{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1648124944514679"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1648124944514679","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Exploring Novel Applications of the Radiofrequency (RF) Transmit Chain in Magnetic Resonance Imaging (MRI)","abstract":"MRI is a non-invasive medical imaging modality with many clinical applicationsin major body regions. To generate an MRI image, a RF pulse is first generatedthrough the RF transmit hardware, and the resulting MR signal is subsequently acquiredthrough RF receive hardware. While there are many major advances in RFreceive chain, RF transmit chain development has been largely stagnant. Outsideof conventionalRF pulses for exciting magnetization, the RF transmit signals couldhave clinical applications to stimulate RF technology development. This dissertationfocuses on exploring novel applications and technological development of theRF transmit chain to influence MRI acquisition. The following projects composethis exploration, which aims to stimulate new developments in RF technologiesor improve current implementations.First, the RF transmit chain is used as a constant RF signal to create a motionnavigator called Pilot tone (PT) navigator. This navigator is integrated with a fastsimultaneous quantification method calledMagnetic Resonance Fingerprinting(MRF) to create 2D and 3D free-breathing T1 relaxation times, T2 relaxation times,and proton density (M0) maps. This study is a first step to address difficulties associatedwith quantitative abdominal imaging due to motion and long scan timesfrom conventional quantitative methods. Second, the PT navigator is integrated with a quadratic RF (qRF) based MRF sequence for a 2D free-breathing simultaneousquantification of T1 relaxation times, T2 relaxation times, T2* relaxation times,and fat fraction (FF). This study provides a more comprehensive 2D free-breathingabdominal technique. Third, an old RF engineering concept called outphasing, isintroduced to integrate with current hardware to improve the dynamic range ofsmall amplitude pulses. This control technique serves as the cornerstone of otherprojects with future digital compatibility and high controllability, which will allowgenerating RF pulses beyond conventional ways. The fourth project presents a dedicatedRF transmit hardware for Continuous Arterial Spin Labeling (CASL) with aseparate transmitter coil, a novel way to integrate new RF transmit hardware withperfusion imaging.","abstract_html":"MRI is a non-invasive medical imaging modality with many clinical applicationsin major body regions. To generate an MRI image, a RF pulse is first generatedthrough the RF transmit hardware, and the resulting MR signal is subsequently acquiredthrough RF receive hardware. While there are many major advances in RFreceive chain, RF transmit chain development has been largely stagnant. Outsideof conventionalRF pulses for exciting magnetization, the RF transmit signals couldhave clinical applications to stimulate RF technology development. This dissertationfocuses on exploring novel applications and technological development of theRF transmit chain to influence MRI acquisition. The following projects composethis exploration, which aims to stimulate new developments in RF technologiesor improve current implementations.First, the RF transmit chain is used as a constant RF signal to create a motionnavigator called Pilot tone (PT) navigator. This navigator is integrated with a fastsimultaneous quantification method calledMagnetic Resonance Fingerprinting(MRF) to create 2D and 3D free-breathing T1 relaxation times, T2 relaxation times,and proton density (M0) maps. This study is a first step to address difficulties associatedwith quantitative abdominal imaging due to motion and long scan timesfrom conventional quantitative methods. Second, the PT navigator is integrated with a quadratic RF (qRF) based MRF sequence for a 2D free-breathing simultaneousquantification of T1 relaxation times, T2 relaxation times, T2* relaxation times,and fat fraction (FF). This study provides a more comprehensive 2D free-breathingabdominal technique. Third, an old RF engineering concept called outphasing, isintroduced to integrate with current hardware to improve the dynamic range ofsmall amplitude pulses. This control technique serves as the cornerstone of otherprojects with future digital compatibility and high controllability, which will allowgenerating RF pulses beyond conventional ways. The fourth project presents a dedicatedRF transmit hardware for Continuous Arterial Spin Labeling (CASL) with aseparate transmitter coil, a novel way to integrate new RF transmit hardware withperfusion imaging.","abstract_has_math":false,"creators":["Huang, Sherry Shuying"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Griswold, Mark"],"committee_chairs":["Yu, Xin"],"committee_members":[],"year":2022,"date_issued":"2022-05-23","date_published":"2022-05-23","updated_at":"2026-11-27T04:50:35Z","subjects":["Biomedical Engineering","Radiology","Quantitative MRI","MRF","Motion Compensation","RF Amplifier","CMCD Amplifier"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1648124944514679","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1648124944514679","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1648124944514679","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1648124944514679","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Griswold, Mark"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Yu, Xin"]},{"key":"dc:creator","label":"Author","values":["Huang, Sherry Shuying"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-05-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Radiology","Quantitative MRI","MRF","Motion Compensation","RF Amplifier","CMCD Amplifier"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1648124944514679"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["MRI is a non-invasive medical imaging modality with many clinical applicationsin major body regions. To generate an MRI image, a RF pulse is first generatedthrough the RF transmit hardware, and the resulting MR signal is subsequently acquiredthrough RF receive hardware. While there are many major advances in RFreceive chain, RF transmit chain development has been largely stagnant. Outsideof conventionalRF pulses for exciting magnetization, the RF transmit signals couldhave clinical applications to stimulate RF technology development. This dissertationfocuses on exploring novel applications and technological development of theRF transmit chain to influence MRI acquisition. The following projects composethis exploration, which aims to stimulate new developments in RF technologiesor improve current implementations.First, the RF transmit chain is used as a constant RF signal to create a motionnavigator called Pilot tone (PT) navigator. This navigator is integrated with a fastsimultaneous quantification method calledMagnetic Resonance Fingerprinting(MRF) to create 2D and 3D free-breathing T1 relaxation times, T2 relaxation times,and proton density (M0) maps. This study is a first step to address difficulties associatedwith quantitative abdominal imaging due to motion and long scan timesfrom conventional quantitative methods. Second, the PT navigator is integrated with a quadratic RF (qRF) based MRF sequence for a 2D free-breathing simultaneousquantification of T1 relaxation times, T2 relaxation times, T2* relaxation times,and fat fraction (FF). This study provides a more comprehensive 2D free-breathingabdominal technique. Third, an old RF engineering concept called outphasing, isintroduced to integrate with current hardware to improve the dynamic range ofsmall amplitude pulses. This control technique serves as the cornerstone of otherprojects with future digital compatibility and high controllability, which will allowgenerating RF pulses beyond conventional ways. The fourth project presents a dedicatedRF transmit hardware for Continuous Arterial Spin Labeling (CASL) with aseparate transmitter coil, a novel way to integrate new RF transmit hardware withperfusion imaging."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.114","67.96 MB"]},{"key":"dc:title","label":"Title","values":["Exploring Novel Applications of the Radiofrequency (RF) Transmit Chain in Magnetic Resonance Imaging (MRI)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Griswold, Mark"],"dc:contributor.committeechair":["Yu, Xin"],"dc:creator":["Huang, Sherry Shuying"],"dc:date":["2022-05-23"],"dc:description":["MRI is a non-invasive medical imaging modality with many clinical applicationsin major body regions. To generate an MRI image, a RF pulse is first generatedthrough the RF transmit hardware, and the resulting MR signal is subsequently acquiredthrough RF receive hardware. While there are many major advances in RFreceive chain, RF transmit chain development has been largely stagnant. Outsideof conventionalRF pulses for exciting magnetization, the RF transmit signals couldhave clinical applications to stimulate RF technology development. This dissertationfocuses on exploring novel applications and technological development of theRF transmit chain to influence MRI acquisition. The following projects composethis exploration, which aims to stimulate new developments in RF technologiesor improve current implementations.First, the RF transmit chain is used as a constant RF signal to create a motionnavigator called Pilot tone (PT) navigator. This navigator is integrated with a fastsimultaneous quantification method calledMagnetic Resonance Fingerprinting(MRF) to create 2D and 3D free-breathing T1 relaxation times, T2 relaxation times,and proton density (M0) maps. This study is a first step to address difficulties associatedwith quantitative abdominal imaging due to motion and long scan timesfrom conventional quantitative methods. Second, the PT navigator is integrated with a quadratic RF (qRF) based MRF sequence for a 2D free-breathing simultaneousquantification of T1 relaxation times, T2 relaxation times, T2* relaxation times,and fat fraction (FF). This study provides a more comprehensive 2D free-breathingabdominal technique. Third, an old RF engineering concept called outphasing, isintroduced to integrate with current hardware to improve the dynamic range ofsmall amplitude pulses. This control technique serves as the cornerstone of otherprojects with future digital compatibility and high controllability, which will allowgenerating RF pulses beyond conventional ways. The fourth project presents a dedicatedRF transmit hardware for Continuous Arterial Spin Labeling (CASL) with aseparate transmitter coil, a novel way to integrate new RF transmit hardware withperfusion imaging."],"dc:format":["application/pdf","p.114","67.96 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1648124944514679"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Radiology","Quantitative MRI","MRF","Motion Compensation","RF Amplifier","CMCD Amplifier"],"dc:title":["Exploring Novel Applications of the Radiofrequency (RF) Transmit Chain in Magnetic Resonance Imaging (MRI)"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:35Z"}