{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case167654748354951"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case167654748354951","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"SEQUENCE DESIGN AND RECONSTRUCTION OPTIMIZATION FOR TRANSLATION OF MAGNETIC RESONANCE IMAGING","abstract":"Magnetic Resonance Imaging is a clinical imaging modality that has excellent soft tissue contrast, enabling it to answer clinical questions on a range of pathologies that other imaging methods cannot. However, conventional MR techniques typically have slow acquisitions that prevent applications in imaging physiological motion. In addition, other imaging modalities such as CT produce quantitative, reproducible pixel values, whereas MRI generally produces qualitative images. To address these issues, many new MR techniques have been developed but require additional optimization or development to be adopted clinically. Three main projects involving the translation of emerging techniques in MR to clinical application will be described in this thesis. In the first project, a fast imaging technique known as through-time radial GRAPPA is optimized to reduce total acquisition time and reconstruction overhead to enable free-breathing un-gated cardiac CINE. The second project discusses a new quantitative imaging technique in the heart, known as Cardiac Magnetic Resonance Fingerprinting (cMRF), which requires a lengthy dictionary simulation step to be performed with each reconstruction. cMRF dictionary simulation is implemented and optimized on a reconstruction platform known as Gadgetron to enable clinically integration of cMRF. In the final project, in-bore MR-guided prostate biopsy is an interventional technique that requires long T2-weighted imaging. A simulation approach taken to find a faster T2-weighted imaging sequence among Cartesian and spiral TSE sequence variants.","abstract_html":"Magnetic Resonance Imaging is a clinical imaging modality that has excellent soft tissue contrast, enabling it to answer clinical questions on a range of pathologies that other imaging methods cannot. However, conventional MR techniques typically have slow acquisitions that prevent applications in imaging physiological motion. In addition, other imaging modalities such as CT produce quantitative, reproducible pixel values, whereas MRI generally produces qualitative images. To address these issues, many new MR techniques have been developed but require additional optimization or development to be adopted clinically. Three main projects involving the translation of emerging techniques in MR to clinical application will be described in this thesis. In the first project, a fast imaging technique known as through-time radial GRAPPA is optimized to reduce total acquisition time and reconstruction overhead to enable free-breathing un-gated cardiac CINE. The second project discusses a new quantitative imaging technique in the heart, known as Cardiac Magnetic Resonance Fingerprinting (cMRF), which requires a lengthy dictionary simulation step to be performed with each reconstruction. cMRF dictionary simulation is implemented and optimized on a reconstruction platform known as Gadgetron to enable clinically integration of cMRF. In the final project, in-bore MR-guided prostate biopsy is an interventional technique that requires long T2-weighted imaging. A simulation approach taken to find a faster T2-weighted imaging sequence among Cartesian and spiral TSE sequence variants.","abstract_has_math":false,"creators":["Ahad, James N."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Seiberlich, Nicole"],"committee_chairs":["Durand, Dominique"],"committee_members":[],"year":2023,"date_issued":"2023-05-26","date_published":"2023-05-26","updated_at":"2026-11-27T04:58:38Z","subjects":["Biomedical Engineering","Medical Imaging","MRI","MR Physics","Fast Imaging","Parallel Imaging","Cardiac MRI"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case167654748354951","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case167654748354951","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase167654748354951","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase167654748354951","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Seiberlich, Nicole"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Ahad, James N."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-05-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Medical Imaging","MRI","MR Physics","Fast Imaging","Parallel Imaging","Cardiac MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case167654748354951"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Magnetic Resonance Imaging is a clinical imaging modality that has excellent soft tissue contrast, enabling it to answer clinical questions on a range of pathologies that other imaging methods cannot. However, conventional MR techniques typically have slow acquisitions that prevent applications in imaging physiological motion. In addition, other imaging modalities such as CT produce quantitative, reproducible pixel values, whereas MRI generally produces qualitative images. To address these issues, many new MR techniques have been developed but require additional optimization or development to be adopted clinically. Three main projects involving the translation of emerging techniques in MR to clinical application will be described in this thesis. In the first project, a fast imaging technique known as through-time radial GRAPPA is optimized to reduce total acquisition time and reconstruction overhead to enable free-breathing un-gated cardiac CINE. The second project discusses a new quantitative imaging technique in the heart, known as Cardiac Magnetic Resonance Fingerprinting (cMRF), which requires a lengthy dictionary simulation step to be performed with each reconstruction. cMRF dictionary simulation is implemented and optimized on a reconstruction platform known as Gadgetron to enable clinically integration of cMRF. In the final project, in-bore MR-guided prostate biopsy is an interventional technique that requires long T2-weighted imaging. A simulation approach taken to find a faster T2-weighted imaging sequence among Cartesian and spiral TSE sequence variants."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.133","3.16 MB"]},{"key":"dc:title","label":"Title","values":["SEQUENCE DESIGN AND RECONSTRUCTION OPTIMIZATION FOR TRANSLATION OF MAGNETIC RESONANCE IMAGING"]}]}],"canonical_facts":{"dc:contributor.advisor":["Seiberlich, Nicole"],"dc:contributor.committeechair":["Durand, Dominique"],"dc:creator":["Ahad, James N."],"dc:date":["2023-05-26"],"dc:description":["Magnetic Resonance Imaging is a clinical imaging modality that has excellent soft tissue contrast, enabling it to answer clinical questions on a range of pathologies that other imaging methods cannot. However, conventional MR techniques typically have slow acquisitions that prevent applications in imaging physiological motion. In addition, other imaging modalities such as CT produce quantitative, reproducible pixel values, whereas MRI generally produces qualitative images. To address these issues, many new MR techniques have been developed but require additional optimization or development to be adopted clinically. Three main projects involving the translation of emerging techniques in MR to clinical application will be described in this thesis. In the first project, a fast imaging technique known as through-time radial GRAPPA is optimized to reduce total acquisition time and reconstruction overhead to enable free-breathing un-gated cardiac CINE. The second project discusses a new quantitative imaging technique in the heart, known as Cardiac Magnetic Resonance Fingerprinting (cMRF), which requires a lengthy dictionary simulation step to be performed with each reconstruction. cMRF dictionary simulation is implemented and optimized on a reconstruction platform known as Gadgetron to enable clinically integration of cMRF. In the final project, in-bore MR-guided prostate biopsy is an interventional technique that requires long T2-weighted imaging. A simulation approach taken to find a faster T2-weighted imaging sequence among Cartesian and spiral TSE sequence variants."],"dc:format":["application/pdf","p.133","3.16 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case167654748354951"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Medical Imaging","MRI","MR Physics","Fast Imaging","Parallel Imaging","Cardiac MRI"],"dc:title":["SEQUENCE DESIGN AND RECONSTRUCTION OPTIMIZATION FOR TRANSLATION OF MAGNETIC RESONANCE IMAGING"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:58:38Z"}