{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1557870495018474"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1557870495018474","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Toxic Gas and Particulates Characterization in a Smoke Density Chamber","abstract":"Smoke and toxic gas inhalation is a major cause of civilian and firefighter deaths during a fire incident. Real-time measurements of the concentrations of particulates and toxic gases in a smoke density chamber have been made using a tapered element oscillating microbalance (TEOM) dust monitor, a Fourier transform infrared (FTIR) gas analyzer, and a hand-held particulate/gas sensor prototype (O2, CO, and hydrocarbons) under development. The FTIR analyzes a total of 21 toxic gases, including both asphyxiants (CO, HCN, etc.) and irritants (HCl, HBr, acrolein, formaldehyde, etc.). Common building materials, plastics, and selected woods at various moisture contents are used as the fuel. A specimen is placed vertically or horizontally and heated with an incident radiant flux of 25 kW/m2 under a flaming or non-flaming condition. The smoke obscurity and the particulate mass concentration correlate well with live readings of the CO concentration. The prototype device for fire service is being validated by the standard analytical equipment (TEOM and FTIR).","abstract_html":"Smoke and toxic gas inhalation is a major cause of civilian and firefighter deaths during a fire incident. Real-time measurements of the concentrations of particulates and toxic gases in a smoke density chamber have been made using a tapered element oscillating microbalance (TEOM) dust monitor, a Fourier transform infrared (FTIR) gas analyzer, and a hand-held particulate/gas sensor prototype (O2, CO, and hydrocarbons) under development. The FTIR analyzes a total of 21 toxic gases, including both asphyxiants (CO, HCN, etc.) and irritants (HCl, HBr, acrolein, formaldehyde, etc.). Common building materials, plastics, and selected woods at various moisture contents are used as the fuel. A specimen is placed vertically or horizontally and heated with an incident radiant flux of 25 kW/m2 under a flaming or non-flaming condition. The smoke obscurity and the particulate mass concentration correlate well with live readings of the CO concentration. The prototype device for fire service is being validated by the standard analytical equipment (TEOM and FTIR).","abstract_has_math":false,"creators":["Matsuyama, Yumi"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Takahashi, Fumiaki"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05-23","date_published":"2019-05-23","updated_at":"2026-11-27T04:49:11Z","subjects":["Mechanical Engineering","Engineering","Fire toxicity, Smoke obscurity, Wood pyrolysis, Moisture content, Carbon monoxide, Acrolein, Formaldehyde"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1557870495018474","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1557870495018474","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1557870495018474","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1557870495018474","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Takahashi, Fumiaki"]},{"key":"dc:creator","label":"Author","values":["Matsuyama, Yumi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-05-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Engineering","Fire toxicity, Smoke obscurity, Wood pyrolysis, Moisture content, Carbon monoxide, Acrolein, Formaldehyde"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1557870495018474"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Smoke and toxic gas inhalation is a major cause of civilian and firefighter deaths during a fire incident. Real-time measurements of the concentrations of particulates and toxic gases in a smoke density chamber have been made using a tapered element oscillating microbalance (TEOM) dust monitor, a Fourier transform infrared (FTIR) gas analyzer, and a hand-held particulate/gas sensor prototype (O2, CO, and hydrocarbons) under development. The FTIR analyzes a total of 21 toxic gases, including both asphyxiants (CO, HCN, etc.) and irritants (HCl, HBr, acrolein, formaldehyde, etc.). Common building materials, plastics, and selected woods at various moisture contents are used as the fuel. A specimen is placed vertically or horizontally and heated with an incident radiant flux of 25 kW/m2 under a flaming or non-flaming condition. The smoke obscurity and the particulate mass concentration correlate well with live readings of the CO concentration. The prototype device for fire service is being validated by the standard analytical equipment (TEOM and FTIR)."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","8.84 MB"]},{"key":"dc:title","label":"Title","values":["Toxic Gas and Particulates Characterization in a Smoke Density Chamber"]}]}],"canonical_facts":{"dc:contributor.advisor":["Takahashi, Fumiaki"],"dc:creator":["Matsuyama, Yumi"],"dc:date":["2019-05-23"],"dc:description":["Smoke and toxic gas inhalation is a major cause of civilian and firefighter deaths during a fire incident. Real-time measurements of the concentrations of particulates and toxic gases in a smoke density chamber have been made using a tapered element oscillating microbalance (TEOM) dust monitor, a Fourier transform infrared (FTIR) gas analyzer, and a hand-held particulate/gas sensor prototype (O2, CO, and hydrocarbons) under development. The FTIR analyzes a total of 21 toxic gases, including both asphyxiants (CO, HCN, etc.) and irritants (HCl, HBr, acrolein, formaldehyde, etc.). Common building materials, plastics, and selected woods at various moisture contents are used as the fuel. A specimen is placed vertically or horizontally and heated with an incident radiant flux of 25 kW/m2 under a flaming or non-flaming condition. The smoke obscurity and the particulate mass concentration correlate well with live readings of the CO concentration. The prototype device for fire service is being validated by the standard analytical equipment (TEOM and FTIR)."],"dc:format":["application/pdf","8.84 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1557870495018474"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Engineering","Fire toxicity, Smoke obscurity, Wood pyrolysis, Moisture content, Carbon monoxide, Acrolein, Formaldehyde"],"dc:title":["Toxic Gas and Particulates Characterization in a Smoke Density Chamber"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:11Z"}