{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1708081573912911"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1708081573912911","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Disease Detection and Isolation Utilizing Magnetic Fields: Hemozoin, Magnetic Particles, Cells and Clusters","abstract":"The goal of this work is to investigate magnetic materials (MM) and the influence of magnetic field on different shapes and types of MM with innovative magnetic devices. Using magneto-optical detection devices, we examined the physical science of two MM systems: malarial hemozoin (a paramagnetic crystal) in rod-like form, and synthetic magnetic particles with iron oxide cores in spherical form. The second study focuses on capturing and imaging targeted cells using a newly developed CAPGLO device that combines magnetic and fluorescent mechanisms.Due to their magnetic properties, the crystalline hemozoin shows unique alternation in the presence of a magnetic field. Using a light beam, we were able to detect and verify the changes in the direction of the crystal by measuring the polarization-dependent optical absorption when the magnetic field is alternated between on and off. Our results show a factor of two increase in absorption as it grows with light polarization along the easy-axis crystallographic direction compared to polarization along the hard-axis (ax/az = σx/σz = 2), which shows a correlation between the basic physics and the chemical structure of the crystal.The characteristics of magnetophoresis – that is, motion under a gradient magnetic field of magnetic particles (MP) suspended in fluid – are analyzed. As the MP migrate from the center of the sample toward the magnets, we measure the changes in the photodiode detector voltage for the light beam over time. Our results show the effect of different concentrations and MP sizes. In addition, we notice a universal pattern that displays multiple phases that are correlated with the motion of fluid, the chain formation of MPs, and the complete separation of the MPs.Lastly, CAPGLO is an original magnetic detector designed to capture the composite made up of an MP binding to a cell. The cancer cell example has concentrations corresponding to biopsies. The composites are imaged using a fluorescence technique. The cell targeting, catching and imaging are demonstrated. The capture step is important for monitoring the molecular changes in cancer cells and how well a treatment is working. Its low-cost, user-friendly and specificity in capturing low concentration of target cells makes it vital for cancer detection in developing countries.","abstract_html":"The goal of this work is to investigate magnetic materials (MM) and the influence of magnetic field on different shapes and types of MM with innovative magnetic devices. Using magneto-optical detection devices, we examined the physical science of two MM systems: malarial hemozoin (a paramagnetic crystal) in rod-like form, and synthetic magnetic particles with iron oxide cores in spherical form. The second study focuses on capturing and imaging targeted cells using a newly developed CAPGLO device that combines magnetic and fluorescent mechanisms.Due to their magnetic properties, the crystalline hemozoin shows unique alternation in the presence of a magnetic field. Using a light beam, we were able to detect and verify the changes in the direction of the crystal by measuring the polarization-dependent optical absorption when the magnetic field is alternated between on and off. Our results show a factor of two increase in absorption as it grows with light polarization along the easy-axis crystallographic direction compared to polarization along the hard-axis (ax/az = σx/σz = 2), which shows a correlation between the basic physics and the chemical structure of the crystal.The characteristics of magnetophoresis – that is, motion under a gradient magnetic field of magnetic particles (MP) suspended in fluid – are analyzed. As the MP migrate from the center of the sample toward the magnets, we measure the changes in the photodiode detector voltage for the light beam over time. Our results show the effect of different concentrations and MP sizes. In addition, we notice a universal pattern that displays multiple phases that are correlated with the motion of fluid, the chain formation of MPs, and the complete separation of the MPs.Lastly, CAPGLO is an original magnetic detector designed to capture the composite made up of an MP binding to a cell. The cancer cell example has concentrations corresponding to biopsies. The composites are imaged using a fluorescence technique. The cell targeting, catching and imaging are demonstrated. The capture step is important for monitoring the molecular changes in cancer cells and how well a treatment is working. Its low-cost, user-friendly and specificity in capturing low concentration of target cells makes it vital for cancer detection in developing countries.","abstract_has_math":false,"creators":["Al Helo, Rose"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Brown, Robert"],"committee_members":[],"year":2024,"date_issued":"2024-05-24","date_published":"2024-05-24","updated_at":"2026-11-27T04:59:10Z","subjects":["Physics","Experiments","Magnetic Field","Magnetic Particles","Magnetic Material","Functionalized Magnetic Particles","Cell-Cell adhesion Molecular","Magnetized Cells","Hemozoin","CAPGLO","Magneto-optical detection device","Magnetophoresis","Capturing and imaging","Detection and isolation","Probing magnetic crystals"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1708081573912911","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1708081573912911","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1708081573912911","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1708081573912911","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Brown, Robert"]},{"key":"dc:creator","label":"Author","values":["Al Helo, Rose"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-05-24"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Experiments","Magnetic Field","Magnetic Particles","Magnetic Material","Functionalized Magnetic Particles","Cell-Cell adhesion Molecular","Magnetized Cells","Hemozoin","CAPGLO","Magneto-optical detection device","Magnetophoresis","Capturing and imaging","Detection and isolation","Probing magnetic crystals"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1708081573912911"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The goal of this work is to investigate magnetic materials (MM) and the influence of magnetic field on different shapes and types of MM with innovative magnetic devices. Using magneto-optical detection devices, we examined the physical science of two MM systems: malarial hemozoin (a paramagnetic crystal) in rod-like form, and synthetic magnetic particles with iron oxide cores in spherical form. The second study focuses on capturing and imaging targeted cells using a newly developed CAPGLO device that combines magnetic and fluorescent mechanisms.Due to their magnetic properties, the crystalline hemozoin shows unique alternation in the presence of a magnetic field. Using a light beam, we were able to detect and verify the changes in the direction of the crystal by measuring the polarization-dependent optical absorption when the magnetic field is alternated between on and off. Our results show a factor of two increase in absorption as it grows with light polarization along the easy-axis crystallographic direction compared to polarization along the hard-axis (ax/az = σx/σz = 2), which shows a correlation between the basic physics and the chemical structure of the crystal.The characteristics of magnetophoresis – that is, motion under a gradient magnetic field of magnetic particles (MP) suspended in fluid – are analyzed. As the MP migrate from the center of the sample toward the magnets, we measure the changes in the photodiode detector voltage for the light beam over time. Our results show the effect of different concentrations and MP sizes. In addition, we notice a universal pattern that displays multiple phases that are correlated with the motion of fluid, the chain formation of MPs, and the complete separation of the MPs.Lastly, CAPGLO is an original magnetic detector designed to capture the composite made up of an MP binding to a cell. The cancer cell example has concentrations corresponding to biopsies. The composites are imaged using a fluorescence technique. The cell targeting, catching and imaging are demonstrated. The capture step is important for monitoring the molecular changes in cancer cells and how well a treatment is working. Its low-cost, user-friendly and specificity in capturing low concentration of target cells makes it vital for cancer detection in developing countries."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.122","2.71 MB"]},{"key":"dc:title","label":"Title","values":["Disease Detection and Isolation Utilizing Magnetic Fields: Hemozoin, Magnetic Particles, Cells and Clusters"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Brown, Robert"],"dc:creator":["Al Helo, Rose"],"dc:date":["2024-05-24"],"dc:description":["The goal of this work is to investigate magnetic materials (MM) and the influence of magnetic field on different shapes and types of MM with innovative magnetic devices. Using magneto-optical detection devices, we examined the physical science of two MM systems: malarial hemozoin (a paramagnetic crystal) in rod-like form, and synthetic magnetic particles with iron oxide cores in spherical form. The second study focuses on capturing and imaging targeted cells using a newly developed CAPGLO device that combines magnetic and fluorescent mechanisms.Due to their magnetic properties, the crystalline hemozoin shows unique alternation in the presence of a magnetic field. Using a light beam, we were able to detect and verify the changes in the direction of the crystal by measuring the polarization-dependent optical absorption when the magnetic field is alternated between on and off. Our results show a factor of two increase in absorption as it grows with light polarization along the easy-axis crystallographic direction compared to polarization along the hard-axis (ax/az = σx/σz = 2), which shows a correlation between the basic physics and the chemical structure of the crystal.The characteristics of magnetophoresis – that is, motion under a gradient magnetic field of magnetic particles (MP) suspended in fluid – are analyzed. As the MP migrate from the center of the sample toward the magnets, we measure the changes in the photodiode detector voltage for the light beam over time. Our results show the effect of different concentrations and MP sizes. In addition, we notice a universal pattern that displays multiple phases that are correlated with the motion of fluid, the chain formation of MPs, and the complete separation of the MPs.Lastly, CAPGLO is an original magnetic detector designed to capture the composite made up of an MP binding to a cell. The cancer cell example has concentrations corresponding to biopsies. The composites are imaged using a fluorescence technique. The cell targeting, catching and imaging are demonstrated. The capture step is important for monitoring the molecular changes in cancer cells and how well a treatment is working. Its low-cost, user-friendly and specificity in capturing low concentration of target cells makes it vital for cancer detection in developing countries."],"dc:format":["application/pdf","p.122","2.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1708081573912911"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Experiments","Magnetic Field","Magnetic Particles","Magnetic Material","Functionalized Magnetic Particles","Cell-Cell adhesion Molecular","Magnetized Cells","Hemozoin","CAPGLO","Magneto-optical detection device","Magnetophoresis","Capturing and imaging","Detection and isolation","Probing magnetic crystals"],"dc:title":["Disease Detection and Isolation Utilizing Magnetic Fields: Hemozoin, Magnetic Particles, Cells and Clusters"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:59:10Z"}