{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1564763825566542"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1564763825566542","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Lifetime Performance Modeling of Commercial Photovoltaic Power Plants","abstract":"In this work, we introduce a solar power plant performance analysis tool, with an emphasis on the evaluation commercial systems. This pipeline tool is designed for ease of use and fast, reproducible results from a variety of different evaluation techniques that can be run on local computers or with distributed processing. A data set of 98 commercial inverters that have been operating for between 3.5 and 6 years is used as a demonstration of the pipeline features and as a comparison between different analysis methods. Several different types of data filters are applied, along with a clearsky detection algorithm using weather data modeled from satellite images. Comparisons between sensor and satellite based irradiance data show a tendency for the satellite data to under-predict the ground sensor irradiance by 1-2%. Comparing the sensor and satellite data deviations over time shows evidence of sensor drifting in 3 of the 8 sites analyzed. PV performance is modeled as both linear and non-linear performance loss rates (PLR), using regression models and performance ratios to correct the power for weatherconditions. PLR results show data driven models with less data filtering produce more consistent results between different PLR evaluation methods and magnitudes that are reasonable for modern systems, around 0.5-0.7%/year power loss. Non-linear PLR modeling of the oldest (6 years) inverters in the data set shows trends of initial power loss within the first few months of operation, followed by a stable period with little to no loss, ending with higher loss at the end of the time series.","abstract_html":"In this work, we introduce a solar power plant performance analysis tool, with an emphasis on the evaluation commercial systems. This pipeline tool is designed for ease of use and fast, reproducible results from a variety of different evaluation techniques that can be run on local computers or with distributed processing. A data set of 98 commercial inverters that have been operating for between 3.5 and 6 years is used as a demonstration of the pipeline features and as a comparison between different analysis methods. Several different types of data filters are applied, along with a clearsky detection algorithm using weather data modeled from satellite images. Comparisons between sensor and satellite based irradiance data show a tendency for the satellite data to under-predict the ground sensor irradiance by 1-2%. Comparing the sensor and satellite data deviations over time shows evidence of sensor drifting in 3 of the 8 sites analyzed. PV performance is modeled as both linear and non-linear performance loss rates (PLR), using regression models and performance ratios to correct the power for weatherconditions. PLR results show data driven models with less data filtering produce more consistent results between different PLR evaluation methods and magnitudes that are reasonable for modern systems, around 0.5-0.7%/year power loss. Non-linear PLR modeling of the oldest (6 years) inverters in the data set shows trends of initial power loss within the first few months of operation, followed by a stable period with little to no loss, ending with higher loss at the end of the time series.","abstract_has_math":false,"creators":["Curran, Alan J."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["French, Roger"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08-26","date_published":"2019-08-26","updated_at":"2026-11-27T04:49:28Z","subjects":["Materials Science","Engineering","Energy","Photovoltaics","Reliability","Degradation","Data Science","Inverter","Solar","Renewable"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1564763825566542","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1564763825566542","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1564763825566542","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1564763825566542","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["French, Roger"]},{"key":"dc:creator","label":"Author","values":["Curran, Alan J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-08-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science","Engineering","Energy","Photovoltaics","Reliability","Degradation","Data Science","Inverter","Solar","Renewable"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1564763825566542"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this work, we introduce a solar power plant performance analysis tool, with an emphasis on the evaluation commercial systems. This pipeline tool is designed for ease of use and fast, reproducible results from a variety of different evaluation techniques that can be run on local computers or with distributed processing. A data set of 98 commercial inverters that have been operating for between 3.5 and 6 years is used as a demonstration of the pipeline features and as a comparison between different analysis methods. Several different types of data filters are applied, along with a clearsky detection algorithm using weather data modeled from satellite images. Comparisons between sensor and satellite based irradiance data show a tendency for the satellite data to under-predict the ground sensor irradiance by 1-2%. Comparing the sensor and satellite data deviations over time shows evidence of sensor drifting in 3 of the 8 sites analyzed. PV performance is modeled as both linear and non-linear performance loss rates (PLR), using regression models and performance ratios to correct the power for weatherconditions. PLR results show data driven models with less data filtering produce more consistent results between different PLR evaluation methods and magnitudes that are reasonable for modern systems, around 0.5-0.7%/year power loss. Non-linear PLR modeling of the oldest (6 years) inverters in the data set shows trends of initial power loss within the first few months of operation, followed by a stable period with little to no loss, ending with higher loss at the end of the time series."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.124","3.99 MB"]},{"key":"dc:title","label":"Title","values":["Lifetime Performance Modeling of Commercial Photovoltaic Power Plants"]}]}],"canonical_facts":{"dc:contributor.advisor":["French, Roger"],"dc:creator":["Curran, Alan J."],"dc:date":["2019-08-26"],"dc:description":["In this work, we introduce a solar power plant performance analysis tool, with an emphasis on the evaluation commercial systems. This pipeline tool is designed for ease of use and fast, reproducible results from a variety of different evaluation techniques that can be run on local computers or with distributed processing. A data set of 98 commercial inverters that have been operating for between 3.5 and 6 years is used as a demonstration of the pipeline features and as a comparison between different analysis methods. Several different types of data filters are applied, along with a clearsky detection algorithm using weather data modeled from satellite images. Comparisons between sensor and satellite based irradiance data show a tendency for the satellite data to under-predict the ground sensor irradiance by 1-2%. Comparing the sensor and satellite data deviations over time shows evidence of sensor drifting in 3 of the 8 sites analyzed. PV performance is modeled as both linear and non-linear performance loss rates (PLR), using regression models and performance ratios to correct the power for weatherconditions. PLR results show data driven models with less data filtering produce more consistent results between different PLR evaluation methods and magnitudes that are reasonable for modern systems, around 0.5-0.7%/year power loss. Non-linear PLR modeling of the oldest (6 years) inverters in the data set shows trends of initial power loss within the first few months of operation, followed by a stable period with little to no loss, ending with higher loss at the end of the time series."],"dc:format":["application/pdf","p.124","3.99 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1564763825566542"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Materials Science","Engineering","Energy","Photovoltaics","Reliability","Degradation","Data Science","Inverter","Solar","Renewable"],"dc:title":["Lifetime Performance Modeling of Commercial Photovoltaic Power Plants"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:28Z"}