{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case153079448199171"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case153079448199171","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Miniature Wireless Neural Recording and Stimulating System for Chronic Implantation in Freely Moving Animals","abstract":"Bioelectronic Medicine Therapies offer a promising alternative to traditional procedures, and implantable devices are crucial for its development. This thesis presents a miniature, low power, 2 channel integrated wireless neural recording and stimulating system with sampling rates of 20ksps to allow researchers to understand the organ functions and develop therapies in freely moving small animals. The wireless implant uses Carbon Nano Tube Yarn (CNTY) electrodes to interface with the peripheral nerves and record signals. High data transmission rates are achieved by using an Ultra-wideband Impulse Radio (UWB-IR) transmitter and wireless switching control is provided by Bluetooth Low Energy (BLE). The UWB transmitter is primarily designed to make it implantable in freely moving rats for long periods of time, to chronically record neural activity in the peripheral nerves and stimulate them wirelessly. Preliminary experiments and bench test results have confirmed its functioning with high data transmission rate and low power consumption.","abstract_html":"Bioelectronic Medicine Therapies offer a promising alternative to traditional procedures, and implantable devices are crucial for its development. This thesis presents a miniature, low power, 2 channel integrated wireless neural recording and stimulating system with sampling rates of 20ksps to allow researchers to understand the organ functions and develop therapies in freely moving small animals. The wireless implant uses Carbon Nano Tube Yarn (CNTY) electrodes to interface with the peripheral nerves and record signals. High data transmission rates are achieved by using an Ultra-wideband Impulse Radio (UWB-IR) transmitter and wireless switching control is provided by Bluetooth Low Energy (BLE). The UWB transmitter is primarily designed to make it implantable in freely moving rats for long periods of time, to chronically record neural activity in the peripheral nerves and stimulate them wirelessly. Preliminary experiments and bench test results have confirmed its functioning with high data transmission rate and low power consumption.","abstract_has_math":false,"creators":["Kanchwala, Mustafa Ashiq Hussain"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Durand, Dominique"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-27T04:48:39Z","subjects":["Biomedical Engineering","Biomedical Research","Neurosciences","Bioelectronic Medicine, Wireless, Ultra-wideband, Implantable device, Telemetry, Neural recording, Peripheral nerve, Vagus nerve"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case153079448199171","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case153079448199171","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase153079448199171","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase153079448199171","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Kanchwala, Mustafa Ashiq Hussain"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Neurosciences","Bioelectronic Medicine, Wireless, Ultra-wideband, Implantable device, Telemetry, Neural recording, Peripheral nerve, Vagus nerve"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case153079448199171"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Bioelectronic Medicine Therapies offer a promising alternative to traditional procedures, and implantable devices are crucial for its development. This thesis presents a miniature, low power, 2 channel integrated wireless neural recording and stimulating system with sampling rates of 20ksps to allow researchers to understand the organ functions and develop therapies in freely moving small animals. The wireless implant uses Carbon Nano Tube Yarn (CNTY) electrodes to interface with the peripheral nerves and record signals. High data transmission rates are achieved by using an Ultra-wideband Impulse Radio (UWB-IR) transmitter and wireless switching control is provided by Bluetooth Low Energy (BLE). The UWB transmitter is primarily designed to make it implantable in freely moving rats for long periods of time, to chronically record neural activity in the peripheral nerves and stimulate them wirelessly. Preliminary experiments and bench test results have confirmed its functioning with high data transmission rate and low power consumption."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.64","3.01 MB"]},{"key":"dc:title","label":"Title","values":["A Miniature Wireless Neural Recording and Stimulating System for Chronic Implantation in Freely Moving Animals"]}]}],"canonical_facts":{"dc:contributor.advisor":["Durand, Dominique"],"dc:creator":["Kanchwala, Mustafa Ashiq Hussain"],"dc:date":["2018"],"dc:description":["Bioelectronic Medicine Therapies offer a promising alternative to traditional procedures, and implantable devices are crucial for its development. This thesis presents a miniature, low power, 2 channel integrated wireless neural recording and stimulating system with sampling rates of 20ksps to allow researchers to understand the organ functions and develop therapies in freely moving small animals. The wireless implant uses Carbon Nano Tube Yarn (CNTY) electrodes to interface with the peripheral nerves and record signals. High data transmission rates are achieved by using an Ultra-wideband Impulse Radio (UWB-IR) transmitter and wireless switching control is provided by Bluetooth Low Energy (BLE). The UWB transmitter is primarily designed to make it implantable in freely moving rats for long periods of time, to chronically record neural activity in the peripheral nerves and stimulate them wirelessly. Preliminary experiments and bench test results have confirmed its functioning with high data transmission rate and low power consumption."],"dc:format":["application/pdf","p.64","3.01 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case153079448199171"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Neurosciences","Bioelectronic Medicine, Wireless, Ultra-wideband, Implantable device, Telemetry, Neural recording, Peripheral nerve, Vagus nerve"],"dc:title":["A Miniature Wireless Neural Recording and Stimulating System for Chronic Implantation in Freely Moving Animals"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:48:39Z"}