{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1586361699051386"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1586361699051386","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Modified Cyclodextrin Microparticles to Improve PMMA Drug Delivery Without Mechanical Loss","abstract":"Antibiotic-loaded poly(methyl methacrylate) (PMMA) cement is commonly used as a local delivery system to treat and prevent orthopedic infections associated with arthroplasties in load-bearing applications. However, these delivery systems are inefficient as release rate sharply declines to subinhibitory levels. Prior studies have shown that by adding in drug-filled cyclodextrin (CD) microparticles into PMMA cement, a more consistent release was observed. Additionally, antibiotic refilling through simulated implantation was achieved, but a loss in mechanical properties was noticed. In order to decrease the mechanical loss, modified CD microparticles (PMMA-CD) were synthesized. The compressive strengths, handling characteristics, and refilling ability of PMMA with PMMA-CD were evaluated. Up to a 10% increase in compressive strength was observed when CD was substituted with PMMA-CD. A longer working time and lower maximum temperature were observed with both the addition of CD and of PMMA-CD into PMMA, and refilling was also observed in PMMA with PMMA-CD.","abstract_html":"Antibiotic-loaded poly(methyl methacrylate) (PMMA) cement is commonly used as a local delivery system to treat and prevent orthopedic infections associated with arthroplasties in load-bearing applications. However, these delivery systems are inefficient as release rate sharply declines to subinhibitory levels. Prior studies have shown that by adding in drug-filled cyclodextrin (CD) microparticles into PMMA cement, a more consistent release was observed. Additionally, antibiotic refilling through simulated implantation was achieved, but a loss in mechanical properties was noticed. In order to decrease the mechanical loss, modified CD microparticles (PMMA-CD) were synthesized. The compressive strengths, handling characteristics, and refilling ability of PMMA with PMMA-CD were evaluated. Up to a 10% increase in compressive strength was observed when CD was substituted with PMMA-CD. A longer working time and lower maximum temperature were observed with both the addition of CD and of PMMA-CD into PMMA, and refilling was also observed in PMMA with PMMA-CD.","abstract_has_math":false,"creators":["Lu, Chao-yi"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["von Recum, Horst"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-06-01","date_published":"2020-06-01","updated_at":"2026-11-27T04:49:40Z","subjects":["Biomedical Engineering","Drug delivery","orthopedic infection","polymer","cyclodextrin","PMMA"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1586361699051386","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1586361699051386","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1586361699051386","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1586361699051386","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["von Recum, Horst"]},{"key":"dc:creator","label":"Author","values":["Lu, Chao-yi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-06-01"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Drug delivery","orthopedic infection","polymer","cyclodextrin","PMMA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1586361699051386"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Antibiotic-loaded poly(methyl methacrylate) (PMMA) cement is commonly used as a local delivery system to treat and prevent orthopedic infections associated with arthroplasties in load-bearing applications. However, these delivery systems are inefficient as release rate sharply declines to subinhibitory levels. Prior studies have shown that by adding in drug-filled cyclodextrin (CD) microparticles into PMMA cement, a more consistent release was observed. Additionally, antibiotic refilling through simulated implantation was achieved, but a loss in mechanical properties was noticed. In order to decrease the mechanical loss, modified CD microparticles (PMMA-CD) were synthesized. The compressive strengths, handling characteristics, and refilling ability of PMMA with PMMA-CD were evaluated. Up to a 10% increase in compressive strength was observed when CD was substituted with PMMA-CD. A longer working time and lower maximum temperature were observed with both the addition of CD and of PMMA-CD into PMMA, and refilling was also observed in PMMA with PMMA-CD."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.60","1.06 MB"]},{"key":"dc:title","label":"Title","values":["Modified Cyclodextrin Microparticles to Improve PMMA Drug Delivery Without Mechanical Loss"]}]}],"canonical_facts":{"dc:contributor.advisor":["von Recum, Horst"],"dc:creator":["Lu, Chao-yi"],"dc:date":["2020-06-01"],"dc:description":["Antibiotic-loaded poly(methyl methacrylate) (PMMA) cement is commonly used as a local delivery system to treat and prevent orthopedic infections associated with arthroplasties in load-bearing applications. However, these delivery systems are inefficient as release rate sharply declines to subinhibitory levels. Prior studies have shown that by adding in drug-filled cyclodextrin (CD) microparticles into PMMA cement, a more consistent release was observed. Additionally, antibiotic refilling through simulated implantation was achieved, but a loss in mechanical properties was noticed. In order to decrease the mechanical loss, modified CD microparticles (PMMA-CD) were synthesized. The compressive strengths, handling characteristics, and refilling ability of PMMA with PMMA-CD were evaluated. Up to a 10% increase in compressive strength was observed when CD was substituted with PMMA-CD. A longer working time and lower maximum temperature were observed with both the addition of CD and of PMMA-CD into PMMA, and refilling was also observed in PMMA with PMMA-CD."],"dc:format":["application/pdf","p.60","1.06 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1586361699051386"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Drug delivery","orthopedic infection","polymer","cyclodextrin","PMMA"],"dc:title":["Modified Cyclodextrin Microparticles to Improve PMMA Drug Delivery Without Mechanical Loss"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:40Z"}