{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1637700407489581"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1637700407489581","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Exoskeleton Design For Cooperative Human/Robot Gait Restoration","abstract":"This dissertation describes the development of a purpose-built, cooperative human/robot exoskeleton system. This was a unique system that was conceived and designed from the beginning as a cooperative system, as opposed to other research efforts that adapted exoskeletons initially designed for function replacement rather than function augmentation. The initial prototype system was developed as a modular exoskeleton using commercially available, off-the-shelf components, including the motor, transmission, and brake. They were integrated with a custom input transmission and aluminum housing. The system was tested on able-bodied users to verify it would be able to handle relatively high speed (1.2 m/s) walking. Metabolic testing was also performed to quantify the importance of joint friction on overall metabolic energy consumption. Testing was also performed on two users with spinal cord injury (SCI). The controller, a feed forward torque bursting controller, was found to increase gait performance.After initial exoskeleton work, custom actuators were developed to identify the ideal architecture for future hybrid systems. Two actuators were developed that used the same motor and similar gear ratios – a commercially available harmonic drive-based transmission, and a custom designed planetary gearbox-based transmission. Both were tested for isometric torque and passive resistance, using the same techniques from initial bench testing the prototype exoskeleton. These test results were then combined to quantify the net torque operating envelope, passive resistance compensation current, and mechanical efficiency. The planetary actuator was found to outperform the harmonic actuator in all categories.Finally, some techniques are presented to allow for quicker design decisions and prototyping. These include tools developed to automate motor selection, transmission design, and fabrication techniques optimized for low volume, high performance prototyping. This work contributed several novel concepts to the overall body of knowledge. The first was an exoskeleton designed specifically for hybrid gait restoration featuring implantable functional neuromuscular stimulation. Secondly, a novel actuator with unique, multistage planetary architecture and joint brake was developed. Both of these efforts demanded the generation of a thorough evaluation process. Human testing and demonstration of a unique, feed forward controller was shown to be effective with 2 users with spinal cord injury.","abstract_html":"This dissertation describes the development of a purpose-built, cooperative human/robot exoskeleton system. This was a unique system that was conceived and designed from the beginning as a cooperative system, as opposed to other research efforts that adapted exoskeletons initially designed for function replacement rather than function augmentation. The initial prototype system was developed as a modular exoskeleton using commercially available, off-the-shelf components, including the motor, transmission, and brake. They were integrated with a custom input transmission and aluminum housing. The system was tested on able-bodied users to verify it would be able to handle relatively high speed (1.2 m/s) walking. Metabolic testing was also performed to quantify the importance of joint friction on overall metabolic energy consumption. Testing was also performed on two users with spinal cord injury (SCI). The controller, a feed forward torque bursting controller, was found to increase gait performance.After initial exoskeleton work, custom actuators were developed to identify the ideal architecture for future hybrid systems. Two actuators were developed that used the same motor and similar gear ratios – a commercially available harmonic drive-based transmission, and a custom designed planetary gearbox-based transmission. Both were tested for isometric torque and passive resistance, using the same techniques from initial bench testing the prototype exoskeleton. These test results were then combined to quantify the net torque operating envelope, passive resistance compensation current, and mechanical efficiency. The planetary actuator was found to outperform the harmonic actuator in all categories.Finally, some techniques are presented to allow for quicker design decisions and prototyping. These include tools developed to automate motor selection, transmission design, and fabrication techniques optimized for low volume, high performance prototyping. This work contributed several novel concepts to the overall body of knowledge. The first was an exoskeleton designed specifically for hybrid gait restoration featuring implantable functional neuromuscular stimulation. Secondly, a novel actuator with unique, multistage planetary architecture and joint brake was developed. Both of these efforts demanded the generation of a thorough evaluation process. Human testing and demonstration of a unique, feed forward controller was shown to be effective with 2 users with spinal cord injury.","abstract_has_math":false,"creators":["NANDOR, MARK"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Quinn, Roger"],"committee_members":[],"year":2022,"date_issued":"2022-01-25","date_published":"2022-01-25","updated_at":"2026-11-27T04:50:29Z","subjects":["Biomedical Engineering","Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1637700407489581","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1637700407489581","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1637700407489581","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1637700407489581","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Quinn, Roger"]},{"key":"dc:creator","label":"Author","values":["NANDOR, MARK"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-01-25"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1637700407489581"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This dissertation describes the development of a purpose-built, cooperative human/robot exoskeleton system. This was a unique system that was conceived and designed from the beginning as a cooperative system, as opposed to other research efforts that adapted exoskeletons initially designed for function replacement rather than function augmentation. The initial prototype system was developed as a modular exoskeleton using commercially available, off-the-shelf components, including the motor, transmission, and brake. They were integrated with a custom input transmission and aluminum housing. The system was tested on able-bodied users to verify it would be able to handle relatively high speed (1.2 m/s) walking. Metabolic testing was also performed to quantify the importance of joint friction on overall metabolic energy consumption. Testing was also performed on two users with spinal cord injury (SCI). The controller, a feed forward torque bursting controller, was found to increase gait performance.After initial exoskeleton work, custom actuators were developed to identify the ideal architecture for future hybrid systems. Two actuators were developed that used the same motor and similar gear ratios – a commercially available harmonic drive-based transmission, and a custom designed planetary gearbox-based transmission. Both were tested for isometric torque and passive resistance, using the same techniques from initial bench testing the prototype exoskeleton. These test results were then combined to quantify the net torque operating envelope, passive resistance compensation current, and mechanical efficiency. The planetary actuator was found to outperform the harmonic actuator in all categories.Finally, some techniques are presented to allow for quicker design decisions and prototyping. These include tools developed to automate motor selection, transmission design, and fabrication techniques optimized for low volume, high performance prototyping. This work contributed several novel concepts to the overall body of knowledge. The first was an exoskeleton designed specifically for hybrid gait restoration featuring implantable functional neuromuscular stimulation. Secondly, a novel actuator with unique, multistage planetary architecture and joint brake was developed. Both of these efforts demanded the generation of a thorough evaluation process. Human testing and demonstration of a unique, feed forward controller was shown to be effective with 2 users with spinal cord injury."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","3.74 MB"]},{"key":"dc:title","label":"Title","values":["Exoskeleton Design For Cooperative Human/Robot Gait Restoration"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Quinn, Roger"],"dc:creator":["NANDOR, MARK"],"dc:date":["2022-01-25"],"dc:description":["This dissertation describes the development of a purpose-built, cooperative human/robot exoskeleton system. This was a unique system that was conceived and designed from the beginning as a cooperative system, as opposed to other research efforts that adapted exoskeletons initially designed for function replacement rather than function augmentation. The initial prototype system was developed as a modular exoskeleton using commercially available, off-the-shelf components, including the motor, transmission, and brake. They were integrated with a custom input transmission and aluminum housing. The system was tested on able-bodied users to verify it would be able to handle relatively high speed (1.2 m/s) walking. Metabolic testing was also performed to quantify the importance of joint friction on overall metabolic energy consumption. Testing was also performed on two users with spinal cord injury (SCI). The controller, a feed forward torque bursting controller, was found to increase gait performance.After initial exoskeleton work, custom actuators were developed to identify the ideal architecture for future hybrid systems. Two actuators were developed that used the same motor and similar gear ratios – a commercially available harmonic drive-based transmission, and a custom designed planetary gearbox-based transmission. Both were tested for isometric torque and passive resistance, using the same techniques from initial bench testing the prototype exoskeleton. These test results were then combined to quantify the net torque operating envelope, passive resistance compensation current, and mechanical efficiency. The planetary actuator was found to outperform the harmonic actuator in all categories.Finally, some techniques are presented to allow for quicker design decisions and prototyping. These include tools developed to automate motor selection, transmission design, and fabrication techniques optimized for low volume, high performance prototyping. This work contributed several novel concepts to the overall body of knowledge. The first was an exoskeleton designed specifically for hybrid gait restoration featuring implantable functional neuromuscular stimulation. Secondly, a novel actuator with unique, multistage planetary architecture and joint brake was developed. Both of these efforts demanded the generation of a thorough evaluation process. Human testing and demonstration of a unique, feed forward controller was shown to be effective with 2 users with spinal cord injury."],"dc:format":["application/pdf","3.74 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1637700407489581"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Mechanical Engineering"],"dc:title":["Exoskeleton Design For Cooperative Human/Robot Gait Restoration"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:29Z"}