{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1648834278008259"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1648834278008259","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Rapid Quantitative Body Magnetic Resonance Imaging","abstract":"Magnetic resonance imaging (MRI) is a non-invasive, effective method for the comprehensive evaluation of disease in the human body. However, abdominal MRI presents many challenges, including the need for a high spatial resolution, large volumetric coverage, and potential for artifacts from respiratory motion. Conventional 3D abdominal quantitative mapping techniques still require breath-holds to yield images free of motion artifact, and the entire dataset can be corrupted if the subject resumes breathing during the acquisition. Furthermore, in many cases, it is not possible to collect “ground truth” images in vivo, simply because standard data collection techniques are too slow to capture images with the resolution and/or coverage of these methods. Magnetic resonance fingerprinting (MRF) is a novel approach that allows simultaneous generation of quantitative maps of multiple tissue parameters and potentially enables the development of standardized imaging biomarkers. However, in order to translate and use MRF for the generation of meaningful imaging biomarkers, the measurement of the mapped quantitative tissue properties must be repeatable and reproducible. Four main projects supporting the improvement of repeatability and reproducibility of abdominal imaging will be described in this dissertation. First, a 4D numerical abdominal phantom which includes the modeling of T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques is presented. Second, a new free breathing method for 3D abdominal T1 mapping is presented. Third, a Gadgetron-based online MRF quantification framework that enables the employment of the technology in a clinical setting is presented. The fourth project presents findings from a multicenter study of repeatability and reproducibility of T1 and T2 maps generated using MRF.","abstract_html":"Magnetic resonance imaging (MRI) is a non-invasive, effective method for the comprehensive evaluation of disease in the human body. However, abdominal MRI presents many challenges, including the need for a high spatial resolution, large volumetric coverage, and potential for artifacts from respiratory motion. Conventional 3D abdominal quantitative mapping techniques still require breath-holds to yield images free of motion artifact, and the entire dataset can be corrupted if the subject resumes breathing during the acquisition. Furthermore, in many cases, it is not possible to collect “ground truth” images in vivo, simply because standard data collection techniques are too slow to capture images with the resolution and/or coverage of these methods. Magnetic resonance fingerprinting (MRF) is a novel approach that allows simultaneous generation of quantitative maps of multiple tissue parameters and potentially enables the development of standardized imaging biomarkers. However, in order to translate and use MRF for the generation of meaningful imaging biomarkers, the measurement of the mapped quantitative tissue properties must be repeatable and reproducible. Four main projects supporting the improvement of repeatability and reproducibility of abdominal imaging will be described in this dissertation. First, a 4D numerical abdominal phantom which includes the modeling of T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques is presented. Second, a new free breathing method for 3D abdominal T1 mapping is presented. Third, a Gadgetron-based online MRF quantification framework that enables the employment of the technology in a clinical setting is presented. The fourth project presents findings from a multicenter study of repeatability and reproducibility of T1 and T2 maps generated using MRF.","abstract_has_math":false,"creators":["Lo, Wei-Ching"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Seiberlich, Nicole"],"committee_chairs":["Yu, Xin"],"committee_members":[],"year":2022,"date_issued":"2022-05-23","date_published":"2022-05-23","updated_at":"2026-11-27T04:50:35Z","subjects":["Biomedical Engineering","Magnetic Resonance Imaging","Magnetic Resonance Fingerprinting"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1648834278008259","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1648834278008259","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1648834278008259","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1648834278008259","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Seiberlich, Nicole"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Yu, Xin"]},{"key":"dc:creator","label":"Author","values":["Lo, Wei-Ching"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-05-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Magnetic Resonance Imaging","Magnetic Resonance Fingerprinting"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1648834278008259"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Magnetic resonance imaging (MRI) is a non-invasive, effective method for the comprehensive evaluation of disease in the human body. However, abdominal MRI presents many challenges, including the need for a high spatial resolution, large volumetric coverage, and potential for artifacts from respiratory motion. Conventional 3D abdominal quantitative mapping techniques still require breath-holds to yield images free of motion artifact, and the entire dataset can be corrupted if the subject resumes breathing during the acquisition. Furthermore, in many cases, it is not possible to collect “ground truth” images in vivo, simply because standard data collection techniques are too slow to capture images with the resolution and/or coverage of these methods. Magnetic resonance fingerprinting (MRF) is a novel approach that allows simultaneous generation of quantitative maps of multiple tissue parameters and potentially enables the development of standardized imaging biomarkers. However, in order to translate and use MRF for the generation of meaningful imaging biomarkers, the measurement of the mapped quantitative tissue properties must be repeatable and reproducible. Four main projects supporting the improvement of repeatability and reproducibility of abdominal imaging will be described in this dissertation. First, a 4D numerical abdominal phantom which includes the modeling of T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques is presented. Second, a new free breathing method for 3D abdominal T1 mapping is presented. Third, a Gadgetron-based online MRF quantification framework that enables the employment of the technology in a clinical setting is presented. The fourth project presents findings from a multicenter study of repeatability and reproducibility of T1 and T2 maps generated using MRF."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.120","4.44 MB"]},{"key":"dc:title","label":"Title","values":["Rapid Quantitative Body Magnetic Resonance Imaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Seiberlich, Nicole"],"dc:contributor.committeechair":["Yu, Xin"],"dc:creator":["Lo, Wei-Ching"],"dc:date":["2022-05-23"],"dc:description":["Magnetic resonance imaging (MRI) is a non-invasive, effective method for the comprehensive evaluation of disease in the human body. However, abdominal MRI presents many challenges, including the need for a high spatial resolution, large volumetric coverage, and potential for artifacts from respiratory motion. Conventional 3D abdominal quantitative mapping techniques still require breath-holds to yield images free of motion artifact, and the entire dataset can be corrupted if the subject resumes breathing during the acquisition. Furthermore, in many cases, it is not possible to collect “ground truth” images in vivo, simply because standard data collection techniques are too slow to capture images with the resolution and/or coverage of these methods. Magnetic resonance fingerprinting (MRF) is a novel approach that allows simultaneous generation of quantitative maps of multiple tissue parameters and potentially enables the development of standardized imaging biomarkers. However, in order to translate and use MRF for the generation of meaningful imaging biomarkers, the measurement of the mapped quantitative tissue properties must be repeatable and reproducible. Four main projects supporting the improvement of repeatability and reproducibility of abdominal imaging will be described in this dissertation. First, a 4D numerical abdominal phantom which includes the modeling of T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques is presented. Second, a new free breathing method for 3D abdominal T1 mapping is presented. Third, a Gadgetron-based online MRF quantification framework that enables the employment of the technology in a clinical setting is presented. The fourth project presents findings from a multicenter study of repeatability and reproducibility of T1 and T2 maps generated using MRF."],"dc:format":["application/pdf","p.120","4.44 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1648834278008259"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Magnetic Resonance Imaging","Magnetic Resonance Fingerprinting"],"dc:title":["Rapid Quantitative Body Magnetic Resonance Imaging"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:35Z"}