{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1619622233546762"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1619622233546762","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DEVELOPMENT OF CONTINUOUS MONITORING PULSE OXIMETER DEVICE","abstract":"The rise of wearable technology has enabled continuous fitness and health monitoring. Continuous health monitoring is seen as a very powerful tool for preventative health care. The development of advanced sensors and better devices allow for more comprehensive monitoring and wider adoption. Wearable devices commonly use PPG based pulse oximetry to measure heart rate and oxygen saturation, two very important health metrics, although limitation in their design prevent them from being very practical from a health monitoring perspective. This research presents the design and development of a novel wearable pulse oximeter device that attempts to overcome limitations of existing devices. All aspects of the device design including mechanical form factor, electrical circuit and embedded software are covered in length. The resulting device, Earox, is an ear-based design that clips on the ear lobe to continuously monitor heart rate and oxygen saturation for two weeks on a single charge.","abstract_html":"The rise of wearable technology has enabled continuous fitness and health monitoring. Continuous health monitoring is seen as a very powerful tool for preventative health care. The development of advanced sensors and better devices allow for more comprehensive monitoring and wider adoption. Wearable devices commonly use PPG based pulse oximetry to measure heart rate and oxygen saturation, two very important health metrics, although limitation in their design prevent them from being very practical from a health monitoring perspective. This research presents the design and development of a novel wearable pulse oximeter device that attempts to overcome limitations of existing devices. All aspects of the device design including mechanical form factor, electrical circuit and embedded software are covered in length. The resulting device, Earox, is an ear-based design that clips on the ear lobe to continuously monitor heart rate and oxygen saturation for two weeks on a single charge.","abstract_has_math":false,"creators":["Kayani, Badar Jahangir"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Loparo, Kenneth"],"committee_members":[],"year":2021,"date_issued":"2021-06-21","date_published":"2021-06-21","updated_at":"2026-11-27T04:50:14Z","subjects":["Electrical Engineering","Medical Imaging","pulse, oximeter, device, ble, heart, oxygen, saturation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1619622233546762","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1619622233546762","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1619622233546762","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1619622233546762","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Loparo, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Kayani, Badar Jahangir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-06-21"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Medical Imaging","pulse, oximeter, device, ble, heart, oxygen, saturation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1619622233546762"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The rise of wearable technology has enabled continuous fitness and health monitoring. Continuous health monitoring is seen as a very powerful tool for preventative health care. The development of advanced sensors and better devices allow for more comprehensive monitoring and wider adoption. Wearable devices commonly use PPG based pulse oximetry to measure heart rate and oxygen saturation, two very important health metrics, although limitation in their design prevent them from being very practical from a health monitoring perspective. This research presents the design and development of a novel wearable pulse oximeter device that attempts to overcome limitations of existing devices. All aspects of the device design including mechanical form factor, electrical circuit and embedded software are covered in length. The resulting device, Earox, is an ear-based design that clips on the ear lobe to continuously monitor heart rate and oxygen saturation for two weeks on a single charge."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.126","3.76 MB"]},{"key":"dc:title","label":"Title","values":["DEVELOPMENT OF CONTINUOUS MONITORING PULSE OXIMETER DEVICE"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Loparo, Kenneth"],"dc:creator":["Kayani, Badar Jahangir"],"dc:date":["2021-06-21"],"dc:description":["The rise of wearable technology has enabled continuous fitness and health monitoring. Continuous health monitoring is seen as a very powerful tool for preventative health care. The development of advanced sensors and better devices allow for more comprehensive monitoring and wider adoption. Wearable devices commonly use PPG based pulse oximetry to measure heart rate and oxygen saturation, two very important health metrics, although limitation in their design prevent them from being very practical from a health monitoring perspective. This research presents the design and development of a novel wearable pulse oximeter device that attempts to overcome limitations of existing devices. All aspects of the device design including mechanical form factor, electrical circuit and embedded software are covered in length. The resulting device, Earox, is an ear-based design that clips on the ear lobe to continuously monitor heart rate and oxygen saturation for two weeks on a single charge."],"dc:format":["application/pdf","p.126","3.76 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1619622233546762"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Medical Imaging","pulse, oximeter, device, ble, heart, oxygen, saturation"],"dc:title":["DEVELOPMENT OF CONTINUOUS MONITORING PULSE OXIMETER DEVICE"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:14Z"}