{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1560241654377726"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1560241654377726","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"NUMERICAL STUDY OF FIRE BEHAVIOR BETWEEN TWO INCLINED PANELS","abstract":"Solar panels installed on residential rooftops have gained popularity because of their economic efficiency as well as environmental friendliness. However, this type of installation affects the fire performance on the rooftop and introduces new fire concerns. To gain a fundamental understanding of this process, a gas burner fire over an inclined surface (90 cm wide and 440 cm long) with and without a parallel top panel is numerically simulated using FireFOAM. Cases with three different inter-panel distances (6.25 cm, 12.5 cm, and 25 cm) and a case without the top panel are simulated. The results show that the top panel has multiple effects on the fire behaviors. First, it reflects and increases the radiative heat input on the bottom panel. Second, it confines the flow between the two panels and forces the flame to stay close to the bottom panel, increasing the conductive heat flux onto the bottom panel. Third, the top panel reduces the fresh air (oxygen) that enters the fire domain. When the equivalence ratio drops below one, this effect impedes the gas-phase reaction and decreases the gas-phase temperature, and hence the heat flux on the lower panel. As a result of these effects, the flame temperature and heat flux on the lower panel first increases and then decreases when the inter-panel distance decreases. Physics-based mitigation strategies are proposed and shown effective to alleviate the adverse effects of the solar panels on the rooftop fire performance.","abstract_html":"Solar panels installed on residential rooftops have gained popularity because of their economic efficiency as well as environmental friendliness. However, this type of installation affects the fire performance on the rooftop and introduces new fire concerns. To gain a fundamental understanding of this process, a gas burner fire over an inclined surface (90 cm wide and 440 cm long) with and without a parallel top panel is numerically simulated using FireFOAM. Cases with three different inter-panel distances (6.25 cm, 12.5 cm, and 25 cm) and a case without the top panel are simulated. The results show that the top panel has multiple effects on the fire behaviors. First, it reflects and increases the radiative heat input on the bottom panel. Second, it confines the flow between the two panels and forces the flame to stay close to the bottom panel, increasing the conductive heat flux onto the bottom panel. Third, the top panel reduces the fresh air (oxygen) that enters the fire domain. When the equivalence ratio drops below one, this effect impedes the gas-phase reaction and decreases the gas-phase temperature, and hence the heat flux on the lower panel. As a result of these effects, the flame temperature and heat flux on the lower panel first increases and then decreases when the inter-panel distance decreases. Physics-based mitigation strategies are proposed and shown effective to alleviate the adverse effects of the solar panels on the rooftop fire performance.","abstract_has_math":false,"creators":["Li, Qian"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Liao, Ya-ting"],"committee_members":[],"year":2019,"date_issued":"2019-08-28","date_published":"2019-08-28","updated_at":"2026-11-27T04:49:15Z","subjects":["Mechanical Engineering","concurrent flame spread","confinement flame","PV panel fires"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1560241654377726","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1560241654377726","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1560241654377726","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1560241654377726","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Liao, Ya-ting"]},{"key":"dc:creator","label":"Author","values":["Li, Qian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-08-28"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","concurrent flame spread","confinement flame","PV panel fires"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1560241654377726"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Solar panels installed on residential rooftops have gained popularity because of their economic efficiency as well as environmental friendliness. However, this type of installation affects the fire performance on the rooftop and introduces new fire concerns. To gain a fundamental understanding of this process, a gas burner fire over an inclined surface (90 cm wide and 440 cm long) with and without a parallel top panel is numerically simulated using FireFOAM. Cases with three different inter-panel distances (6.25 cm, 12.5 cm, and 25 cm) and a case without the top panel are simulated. The results show that the top panel has multiple effects on the fire behaviors. First, it reflects and increases the radiative heat input on the bottom panel. Second, it confines the flow between the two panels and forces the flame to stay close to the bottom panel, increasing the conductive heat flux onto the bottom panel. Third, the top panel reduces the fresh air (oxygen) that enters the fire domain. When the equivalence ratio drops below one, this effect impedes the gas-phase reaction and decreases the gas-phase temperature, and hence the heat flux on the lower panel. As a result of these effects, the flame temperature and heat flux on the lower panel first increases and then decreases when the inter-panel distance decreases. Physics-based mitigation strategies are proposed and shown effective to alleviate the adverse effects of the solar panels on the rooftop fire performance."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.100","5.13 MB"]},{"key":"dc:title","label":"Title","values":["NUMERICAL STUDY OF FIRE BEHAVIOR BETWEEN TWO INCLINED PANELS"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Liao, Ya-ting"],"dc:creator":["Li, Qian"],"dc:date":["2019-08-28"],"dc:description":["Solar panels installed on residential rooftops have gained popularity because of their economic efficiency as well as environmental friendliness. However, this type of installation affects the fire performance on the rooftop and introduces new fire concerns. To gain a fundamental understanding of this process, a gas burner fire over an inclined surface (90 cm wide and 440 cm long) with and without a parallel top panel is numerically simulated using FireFOAM. Cases with three different inter-panel distances (6.25 cm, 12.5 cm, and 25 cm) and a case without the top panel are simulated. The results show that the top panel has multiple effects on the fire behaviors. First, it reflects and increases the radiative heat input on the bottom panel. Second, it confines the flow between the two panels and forces the flame to stay close to the bottom panel, increasing the conductive heat flux onto the bottom panel. Third, the top panel reduces the fresh air (oxygen) that enters the fire domain. When the equivalence ratio drops below one, this effect impedes the gas-phase reaction and decreases the gas-phase temperature, and hence the heat flux on the lower panel. As a result of these effects, the flame temperature and heat flux on the lower panel first increases and then decreases when the inter-panel distance decreases. Physics-based mitigation strategies are proposed and shown effective to alleviate the adverse effects of the solar panels on the rooftop fire performance."],"dc:format":["application/pdf","p.100","5.13 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1560241654377726"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","concurrent flame spread","confinement flame","PV panel fires"],"dc:title":["NUMERICAL STUDY OF FIRE BEHAVIOR BETWEEN TWO INCLINED PANELS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:15Z"}