{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case165701821381496"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case165701821381496","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Motor Recruitment Properties of 16-Contact Composite Flat Interface Nerve Electrodes (C-FINES) in the Human Upper Extremity","abstract":"The composite flat interface nerve electrode (C-FINE) can be used to functionally activate paralyzed muscles. We evaluated the recruitment properties of 16 contact C-FINEs implanted around the nerves of the right upper extremity of a tetraplegic human participant using pulse width (PW) modulated recruitment curves. Muscle activation was quantified using the electromyographic (EMG) response to twitch activation. Selectivity was defined as the maximum percent activation of a muscle before any other muscle reached a 20% activation threshold. We found that it was possible to selectively activate 24/25 muscles, but that selectivity values ranged widely. We were able to successfully create functional stimulation patterns from the acquired recruitment information. We found cuff-wide trends in activation thresholds that indicate the location of each nerve in its cuff. Due to the differences in activation threshold across each cuff, future characterization work should intelligently vary both PA and PW in order to increase efficiency.","abstract_html":"The composite flat interface nerve electrode (C-FINE) can be used to functionally activate paralyzed muscles. We evaluated the recruitment properties of 16 contact C-FINEs implanted around the nerves of the right upper extremity of a tetraplegic human participant using pulse width (PW) modulated recruitment curves. Muscle activation was quantified using the electromyographic (EMG) response to twitch activation. Selectivity was defined as the maximum percent activation of a muscle before any other muscle reached a 20% activation threshold. We found that it was possible to selectively activate 24/25 muscles, but that selectivity values ranged widely. We were able to successfully create functional stimulation patterns from the acquired recruitment information. We found cuff-wide trends in activation thresholds that indicate the location of each nerve in its cuff. Due to the differences in activation threshold across each cuff, future characterization work should intelligently vary both PA and PW in order to increase efficiency.","abstract_has_math":false,"creators":["Alexander, Benjamin James"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kirsch, Robert"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-08-26","date_published":"2022-08-26","updated_at":"2026-11-27T04:50:43Z","subjects":["Biomedical Engineering","FES","EMG","Tetraplegia","C-FINE","Nerve Cuff Electrodes","Muscle Recruitment"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case165701821381496","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case165701821381496","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase165701821381496","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase165701821381496","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kirsch, Robert"]},{"key":"dc:creator","label":"Author","values":["Alexander, Benjamin James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-08-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","FES","EMG","Tetraplegia","C-FINE","Nerve Cuff Electrodes","Muscle Recruitment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case165701821381496"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The composite flat interface nerve electrode (C-FINE) can be used to functionally activate paralyzed muscles. We evaluated the recruitment properties of 16 contact C-FINEs implanted around the nerves of the right upper extremity of a tetraplegic human participant using pulse width (PW) modulated recruitment curves. Muscle activation was quantified using the electromyographic (EMG) response to twitch activation. Selectivity was defined as the maximum percent activation of a muscle before any other muscle reached a 20% activation threshold. We found that it was possible to selectively activate 24/25 muscles, but that selectivity values ranged widely. We were able to successfully create functional stimulation patterns from the acquired recruitment information. We found cuff-wide trends in activation thresholds that indicate the location of each nerve in its cuff. Due to the differences in activation threshold across each cuff, future characterization work should intelligently vary both PA and PW in order to increase efficiency."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.30","1.1 MB"]},{"key":"dc:title","label":"Title","values":["Motor Recruitment Properties of 16-Contact Composite Flat Interface Nerve Electrodes (C-FINES) in the Human Upper Extremity"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kirsch, Robert"],"dc:creator":["Alexander, Benjamin James"],"dc:date":["2022-08-26"],"dc:description":["The composite flat interface nerve electrode (C-FINE) can be used to functionally activate paralyzed muscles. We evaluated the recruitment properties of 16 contact C-FINEs implanted around the nerves of the right upper extremity of a tetraplegic human participant using pulse width (PW) modulated recruitment curves. Muscle activation was quantified using the electromyographic (EMG) response to twitch activation. Selectivity was defined as the maximum percent activation of a muscle before any other muscle reached a 20% activation threshold. We found that it was possible to selectively activate 24/25 muscles, but that selectivity values ranged widely. We were able to successfully create functional stimulation patterns from the acquired recruitment information. We found cuff-wide trends in activation thresholds that indicate the location of each nerve in its cuff. Due to the differences in activation threshold across each cuff, future characterization work should intelligently vary both PA and PW in order to increase efficiency."],"dc:format":["application/pdf","p.30","1.1 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case165701821381496"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","FES","EMG","Tetraplegia","C-FINE","Nerve Cuff Electrodes","Muscle Recruitment"],"dc:title":["Motor Recruitment Properties of 16-Contact Composite Flat Interface Nerve Electrodes (C-FINES) in the Human Upper Extremity"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:50:43Z"}