{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1689632006439284"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1689632006439284","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Effect of Surface Coating and Free End Condition on The Bond Behavior of GFRP Bars Embedded in Concrete","abstract":"Pullout tests on glass fiber-reinforced polymer bar embedded in concrete were performed in accordance with ASTM D7913 [1]. Bars with a nominal diameter of 13 mm (#4) were tested. The bonded length ranged from 5 to 20 times the bar diameter. Specimens were tested with two free end conditions. Those with bar protruding from the bottom (free end) of concrete, and those with bar cut flush with the concrete. The different load responses and peak loads seen indicate that the use of ASTM D7913 [1] to establish a required bond strength for the FRP bars requires further discussion in the research community. Additional tests were performed on concrete slabs reinforced with GFRP bar, serviceability limit states need further discussion to address the crack opening and deflection seen in the slabs reinforced with GFRP.","abstract_html":"Pullout tests on glass fiber-reinforced polymer bar embedded in concrete were performed in accordance with ASTM D7913 [1]. Bars with a nominal diameter of 13 mm (#4) were tested. The bonded length ranged from 5 to 20 times the bar diameter. Specimens were tested with two free end conditions. Those with bar protruding from the bottom (free end) of concrete, and those with bar cut flush with the concrete. The different load responses and peak loads seen indicate that the use of ASTM D7913 [1] to establish a required bond strength for the FRP bars requires further discussion in the research community. Additional tests were performed on concrete slabs reinforced with GFRP bar, serviceability limit states need further discussion to address the crack opening and deflection seen in the slabs reinforced with GFRP.","abstract_has_math":false,"creators":["Cope, Charles Tucker, III"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Carloni, Christian"],"committee_members":[],"year":2023,"date_issued":"2023-08-24","date_published":"2023-08-24","updated_at":"2026-11-27T04:58:57Z","subjects":["Engineering","GFRP","Pull-Out","Reinforced Concrete","ASTM D7913"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1689632006439284","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1689632006439284","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1689632006439284","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1689632006439284","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Carloni, Christian"]},{"key":"dc:creator","label":"Author","values":["Cope, Charles Tucker, III"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-08-24"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","GFRP","Pull-Out","Reinforced Concrete","ASTM D7913"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1689632006439284"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Pullout tests on glass fiber-reinforced polymer bar embedded in concrete were performed in accordance with ASTM D7913 [1]. Bars with a nominal diameter of 13 mm (#4) were tested. The bonded length ranged from 5 to 20 times the bar diameter. Specimens were tested with two free end conditions. Those with bar protruding from the bottom (free end) of concrete, and those with bar cut flush with the concrete. The different load responses and peak loads seen indicate that the use of ASTM D7913 [1] to establish a required bond strength for the FRP bars requires further discussion in the research community. Additional tests were performed on concrete slabs reinforced with GFRP bar, serviceability limit states need further discussion to address the crack opening and deflection seen in the slabs reinforced with GFRP."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.62","49.41 MB"]},{"key":"dc:title","label":"Title","values":["The Effect of Surface Coating and Free End Condition on The Bond Behavior of GFRP Bars Embedded in Concrete"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Carloni, Christian"],"dc:creator":["Cope, Charles Tucker, III"],"dc:date":["2023-08-24"],"dc:description":["Pullout tests on glass fiber-reinforced polymer bar embedded in concrete were performed in accordance with ASTM D7913 [1]. Bars with a nominal diameter of 13 mm (#4) were tested. The bonded length ranged from 5 to 20 times the bar diameter. Specimens were tested with two free end conditions. Those with bar protruding from the bottom (free end) of concrete, and those with bar cut flush with the concrete. The different load responses and peak loads seen indicate that the use of ASTM D7913 [1] to establish a required bond strength for the FRP bars requires further discussion in the research community. Additional tests were performed on concrete slabs reinforced with GFRP bar, serviceability limit states need further discussion to address the crack opening and deflection seen in the slabs reinforced with GFRP."],"dc:format":["application/pdf","p.62","49.41 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1689632006439284"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Engineering","GFRP","Pull-Out","Reinforced Concrete","ASTM D7913"],"dc:title":["The Effect of Surface Coating and Free End Condition on The Bond Behavior of GFRP Bars Embedded in Concrete"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:58:57Z"}