{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1656221284850874"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1656221284850874","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System","abstract":"Atrial fibrillation is a common cardiac condition which can place the patient at risk for many serious medical issues. Current interventional procedures employ cardiac ablation catheters guided using x-ray fluoroscopy imaging, which generates restricted two-dimensional images of the heart, and exposes the patient to a high dose of radiation. Three-dimensional catheter position data can be obtained and radiation exposure can be mitigated by using Magnetic Resonance Imaging (MRI) for this procedure. The magnetic field of the MRI machine can be strategically leveraged to steer and actuate a robotic ablation catheter, by energizing small embedded electromagnetic coils within the catheter tip. These coils however, may undesirably interact with the MRI machine’s rotating radio-frequency (RF) magnetic field, potentially leading to excessive heating of the catheter or power supply damage. This thesis aims to characterize the RF response of actuation coils used in a novel MRI guided catheter system, and design an actuation coil set prototype which can safely operate in the MRI environment. The proposed final actuation coil set consists of 3 coils wound over the catheter body, and aims to improve the RF behavior of the coil set by implementing improved design elements such as a new winding pattern, wire gauge variation, and utilization of capacitors within the system. The final prototype presented successfully meetsthe required standards and is able to perform desired actuations.","abstract_html":"Atrial fibrillation is a common cardiac condition which can place the patient at risk for many serious medical issues. Current interventional procedures employ cardiac ablation catheters guided using x-ray fluoroscopy imaging, which generates restricted two-dimensional images of the heart, and exposes the patient to a high dose of radiation. Three-dimensional catheter position data can be obtained and radiation exposure can be mitigated by using Magnetic Resonance Imaging (MRI) for this procedure. The magnetic field of the MRI machine can be strategically leveraged to steer and actuate a robotic ablation catheter, by energizing small embedded electromagnetic coils within the catheter tip. These coils however, may undesirably interact with the MRI machine’s rotating radio-frequency (RF) magnetic field, potentially leading to excessive heating of the catheter or power supply damage. This thesis aims to characterize the RF response of actuation coils used in a novel MRI guided catheter system, and design an actuation coil set prototype which can safely operate in the MRI environment. The proposed final actuation coil set consists of 3 coils wound over the catheter body, and aims to improve the RF behavior of the coil set by implementing improved design elements such as a new winding pattern, wire gauge variation, and utilization of capacitors within the system. The final prototype presented successfully meetsthe required standards and is able to perform desired actuations.","abstract_has_math":false,"creators":["Kamath, Sanjana K."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Cavusoglu, M. Cenk"],"committee_members":[],"year":2022,"date_issued":"2022-08-26","date_published":"2022-08-26","updated_at":"2026-11-27T04:50:43Z","subjects":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Electromagnetics","Electromagnetism","Engineering","Medical Imaging","Robotics","Robots","Surgery","MRI","catheter ablation","cardiac fibrillation","MRI guided catheter","robotic catheter","radio-frequency","RF","micro-coils","microcoils","electromagnetic actuation","electromagnet","actuation","surgical robotics","fibrillation","cardiac catheter","MRI actuated","RF safety"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1656221284850874","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1656221284850874","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1656221284850874","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1656221284850874","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cavusoglu, M. Cenk"]},{"key":"dc:creator","label":"Author","values":["Kamath, Sanjana K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-08-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Electromagnetics","Electromagnetism","Engineering","Medical Imaging","Robotics","Robots","Surgery","MRI","catheter ablation","cardiac fibrillation","MRI guided catheter","robotic catheter","radio-frequency","RF","micro-coils","microcoils","electromagnetic actuation","electromagnet","actuation","surgical robotics","fibrillation","cardiac catheter","MRI actuated","RF safety"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1656221284850874"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Atrial fibrillation is a common cardiac condition which can place the patient at risk for many serious medical issues. Current interventional procedures employ cardiac ablation catheters guided using x-ray fluoroscopy imaging, which generates restricted two-dimensional images of the heart, and exposes the patient to a high dose of radiation. Three-dimensional catheter position data can be obtained and radiation exposure can be mitigated by using Magnetic Resonance Imaging (MRI) for this procedure. The magnetic field of the MRI machine can be strategically leveraged to steer and actuate a robotic ablation catheter, by energizing small embedded electromagnetic coils within the catheter tip. These coils however, may undesirably interact with the MRI machine’s rotating radio-frequency (RF) magnetic field, potentially leading to excessive heating of the catheter or power supply damage. This thesis aims to characterize the RF response of actuation coils used in a novel MRI guided catheter system, and design an actuation coil set prototype which can safely operate in the MRI environment. The proposed final actuation coil set consists of 3 coils wound over the catheter body, and aims to improve the RF behavior of the coil set by implementing improved design elements such as a new winding pattern, wire gauge variation, and utilization of capacitors within the system. The final prototype presented successfully meetsthe required standards and is able to perform desired actuations."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.59","7.95 MB"]},{"key":"dc:title","label":"Title","values":["Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cavusoglu, M. Cenk"],"dc:creator":["Kamath, Sanjana K."],"dc:date":["2022-08-26"],"dc:description":["Atrial fibrillation is a common cardiac condition which can place the patient at risk for many serious medical issues. Current interventional procedures employ cardiac ablation catheters guided using x-ray fluoroscopy imaging, which generates restricted two-dimensional images of the heart, and exposes the patient to a high dose of radiation. Three-dimensional catheter position data can be obtained and radiation exposure can be mitigated by using Magnetic Resonance Imaging (MRI) for this procedure. The magnetic field of the MRI machine can be strategically leveraged to steer and actuate a robotic ablation catheter, by energizing small embedded electromagnetic coils within the catheter tip. These coils however, may undesirably interact with the MRI machine’s rotating radio-frequency (RF) magnetic field, potentially leading to excessive heating of the catheter or power supply damage. This thesis aims to characterize the RF response of actuation coils used in a novel MRI guided catheter system, and design an actuation coil set prototype which can safely operate in the MRI environment. The proposed final actuation coil set consists of 3 coils wound over the catheter body, and aims to improve the RF behavior of the coil set by implementing improved design elements such as a new winding pattern, wire gauge variation, and utilization of capacitors within the system. The final prototype presented successfully meetsthe required standards and is able to perform desired actuations."],"dc:format":["application/pdf","p.59","7.95 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1656221284850874"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Electromagnetics","Electromagnetism","Engineering","Medical Imaging","Robotics","Robots","Surgery","MRI","catheter ablation","cardiac fibrillation","MRI guided catheter","robotic catheter","radio-frequency","RF","micro-coils","microcoils","electromagnetic actuation","electromagnet","actuation","surgical robotics","fibrillation","cardiac catheter","MRI actuated","RF safety"],"dc:title":["Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:43Z"}