{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1586533755964739"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1586533755964739","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Energy Use Intensities across Building Use Types and Climate Zones using the CBECS dataset","abstract":"In this study, we exploredmethods for predicting building natural gas heating use usingelectricity consumption data provided in the CBECS dataset. We performed numerouslayers of subsets and built linear models at each stage predicting natural gas heating energyintensity (EI) as a function of cooling electric EI and electric EUI. We found thatthe R2 values never exceeded 0.1 and concluded that the CBECS dataset lacks sufficientpredictive power for predicting building energy consumption. We applied the Kaiser-Meyer-Olkin test to the CBECS dataset to measure its sampling adequacy and obtaineda value of 0.5 suggesting that it is “miserable” for factor analysis. Recommendationswere made for improving the dataset by adding more predictors and increasing its samplesize. Then, we introduced a novel approach for extracting meaningful informationfrom this noisy dataset by using the Jackknife method for estimating the standard erroron the mean and constructing large-sample confidence intervals on the mean EUIand EIs for various end uses for different building use types located in diverse climatezones. We introduced the concept of distinctly distinguishable climate zone pairings forassessing the influence of climate zone on heating and cooling EI for building use types. In addition, a magnitude-based tiered classification system for EUI and EIs for individualend uses was devised for ranking building use types. We discussed how this systemcan be used to identify and prioritize the targeting of specific areas for energy savingefforts for individual building use types. Retail and education buildings were found toexhibit the highest level of distinguishability, while food service, food sales, and inpatienthealthcare buildings were found to have the highest mean EUIs with 83.4% CIs of[284, 330], [222, 263], and [194, 234] kBtu/sq.ft. respectively.","abstract_html":"In this study, we exploredmethods for predicting building natural gas heating use usingelectricity consumption data provided in the CBECS dataset. We performed numerouslayers of subsets and built linear models at each stage predicting natural gas heating energyintensity (EI) as a function of cooling electric EI and electric EUI. We found thatthe R2 values never exceeded 0.1 and concluded that the CBECS dataset lacks sufficientpredictive power for predicting building energy consumption. We applied the Kaiser-Meyer-Olkin test to the CBECS dataset to measure its sampling adequacy and obtaineda value of 0.5 suggesting that it is “miserable” for factor analysis. Recommendationswere made for improving the dataset by adding more predictors and increasing its samplesize. Then, we introduced a novel approach for extracting meaningful informationfrom this noisy dataset by using the Jackknife method for estimating the standard erroron the mean and constructing large-sample confidence intervals on the mean EUIand EIs for various end uses for different building use types located in diverse climatezones. We introduced the concept of distinctly distinguishable climate zone pairings forassessing the influence of climate zone on heating and cooling EI for building use types. In addition, a magnitude-based tiered classification system for EUI and EIs for individualend uses was devised for ranking building use types. We discussed how this systemcan be used to identify and prioritize the targeting of specific areas for energy savingefforts for individual building use types. Retail and education buildings were found toexhibit the highest level of distinguishability, while food service, food sales, and inpatienthealthcare buildings were found to have the highest mean EUIs with 83.4% CIs of[284, 330], [222, 263], and [194, 234] kBtu/sq.ft. respectively.","abstract_has_math":false,"creators":["Kamath, Shreyas Mandar"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - System and Control Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["French, Roger"],"committee_chairs":["Abramson, Alexis"],"committee_members":[],"year":2020,"date_issued":"2020-06-01","date_published":"2020-06-01","updated_at":"2026-11-27T04:49:42Z","subjects":["Statistics","Energy","buildings, energy, CBECS, EUI, climate zone"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1586533755964739","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1586533755964739","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1586533755964739","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1586533755964739","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["French, Roger"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Abramson, Alexis"]},{"key":"dc:creator","label":"Author","values":["Kamath, Shreyas Mandar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-06-01"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - System and Control Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Statistics","Energy","buildings, energy, CBECS, EUI, climate zone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1586533755964739"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this study, we exploredmethods for predicting building natural gas heating use usingelectricity consumption data provided in the CBECS dataset. We performed numerouslayers of subsets and built linear models at each stage predicting natural gas heating energyintensity (EI) as a function of cooling electric EI and electric EUI. We found thatthe R2 values never exceeded 0.1 and concluded that the CBECS dataset lacks sufficientpredictive power for predicting building energy consumption. We applied the Kaiser-Meyer-Olkin test to the CBECS dataset to measure its sampling adequacy and obtaineda value of 0.5 suggesting that it is “miserable” for factor analysis. Recommendationswere made for improving the dataset by adding more predictors and increasing its samplesize. Then, we introduced a novel approach for extracting meaningful informationfrom this noisy dataset by using the Jackknife method for estimating the standard erroron the mean and constructing large-sample confidence intervals on the mean EUIand EIs for various end uses for different building use types located in diverse climatezones. We introduced the concept of distinctly distinguishable climate zone pairings forassessing the influence of climate zone on heating and cooling EI for building use types. In addition, a magnitude-based tiered classification system for EUI and EIs for individualend uses was devised for ranking building use types. We discussed how this systemcan be used to identify and prioritize the targeting of specific areas for energy savingefforts for individual building use types. Retail and education buildings were found toexhibit the highest level of distinguishability, while food service, food sales, and inpatienthealthcare buildings were found to have the highest mean EUIs with 83.4% CIs of[284, 330], [222, 263], and [194, 234] kBtu/sq.ft. respectively."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.133","12.1 MB"]},{"key":"dc:title","label":"Title","values":["Energy Use Intensities across Building Use Types and Climate Zones using the CBECS dataset"]}]}],"canonical_facts":{"dc:contributor.advisor":["French, Roger"],"dc:contributor.committeechair":["Abramson, Alexis"],"dc:creator":["Kamath, Shreyas Mandar"],"dc:date":["2020-06-01"],"dc:description":["In this study, we exploredmethods for predicting building natural gas heating use usingelectricity consumption data provided in the CBECS dataset. We performed numerouslayers of subsets and built linear models at each stage predicting natural gas heating energyintensity (EI) as a function of cooling electric EI and electric EUI. We found thatthe R2 values never exceeded 0.1 and concluded that the CBECS dataset lacks sufficientpredictive power for predicting building energy consumption. We applied the Kaiser-Meyer-Olkin test to the CBECS dataset to measure its sampling adequacy and obtaineda value of 0.5 suggesting that it is “miserable” for factor analysis. Recommendationswere made for improving the dataset by adding more predictors and increasing its samplesize. Then, we introduced a novel approach for extracting meaningful informationfrom this noisy dataset by using the Jackknife method for estimating the standard erroron the mean and constructing large-sample confidence intervals on the mean EUIand EIs for various end uses for different building use types located in diverse climatezones. We introduced the concept of distinctly distinguishable climate zone pairings forassessing the influence of climate zone on heating and cooling EI for building use types. In addition, a magnitude-based tiered classification system for EUI and EIs for individualend uses was devised for ranking building use types. We discussed how this systemcan be used to identify and prioritize the targeting of specific areas for energy savingefforts for individual building use types. Retail and education buildings were found toexhibit the highest level of distinguishability, while food service, food sales, and inpatienthealthcare buildings were found to have the highest mean EUIs with 83.4% CIs of[284, 330], [222, 263], and [194, 234] kBtu/sq.ft. respectively."],"dc:format":["application/pdf","p.133","12.1 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1586533755964739"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Statistics","Energy","buildings, energy, CBECS, EUI, climate zone"],"dc:title":["Energy Use Intensities across Building Use Types and Climate Zones using the CBECS dataset"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - System and Control Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:49:42Z"}