{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1707223343503156"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1707223343503156","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System","abstract":"Atrial fibrillation, a prevalent heart condition, poses significant health risks. Traditional treatment involves cardiac ablation catheters guided by x-ray fluoroscopy, which provides limited two-dimensional heart images and subjects patients to substantial radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization and eliminates radiation exposure. The MRI’s magnetic field can be leveraged in order to control a robotic ablation catheter with small electromagnetic coils in the catheter tip. However, these coils may interact negatively with the MRI’s radio-frequency transmitter, causing potential overheating.Prior research led to the development of a compact catheter prototype, primarily to demonstrate its fundamental operational principles. Nevertheless, this prototype’s limited size renders it unsuitable for practical application within the human body. The aim of this thesis is to engineer a full-scale catheter, a task that presents considerable challenges due to the demanding conditions of the MRI environment and the occurrence of standing waves on uncoupled elongated wires. This prototype is designed to meet the kinematic workspace specifications identified in earlier studies, while also ensuring full compatibility with a human subject. The prototype maintains a low heat output and does not interfere with the MRI’s functionality.","abstract_html":"Atrial fibrillation, a prevalent heart condition, poses significant health risks. Traditional treatment involves cardiac ablation catheters guided by x-ray fluoroscopy, which provides limited two-dimensional heart images and subjects patients to substantial radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization and eliminates radiation exposure. The MRI’s magnetic field can be leveraged in order to control a robotic ablation catheter with small electromagnetic coils in the catheter tip. However, these coils may interact negatively with the MRI’s radio-frequency transmitter, causing potential overheating.Prior research led to the development of a compact catheter prototype, primarily to demonstrate its fundamental operational principles. Nevertheless, this prototype’s limited size renders it unsuitable for practical application within the human body. The aim of this thesis is to engineer a full-scale catheter, a task that presents considerable challenges due to the demanding conditions of the MRI environment and the occurrence of standing waves on uncoupled elongated wires. This prototype is designed to meet the kinematic workspace specifications identified in earlier studies, while also ensuring full compatibility with a human subject. The prototype maintains a low heat output and does not interfere with the MRI’s functionality.","abstract_has_math":false,"creators":["Foss, Gabriel Jordan"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Cavusoglu, M. Cenk"],"committee_members":[],"year":2024,"date_issued":"2024-05-24","date_published":"2024-05-24","updated_at":"2026-11-27T04:59:10Z","subjects":["Engineering","Electrical Engineering","Biomedical Engineering","Robotics","Medical Imaging","Medicine","Atrial Fibrillation","Cardiac Ablation Catheter","Magnetic Resonance Imaging","MRI Robot","Electromagnetic Compatibility","RF Heating","Thermal Safety","MRI Environment","MRI Compatibility","MR Conditional","Standing Waves","Magnetic Actuation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1707223343503156","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1707223343503156","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1707223343503156","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1707223343503156","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cavusoglu, M. Cenk"]},{"key":"dc:creator","label":"Author","values":["Foss, Gabriel Jordan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-05-24"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Electrical Engineering","Biomedical Engineering","Robotics","Medical Imaging","Medicine","Atrial Fibrillation","Cardiac Ablation Catheter","Magnetic Resonance Imaging","MRI Robot","Electromagnetic Compatibility","RF Heating","Thermal Safety","MRI Environment","MRI Compatibility","MR Conditional","Standing Waves","Magnetic Actuation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1707223343503156"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Atrial fibrillation, a prevalent heart condition, poses significant health risks. Traditional treatment involves cardiac ablation catheters guided by x-ray fluoroscopy, which provides limited two-dimensional heart images and subjects patients to substantial radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization and eliminates radiation exposure. The MRI’s magnetic field can be leveraged in order to control a robotic ablation catheter with small electromagnetic coils in the catheter tip. However, these coils may interact negatively with the MRI’s radio-frequency transmitter, causing potential overheating.Prior research led to the development of a compact catheter prototype, primarily to demonstrate its fundamental operational principles. Nevertheless, this prototype’s limited size renders it unsuitable for practical application within the human body. The aim of this thesis is to engineer a full-scale catheter, a task that presents considerable challenges due to the demanding conditions of the MRI environment and the occurrence of standing waves on uncoupled elongated wires. This prototype is designed to meet the kinematic workspace specifications identified in earlier studies, while also ensuring full compatibility with a human subject. The prototype maintains a low heat output and does not interfere with the MRI’s functionality."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.57","38.77 MB"]},{"key":"dc:title","label":"Title","values":["Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cavusoglu, M. Cenk"],"dc:creator":["Foss, Gabriel Jordan"],"dc:date":["2024-05-24"],"dc:description":["Atrial fibrillation, a prevalent heart condition, poses significant health risks. Traditional treatment involves cardiac ablation catheters guided by x-ray fluoroscopy, which provides limited two-dimensional heart images and subjects patients to substantial radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization and eliminates radiation exposure. The MRI’s magnetic field can be leveraged in order to control a robotic ablation catheter with small electromagnetic coils in the catheter tip. However, these coils may interact negatively with the MRI’s radio-frequency transmitter, causing potential overheating.Prior research led to the development of a compact catheter prototype, primarily to demonstrate its fundamental operational principles. Nevertheless, this prototype’s limited size renders it unsuitable for practical application within the human body. The aim of this thesis is to engineer a full-scale catheter, a task that presents considerable challenges due to the demanding conditions of the MRI environment and the occurrence of standing waves on uncoupled elongated wires. This prototype is designed to meet the kinematic workspace specifications identified in earlier studies, while also ensuring full compatibility with a human subject. The prototype maintains a low heat output and does not interfere with the MRI’s functionality."],"dc:format":["application/pdf","p.57","38.77 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1707223343503156"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Electrical Engineering","Biomedical Engineering","Robotics","Medical Imaging","Medicine","Atrial Fibrillation","Cardiac Ablation Catheter","Magnetic Resonance Imaging","MRI Robot","Electromagnetic Compatibility","RF Heating","Thermal Safety","MRI Environment","MRI Compatibility","MR Conditional","Standing Waves","Magnetic Actuation"],"dc:title":["Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:59:10Z"}