{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1674471047838582"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1674471047838582","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Development of a Novel Quantitative Transmission Ultrasound Device for Prostate Cancer Imaging and Targeted Prostate Biopsy","abstract":"Ultrasound tomography (UT), previously shown to have high sensitivity for the diagnosis of breast cancer, provides 360-degree submillimeter-resolution speed-of-sound imaging for tissue characterization. The purpose of this study was to validate UT for the detection of prostate cancer. Following prostate MRI and biopsy, patients with prostate cancer underwent robotic-assisted radical prostatectomy and had their prostates subsequently scanned ex vivo in the UT device. Correlations between pathology and imaging were done using an 18-sector approach comparing UT and MRI images against wholemount histopathology. Across 15 cases on blinded sector-based analysis, UT had a sensitivity of 74% and specificity of 95%, while MRI had a sensitivity of 67% and specificity of 98%. Thus, in this initial series of 15 patients, UT demonstrated equal or better sensitivity for detection of cancer compared with MRI. Future work will assess these findings in a larger cohort, followed by in vivo studies with limited angle UT.","abstract_html":"Ultrasound tomography (UT), previously shown to have high sensitivity for the diagnosis of breast cancer, provides 360-degree submillimeter-resolution speed-of-sound imaging for tissue characterization. The purpose of this study was to validate UT for the detection of prostate cancer. Following prostate MRI and biopsy, patients with prostate cancer underwent robotic-assisted radical prostatectomy and had their prostates subsequently scanned ex vivo in the UT device. Correlations between pathology and imaging were done using an 18-sector approach comparing UT and MRI images against wholemount histopathology. Across 15 cases on blinded sector-based analysis, UT had a sensitivity of 74% and specificity of 95%, while MRI had a sensitivity of 67% and specificity of 98%. Thus, in this initial series of 15 patients, UT demonstrated equal or better sensitivity for detection of cancer compared with MRI. Future work will assess these findings in a larger cohort, followed by in vivo studies with limited angle UT.","abstract_has_math":false,"creators":["Enders, Jacob J."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Fleischman, Aaron"],"committee_members":[],"year":2023,"date_issued":"2023-05-26","date_published":"2023-05-26","updated_at":"2026-11-27T04:58:38Z","subjects":["Biomedical Engineering","Medicine","Prostate cancer, imaging, ultrasound, tomography"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1674471047838582","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1674471047838582","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1674471047838582","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1674471047838582","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Fleischman, Aaron"]},{"key":"dc:creator","label":"Author","values":["Enders, Jacob J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-05-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Medicine","Prostate cancer, imaging, ultrasound, tomography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1674471047838582"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ultrasound tomography (UT), previously shown to have high sensitivity for the diagnosis of breast cancer, provides 360-degree submillimeter-resolution speed-of-sound imaging for tissue characterization. The purpose of this study was to validate UT for the detection of prostate cancer. Following prostate MRI and biopsy, patients with prostate cancer underwent robotic-assisted radical prostatectomy and had their prostates subsequently scanned ex vivo in the UT device. Correlations between pathology and imaging were done using an 18-sector approach comparing UT and MRI images against wholemount histopathology. Across 15 cases on blinded sector-based analysis, UT had a sensitivity of 74% and specificity of 95%, while MRI had a sensitivity of 67% and specificity of 98%. Thus, in this initial series of 15 patients, UT demonstrated equal or better sensitivity for detection of cancer compared with MRI. Future work will assess these findings in a larger cohort, followed by in vivo studies with limited angle UT."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.49","3.92 MB"]},{"key":"dc:title","label":"Title","values":["Development of a Novel Quantitative Transmission Ultrasound Device for Prostate Cancer Imaging and Targeted Prostate Biopsy"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Fleischman, Aaron"],"dc:creator":["Enders, Jacob J."],"dc:date":["2023-05-26"],"dc:description":["Ultrasound tomography (UT), previously shown to have high sensitivity for the diagnosis of breast cancer, provides 360-degree submillimeter-resolution speed-of-sound imaging for tissue characterization. The purpose of this study was to validate UT for the detection of prostate cancer. Following prostate MRI and biopsy, patients with prostate cancer underwent robotic-assisted radical prostatectomy and had their prostates subsequently scanned ex vivo in the UT device. Correlations between pathology and imaging were done using an 18-sector approach comparing UT and MRI images against wholemount histopathology. Across 15 cases on blinded sector-based analysis, UT had a sensitivity of 74% and specificity of 95%, while MRI had a sensitivity of 67% and specificity of 98%. Thus, in this initial series of 15 patients, UT demonstrated equal or better sensitivity for detection of cancer compared with MRI. Future work will assess these findings in a larger cohort, followed by in vivo studies with limited angle UT."],"dc:format":["application/pdf","p.49","3.92 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1674471047838582"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Medicine","Prostate cancer, imaging, ultrasound, tomography"],"dc:title":["Development of a Novel Quantitative Transmission Ultrasound Device for Prostate Cancer Imaging and Targeted Prostate Biopsy"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:58:38Z"}