 T and 1.5 T whole-body conduction cooled MRI main magnet designs with MgB<sub>2</sub> wire have been presented here with dimensions comparable to current scanners. The quench propagation throughout the magnet has been numerically modelled using custom code in MATLAB, and the procedure consists of the interaction between thermal, magnetic, and circuit models. The governing heat equations were solved using the implicit Douglas-Gunn and Peaceman-Rachford methods, and the governing circuit equations were solved using Heun’s method. From these simulations, it was found that the temperature rise inside a quenched MRI coil could be reduced at the time of quench detection by increasing the thermal and/or electrical conductivity of the wire composite. A quench protection system using Coupling Loss Induced Quench (CLIQ) has been investigated for the two magnet designs where an external charged capacitor introduces an oscillating current into the coils, which generates heat inside the coils due to inter-filament coupling currents. The coil’s increased resistance reduces the current, leading to a lower hot-spot temperature. Various parameters were varied including the wire’s twist, number of CLIQ units, and the voltage and capacitance of each unit to determine their effect on the magnet’s protection. Finally, these quench simulations were performed on a single MgB<sub>2</sub> test coil to determine the quench propagation inside the coil and the effect of a dump resistor and/or external protection heater on the protection of the coil. Therefore, this work has numerically investigated the quench propagation of MgB<sub>2</sub> MRI coils and demonstrated both ways to reduce the hot-spot temperature and a potential method of quench protection."],"dc:format":["application/pdf","p.212","2.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1523017967730333"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Electromagnetics","Magnetic Resonance Imaging","MRI","Magnesium Diboride","MgB2","High Temperature Superconductor","Quench Protection","Multiphysics Modelling","Numeric Simulation","Superconducting Magnet","Computational Physics"],"dc:title":["QUENCH PROTECTION STUDIES OF MAGNESIUM DIBORIDE SUPERCONDUCTING MAGNETS FOR MRI APPLICATIONS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:26Z"}