{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1576609767744357"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1576609767744357","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Comparison of Different Transmission Approaches to Optimize Exoskeleton Efficiency","abstract":"This thesis compares two transmissions for use in powered joints of an exoskeleton that successfully integrates with muscle-generated movement. The units use the same motor and brake, but different transmissions. They were designed, built, and tested to evaluate transmission efficiency and passive resistance to optimize future systems that integrate motors with muscle-generated movement. One module incorporated a strain-wave transmission by Harmonic Drive (50:1 gear ratio), while the other implemented a multi-stage planetary gearbox developed by our team (47.29:1). The planetary unit had a mechanical efficiency of approximately 65 percent at 300 degrees per second of output rotational velocity, and only a small fall-off from zero to 300 degrees per second. The harmonic unit had a mechanical efficiency of just under 20 percent at the same output speed, and a sharp fall-off for the same range. Additionally, the planetary transmission provided a 45.1 percent decrease in frictional torque resistance compared to the harmonic device.","abstract_html":"This thesis compares two transmissions for use in powered joints of an exoskeleton that successfully integrates with muscle-generated movement. The units use the same motor and brake, but different transmissions. They were designed, built, and tested to evaluate transmission efficiency and passive resistance to optimize future systems that integrate motors with muscle-generated movement. One module incorporated a strain-wave transmission by Harmonic Drive (50:1 gear ratio), while the other implemented a multi-stage planetary gearbox developed by our team (47.29:1). The planetary unit had a mechanical efficiency of approximately 65 percent at 300 degrees per second of output rotational velocity, and only a small fall-off from zero to 300 degrees per second. The harmonic unit had a mechanical efficiency of just under 20 percent at the same output speed, and a sharp fall-off for the same range. Additionally, the planetary transmission provided a 45.1 percent decrease in frictional torque resistance compared to the harmonic device.","abstract_has_math":false,"creators":["Heebner, Maryellen"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Quinn, Roger"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-01-28","date_published":"2020-01-28","updated_at":"2026-11-27T04:49:37Z","subjects":["Biomechanics","Mechanical Engineering","Lower Extremity Exoskeleton","SCI","Spinal Cord Injury","Powered Knee Joint"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1576609767744357","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1576609767744357","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1576609767744357","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1576609767744357","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Quinn, Roger"]},{"key":"dc:creator","label":"Author","values":["Heebner, Maryellen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-01-28"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","Mechanical Engineering","Lower Extremity Exoskeleton","SCI","Spinal Cord Injury","Powered Knee Joint"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1576609767744357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis compares two transmissions for use in powered joints of an exoskeleton that successfully integrates with muscle-generated movement. The units use the same motor and brake, but different transmissions. They were designed, built, and tested to evaluate transmission efficiency and passive resistance to optimize future systems that integrate motors with muscle-generated movement. One module incorporated a strain-wave transmission by Harmonic Drive (50:1 gear ratio), while the other implemented a multi-stage planetary gearbox developed by our team (47.29:1). The planetary unit had a mechanical efficiency of approximately 65 percent at 300 degrees per second of output rotational velocity, and only a small fall-off from zero to 300 degrees per second. The harmonic unit had a mechanical efficiency of just under 20 percent at the same output speed, and a sharp fall-off for the same range. Additionally, the planetary transmission provided a 45.1 percent decrease in frictional torque resistance compared to the harmonic device."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.73","2.27 MB"]},{"key":"dc:title","label":"Title","values":["Comparison of Different Transmission Approaches to Optimize Exoskeleton Efficiency"]}]}],"canonical_facts":{"dc:contributor.advisor":["Quinn, Roger"],"dc:creator":["Heebner, Maryellen"],"dc:date":["2020-01-28"],"dc:description":["This thesis compares two transmissions for use in powered joints of an exoskeleton that successfully integrates with muscle-generated movement. The units use the same motor and brake, but different transmissions. They were designed, built, and tested to evaluate transmission efficiency and passive resistance to optimize future systems that integrate motors with muscle-generated movement. One module incorporated a strain-wave transmission by Harmonic Drive (50:1 gear ratio), while the other implemented a multi-stage planetary gearbox developed by our team (47.29:1). The planetary unit had a mechanical efficiency of approximately 65 percent at 300 degrees per second of output rotational velocity, and only a small fall-off from zero to 300 degrees per second. The harmonic unit had a mechanical efficiency of just under 20 percent at the same output speed, and a sharp fall-off for the same range. Additionally, the planetary transmission provided a 45.1 percent decrease in frictional torque resistance compared to the harmonic device."],"dc:format":["application/pdf","p.73","2.27 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1576609767744357"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Biomechanics","Mechanical Engineering","Lower Extremity Exoskeleton","SCI","Spinal Cord Injury","Powered Knee Joint"],"dc:title":["Comparison of Different Transmission Approaches to Optimize Exoskeleton Efficiency"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:37Z"}