{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1638544246538974"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1638544246538974","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Design, Fabrication, and Mechanical Characterization of Novel Rotator Cuff Fixation Methods","abstract":"A rotator cuff tear is one of the most common injuries for the shoulder, and surgical repair is a common treatment method. Re-tearing of the repaired tendon may occur often. Re-tearing is a cheese wiring like phenomenon where the suture material tears through the viscera at the time of suture anastomosis and under tension. It is hypothesized that rotator cuff repair via tendon rivets, or, bone staples would improve mechanical properties compared with a double-row suture anchor technique by increasing contact area between the fixation device and the tendon. This study aims to design prototype rivet and staple anchors to reduce the adverse effects of high tension by reducing local stress. A standardized mechanical test set up was developed using sawbones and rubber strips to compare these attachment methods under comparable test conditions under tension. Samples were monotonically loaded to failure to obtain failure strength, work to failure, and stiffness that are resulting from the repair modality. The results suggest that staple based repair result in notable gains in failure strength and repair stiffness. Further research into utilization of staples in rotator cuff repair is warranted by the results of this thesis that may help prevent re-tears of the rotator cuff because the fixation device can withstand more tension than the surgical sutures currently being used in the practice.","abstract_html":"A rotator cuff tear is one of the most common injuries for the shoulder, and surgical repair is a common treatment method. Re-tearing of the repaired tendon may occur often. Re-tearing is a cheese wiring like phenomenon where the suture material tears through the viscera at the time of suture anastomosis and under tension. It is hypothesized that rotator cuff repair via tendon rivets, or, bone staples would improve mechanical properties compared with a double-row suture anchor technique by increasing contact area between the fixation device and the tendon. This study aims to design prototype rivet and staple anchors to reduce the adverse effects of high tension by reducing local stress. A standardized mechanical test set up was developed using sawbones and rubber strips to compare these attachment methods under comparable test conditions under tension. Samples were monotonically loaded to failure to obtain failure strength, work to failure, and stiffness that are resulting from the repair modality. The results suggest that staple based repair result in notable gains in failure strength and repair stiffness. Further research into utilization of staples in rotator cuff repair is warranted by the results of this thesis that may help prevent re-tears of the rotator cuff because the fixation device can withstand more tension than the surgical sutures currently being used in the practice.","abstract_has_math":false,"creators":["Zhang, Guining"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Akkus, Ozan"],"committee_members":[],"year":2022,"date_issued":"2022-01-25","date_published":"2022-01-25","updated_at":"2026-11-27T04:50:29Z","subjects":["Biomechanics","Biomedical Engineering","Mechanical Engineering","rotator cuff repair","human supraspinatus","rotator cuff tear","shoulder"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1638544246538974","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1638544246538974","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1638544246538974","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1638544246538974","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Akkus, Ozan"]},{"key":"dc:creator","label":"Author","values":["Zhang, Guining"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-01-25"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","Biomedical Engineering","Mechanical Engineering","rotator cuff repair","human supraspinatus","rotator cuff tear","shoulder"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1638544246538974"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A rotator cuff tear is one of the most common injuries for the shoulder, and surgical repair is a common treatment method. Re-tearing of the repaired tendon may occur often. Re-tearing is a cheese wiring like phenomenon where the suture material tears through the viscera at the time of suture anastomosis and under tension. It is hypothesized that rotator cuff repair via tendon rivets, or, bone staples would improve mechanical properties compared with a double-row suture anchor technique by increasing contact area between the fixation device and the tendon. This study aims to design prototype rivet and staple anchors to reduce the adverse effects of high tension by reducing local stress. A standardized mechanical test set up was developed using sawbones and rubber strips to compare these attachment methods under comparable test conditions under tension. Samples were monotonically loaded to failure to obtain failure strength, work to failure, and stiffness that are resulting from the repair modality. The results suggest that staple based repair result in notable gains in failure strength and repair stiffness. Further research into utilization of staples in rotator cuff repair is warranted by the results of this thesis that may help prevent re-tears of the rotator cuff because the fixation device can withstand more tension than the surgical sutures currently being used in the practice."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.77","2.06 MB"]},{"key":"dc:title","label":"Title","values":["The Design, Fabrication, and Mechanical Characterization of Novel Rotator Cuff Fixation Methods"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Akkus, Ozan"],"dc:creator":["Zhang, Guining"],"dc:date":["2022-01-25"],"dc:description":["A rotator cuff tear is one of the most common injuries for the shoulder, and surgical repair is a common treatment method. Re-tearing of the repaired tendon may occur often. Re-tearing is a cheese wiring like phenomenon where the suture material tears through the viscera at the time of suture anastomosis and under tension. It is hypothesized that rotator cuff repair via tendon rivets, or, bone staples would improve mechanical properties compared with a double-row suture anchor technique by increasing contact area between the fixation device and the tendon. This study aims to design prototype rivet and staple anchors to reduce the adverse effects of high tension by reducing local stress. A standardized mechanical test set up was developed using sawbones and rubber strips to compare these attachment methods under comparable test conditions under tension. Samples were monotonically loaded to failure to obtain failure strength, work to failure, and stiffness that are resulting from the repair modality. The results suggest that staple based repair result in notable gains in failure strength and repair stiffness. Further research into utilization of staples in rotator cuff repair is warranted by the results of this thesis that may help prevent re-tears of the rotator cuff because the fixation device can withstand more tension than the surgical sutures currently being used in the practice."],"dc:format":["application/pdf","p.77","2.06 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1638544246538974"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomechanics","Biomedical Engineering","Mechanical Engineering","rotator cuff repair","human supraspinatus","rotator cuff tear","shoulder"],"dc:title":["The Design, Fabrication, and Mechanical Characterization of Novel Rotator Cuff Fixation Methods"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:29Z"}