{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1705085611465787"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1705085611465787","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design of a Precision, Adjustable Current Source for Use In an MRI-Based Robotic Catheter System","abstract":"Heart catheter ablation surgeries often employ X-ray fluoroscopy to image the position of the catheter during the procedure. Magnetic Resonance Imaging (MRI) can be used to image the catheter position in real-time without exposing a patient to ionizing radiation while providing excellent soft tissue contrast. The MRI’s static magnetic field can be used in conjunction with current-carrying coils placed on a catheter to steer the catheter through a patient robotically. This thesis sees the development of a new system to precisely and accurately source current to these catheter coils in a way that ensures protection from the MRI’s harsh environment. The designed current driver boards with a switching topology allow for a significantly downsized system when compared to the older linear system. Relevant tests were performed on these boards to ensure their functionality and compliance with the MRI – including linearity, thermal drift, and filter performance.","abstract_html":"Heart catheter ablation surgeries often employ X-ray fluoroscopy to image the position of the catheter during the procedure. Magnetic Resonance Imaging (MRI) can be used to image the catheter position in real-time without exposing a patient to ionizing radiation while providing excellent soft tissue contrast. The MRI’s static magnetic field can be used in conjunction with current-carrying coils placed on a catheter to steer the catheter through a patient robotically. This thesis sees the development of a new system to precisely and accurately source current to these catheter coils in a way that ensures protection from the MRI’s harsh environment. The designed current driver boards with a switching topology allow for a significantly downsized system when compared to the older linear system. Relevant tests were performed on these boards to ensure their functionality and compliance with the MRI – including linearity, thermal drift, and filter performance.","abstract_has_math":false,"creators":["Mousa, Cole M."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Cavusoglu, M. Cenk"],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-27T04:59:10Z","subjects":["Electrical Engineering","MRI","EMC","precision electronics","current source","RF","medical robotics","switching amplifier"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1705085611465787","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1705085611465787","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1705085611465787","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1705085611465787","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cavusoglu, M. Cenk"]},{"key":"dc:creator","label":"Author","values":["Mousa, Cole M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","MRI","EMC","precision electronics","current source","RF","medical robotics","switching amplifier"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1705085611465787"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Heart catheter ablation surgeries often employ X-ray fluoroscopy to image the position of the catheter during the procedure. Magnetic Resonance Imaging (MRI) can be used to image the catheter position in real-time without exposing a patient to ionizing radiation while providing excellent soft tissue contrast. The MRI’s static magnetic field can be used in conjunction with current-carrying coils placed on a catheter to steer the catheter through a patient robotically. This thesis sees the development of a new system to precisely and accurately source current to these catheter coils in a way that ensures protection from the MRI’s harsh environment. The designed current driver boards with a switching topology allow for a significantly downsized system when compared to the older linear system. Relevant tests were performed on these boards to ensure their functionality and compliance with the MRI – including linearity, thermal drift, and filter performance."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.106","2.39 MB"]},{"key":"dc:title","label":"Title","values":["Design of a Precision, Adjustable Current Source for Use In an MRI-Based Robotic Catheter System"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cavusoglu, M. Cenk"],"dc:creator":["Mousa, Cole M."],"dc:date":["2023"],"dc:description":["Heart catheter ablation surgeries often employ X-ray fluoroscopy to image the position of the catheter during the procedure. Magnetic Resonance Imaging (MRI) can be used to image the catheter position in real-time without exposing a patient to ionizing radiation while providing excellent soft tissue contrast. The MRI’s static magnetic field can be used in conjunction with current-carrying coils placed on a catheter to steer the catheter through a patient robotically. This thesis sees the development of a new system to precisely and accurately source current to these catheter coils in a way that ensures protection from the MRI’s harsh environment. The designed current driver boards with a switching topology allow for a significantly downsized system when compared to the older linear system. Relevant tests were performed on these boards to ensure their functionality and compliance with the MRI – including linearity, thermal drift, and filter performance."],"dc:format":["application/pdf","p.106","2.39 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1705085611465787"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","MRI","EMC","precision electronics","current source","RF","medical robotics","switching amplifier"],"dc:title":["Design of a Precision, Adjustable Current Source for Use In an MRI-Based Robotic Catheter System"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:59:10Z"}