{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case174360011834895"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case174360011834895","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Perceptual, Functional, and Psychosocial Impacts of a Wirelessly Connected Implanted Sensorimotor Interface for Bidirectional Upper Limb Neuroprostheses","abstract":"Individuals with upper limb loss are often dissatisfied with commercial prostheses due to factors such as unreliable control and lack of sensory feedback, contributing to reduced function and worsened psychosocial experiences. Implanted nerve stimulation and myoelectric recording systems offer promising solutions by providing sensation and more advanced prosthetic control. However, several challenges hinder translation of these technologies, including percutaneous lead maintenance, bulky external processors, a limited number of implanted electrode channels, and a narrow focus on either sensory feedback or myoelectric sensing, rather than both features. Additionally, the benefits of implanted bidirectional neuroprostheses over commercially available state-of-the-art (SOA) prostheses remain unevaluated. To create a more complete sensorimotor restoration system, our team developed a non-percutaneous, implanted somatosensory electrical neurostimulation and sensing (iSENS) system, featuring bidirectional stimulation and sensing, wireless communication, and an increased electrode channel count. The central hypothesis was that iSENS would enhance sensory perception, myoelectric control, psychosocial experiences, and function for upper limb prosthesis users.Initial feasibility testing in two individuals with upper limb loss confirmed iSENS long-term stability and validated bidirectional 3 degree-of-freedom (DOF) prosthetic control with sensory feedback. The iSENS system’s increased implanted channel count improved 4 DOF myoelectric controller performance, expanded sensory location coverage across the hand, and increased the number of distinct percept locations, enabling diverse sensory feedback. Beyond the laboratory environment, long-term home use of iSENS with a bidirectional prosthesis led to significant improvements in psychosocial outcomes, including social interaction and embodiment, compared to a clinically prescribed SOA prosthesis. Although the tendency to favor the sound arm over the prosthesis did not change, functional dexterity and activities of daily living performance improved, likely facilitated by the high DOF prosthetic control enabled by iSENS.This work validates iSENS as a fully implanted bidirectional neuroprosthetic system that enhances sensory perception and myoelectric control, thus providing meaningful psychosocial and functional benefits to prosthesis users. These findings represent significant progress toward clinical translation of implanted sensorimotor interfaces to overcome limitations of conventional prostheses and ultimately improve the lives of individuals with limb loss.","abstract_html":"Individuals with upper limb loss are often dissatisfied with commercial prostheses due to factors such as unreliable control and lack of sensory feedback, contributing to reduced function and worsened psychosocial experiences. Implanted nerve stimulation and myoelectric recording systems offer promising solutions by providing sensation and more advanced prosthetic control. However, several challenges hinder translation of these technologies, including percutaneous lead maintenance, bulky external processors, a limited number of implanted electrode channels, and a narrow focus on either sensory feedback or myoelectric sensing, rather than both features. Additionally, the benefits of implanted bidirectional neuroprostheses over commercially available state-of-the-art (SOA) prostheses remain unevaluated. To create a more complete sensorimotor restoration system, our team developed a non-percutaneous, implanted somatosensory electrical neurostimulation and sensing (iSENS) system, featuring bidirectional stimulation and sensing, wireless communication, and an increased electrode channel count. The central hypothesis was that iSENS would enhance sensory perception, myoelectric control, psychosocial experiences, and function for upper limb prosthesis users.Initial feasibility testing in two individuals with upper limb loss confirmed iSENS long-term stability and validated bidirectional 3 degree-of-freedom (DOF) prosthetic control with sensory feedback. The iSENS system’s increased implanted channel count improved 4 DOF myoelectric controller performance, expanded sensory location coverage across the hand, and increased the number of distinct percept locations, enabling diverse sensory feedback. Beyond the laboratory environment, long-term home use of iSENS with a bidirectional prosthesis led to significant improvements in psychosocial outcomes, including social interaction and embodiment, compared to a clinically prescribed SOA prosthesis. Although the tendency to favor the sound arm over the prosthesis did not change, functional dexterity and activities of daily living performance improved, likely facilitated by the high DOF prosthetic control enabled by iSENS.This work validates iSENS as a fully implanted bidirectional neuroprosthetic system that enhances sensory perception and myoelectric control, thus providing meaningful psychosocial and functional benefits to prosthesis users. These findings represent significant progress toward clinical translation of implanted sensorimotor interfaces to overcome limitations of conventional prostheses and ultimately improve the lives of individuals with limb loss.","abstract_has_math":false,"creators":["Cady, Sedona Rae"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Tyler, Dustin","Gustafson, Kenneth"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-05-08","date_published":"2025-05-08","updated_at":"2026-11-26T07:37:02Z","subjects":["Neurosciences","Biomedical Engineering","peripheral nerve stimulation","myoelectric control","limb loss","fully implanted devices","neuroprostheses"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case174360011834895","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case174360011834895","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase174360011834895","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase174360011834895","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tyler, Dustin","Gustafson, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Cady, Sedona Rae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-05-08"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neurosciences","Biomedical Engineering","peripheral nerve stimulation","myoelectric control","limb loss","fully implanted devices","neuroprostheses"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case174360011834895"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Individuals with upper limb loss are often dissatisfied with commercial prostheses due to factors such as unreliable control and lack of sensory feedback, contributing to reduced function and worsened psychosocial experiences. Implanted nerve stimulation and myoelectric recording systems offer promising solutions by providing sensation and more advanced prosthetic control. However, several challenges hinder translation of these technologies, including percutaneous lead maintenance, bulky external processors, a limited number of implanted electrode channels, and a narrow focus on either sensory feedback or myoelectric sensing, rather than both features. Additionally, the benefits of implanted bidirectional neuroprostheses over commercially available state-of-the-art (SOA) prostheses remain unevaluated. To create a more complete sensorimotor restoration system, our team developed a non-percutaneous, implanted somatosensory electrical neurostimulation and sensing (iSENS) system, featuring bidirectional stimulation and sensing, wireless communication, and an increased electrode channel count. The central hypothesis was that iSENS would enhance sensory perception, myoelectric control, psychosocial experiences, and function for upper limb prosthesis users.Initial feasibility testing in two individuals with upper limb loss confirmed iSENS long-term stability and validated bidirectional 3 degree-of-freedom (DOF) prosthetic control with sensory feedback. The iSENS system’s increased implanted channel count improved 4 DOF myoelectric controller performance, expanded sensory location coverage across the hand, and increased the number of distinct percept locations, enabling diverse sensory feedback. Beyond the laboratory environment, long-term home use of iSENS with a bidirectional prosthesis led to significant improvements in psychosocial outcomes, including social interaction and embodiment, compared to a clinically prescribed SOA prosthesis. Although the tendency to favor the sound arm over the prosthesis did not change, functional dexterity and activities of daily living performance improved, likely facilitated by the high DOF prosthetic control enabled by iSENS.This work validates iSENS as a fully implanted bidirectional neuroprosthetic system that enhances sensory perception and myoelectric control, thus providing meaningful psychosocial and functional benefits to prosthesis users. These findings represent significant progress toward clinical translation of implanted sensorimotor interfaces to overcome limitations of conventional prostheses and ultimately improve the lives of individuals with limb loss."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.313","44.33 MB"]},{"key":"dc:title","label":"Title","values":["Perceptual, Functional, and Psychosocial Impacts of a Wirelessly Connected Implanted Sensorimotor Interface for Bidirectional Upper Limb Neuroprostheses"]}]}],"canonical_facts":{"dc:contributor":["Tyler, Dustin","Gustafson, Kenneth"],"dc:creator":["Cady, Sedona Rae"],"dc:date":["2025-05-08"],"dc:description":["Individuals with upper limb loss are often dissatisfied with commercial prostheses due to factors such as unreliable control and lack of sensory feedback, contributing to reduced function and worsened psychosocial experiences. Implanted nerve stimulation and myoelectric recording systems offer promising solutions by providing sensation and more advanced prosthetic control. However, several challenges hinder translation of these technologies, including percutaneous lead maintenance, bulky external processors, a limited number of implanted electrode channels, and a narrow focus on either sensory feedback or myoelectric sensing, rather than both features. Additionally, the benefits of implanted bidirectional neuroprostheses over commercially available state-of-the-art (SOA) prostheses remain unevaluated. To create a more complete sensorimotor restoration system, our team developed a non-percutaneous, implanted somatosensory electrical neurostimulation and sensing (iSENS) system, featuring bidirectional stimulation and sensing, wireless communication, and an increased electrode channel count. The central hypothesis was that iSENS would enhance sensory perception, myoelectric control, psychosocial experiences, and function for upper limb prosthesis users.Initial feasibility testing in two individuals with upper limb loss confirmed iSENS long-term stability and validated bidirectional 3 degree-of-freedom (DOF) prosthetic control with sensory feedback. The iSENS system’s increased implanted channel count improved 4 DOF myoelectric controller performance, expanded sensory location coverage across the hand, and increased the number of distinct percept locations, enabling diverse sensory feedback. Beyond the laboratory environment, long-term home use of iSENS with a bidirectional prosthesis led to significant improvements in psychosocial outcomes, including social interaction and embodiment, compared to a clinically prescribed SOA prosthesis. Although the tendency to favor the sound arm over the prosthesis did not change, functional dexterity and activities of daily living performance improved, likely facilitated by the high DOF prosthetic control enabled by iSENS.This work validates iSENS as a fully implanted bidirectional neuroprosthetic system that enhances sensory perception and myoelectric control, thus providing meaningful psychosocial and functional benefits to prosthesis users. These findings represent significant progress toward clinical translation of implanted sensorimotor interfaces to overcome limitations of conventional prostheses and ultimately improve the lives of individuals with limb loss."],"dc:format":["application/pdf","p.313","44.33 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case174360011834895"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Neurosciences","Biomedical Engineering","peripheral nerve stimulation","myoelectric control","limb loss","fully implanted devices","neuroprostheses"],"dc:title":["Perceptual, Functional, and Psychosocial Impacts of a Wirelessly Connected Implanted Sensorimotor Interface for Bidirectional Upper Limb Neuroprostheses"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T07:37:02Z"}