{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case175370493199533"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case175370493199533","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"TOWARDS ENHANCING SENSING IN SUPERVISORY CONTROL FOR MINIMALLY INVASIVE SURGERY","abstract":"This thesis presents a novel system for accurate 3D reconstruction in robot assisted minimally invasive surgery (MIS), addressing the limitations of current stereo vision approaches in platforms like the da Vinci surgical system. The research focuses on developing and integrating depth from motion, structured light projection, and hand-eye calibration techniques to enhance the accuracy and robustness of 3D mapping in challenging surgical environments. A method for determining 3D coordinates of fiducials using camera motion is developed and validated using synthetic data, achieving high accuracy with an RMS error of 10−7. This method is then applied to physical data, considering real-world factors like camera intrinsics and potential errors from the physical setup. The thesis further explores hand-eye calibration methods to establish the transform between the robot base frame and the camera frame, enabling accurate robot interaction with the surgical scene. Structured light projection is integrated to enhance 3D reconstruction and object recognition, particularly for complex and deformable surfaces. Additionally, the thesis investigates motor current-based force estimation to provide crucial tactile feedback. The system is validated through experiments on various objects and a synthetic tissue phantom, demonstrating its capability to accurately identify and interact with objects in a biocompatible manner. This research contributes to advancing the precision and capabilities of medical robots, paving the way for improved surgical outcomes and increased automation potential in MI.","abstract_html":"This thesis presents a novel system for accurate 3D reconstruction in robot assisted minimally invasive surgery (MIS), addressing the limitations of current stereo vision approaches in platforms like the da Vinci surgical system. The research focuses on developing and integrating depth from motion, structured light projection, and hand-eye calibration techniques to enhance the accuracy and robustness of 3D mapping in challenging surgical environments. A method for determining 3D coordinates of fiducials using camera motion is developed and validated using synthetic data, achieving high accuracy with an RMS error of 10−7. This method is then applied to physical data, considering real-world factors like camera intrinsics and potential errors from the physical setup. The thesis further explores hand-eye calibration methods to establish the transform between the robot base frame and the camera frame, enabling accurate robot interaction with the surgical scene. Structured light projection is integrated to enhance 3D reconstruction and object recognition, particularly for complex and deformable surfaces. Additionally, the thesis investigates motor current-based force estimation to provide crucial tactile feedback. The system is validated through experiments on various objects and a synthetic tissue phantom, demonstrating its capability to accurately identify and interact with objects in a biocompatible manner. This research contributes to advancing the precision and capabilities of medical robots, paving the way for improved surgical outcomes and increased automation potential in MI.","abstract_has_math":false,"creators":["Nahari, Ammar Jamal Abdulmalik"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Newman, Wyatt"],"committee_members":[],"year":2025,"date_issued":"2025-08-22","date_published":"2025-08-22","updated_at":"2026-11-27T05:01:52Z","subjects":["Automotive Engineering","Electrical Engineering","Mechanical Engineering","Computer Engineering","Minimally Invasive Surgery","Robotic Surgery","3D Reconstruction","Depth from Motion","Structured Light","Hand-Eye Calibration","Force Estimation","Tactile Feedback","Surgical Automation","Robot-Assisted Surgery","Medical Robotics","Spatial Mapping","Image-Guided Surgery"],"languages":["English"],"rights":["restricted--full text unavailable until 2027-08-15","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case175370493199533","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case175370493199533","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase175370493199533","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase175370493199533","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Newman, Wyatt"]},{"key":"dc:creator","label":"Author","values":["Nahari, Ammar Jamal Abdulmalik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-08-22"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Automotive Engineering","Electrical Engineering","Mechanical Engineering","Computer Engineering","Minimally Invasive Surgery","Robotic Surgery","3D Reconstruction","Depth from Motion","Structured Light","Hand-Eye Calibration","Force Estimation","Tactile Feedback","Surgical Automation","Robot-Assisted Surgery","Medical Robotics","Spatial Mapping","Image-Guided Surgery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text unavailable until 2027-08-15","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case175370493199533"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis presents a novel system for accurate 3D reconstruction in robot assisted minimally invasive surgery (MIS), addressing the limitations of current stereo vision approaches in platforms like the da Vinci surgical system. The research focuses on developing and integrating depth from motion, structured light projection, and hand-eye calibration techniques to enhance the accuracy and robustness of 3D mapping in challenging surgical environments. A method for determining 3D coordinates of fiducials using camera motion is developed and validated using synthetic data, achieving high accuracy with an RMS error of 10−7. This method is then applied to physical data, considering real-world factors like camera intrinsics and potential errors from the physical setup. The thesis further explores hand-eye calibration methods to establish the transform between the robot base frame and the camera frame, enabling accurate robot interaction with the surgical scene. Structured light projection is integrated to enhance 3D reconstruction and object recognition, particularly for complex and deformable surfaces. Additionally, the thesis investigates motor current-based force estimation to provide crucial tactile feedback. The system is validated through experiments on various objects and a synthetic tissue phantom, demonstrating its capability to accurately identify and interact with objects in a biocompatible manner. This research contributes to advancing the precision and capabilities of medical robots, paving the way for improved surgical outcomes and increased automation potential in MI."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.266","2.88 MB"]},{"key":"dc:title","label":"Title","values":["TOWARDS ENHANCING SENSING IN SUPERVISORY CONTROL FOR MINIMALLY INVASIVE SURGERY"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Newman, Wyatt"],"dc:creator":["Nahari, Ammar Jamal Abdulmalik"],"dc:date":["2025-08-22"],"dc:description":["This thesis presents a novel system for accurate 3D reconstruction in robot assisted minimally invasive surgery (MIS), addressing the limitations of current stereo vision approaches in platforms like the da Vinci surgical system. The research focuses on developing and integrating depth from motion, structured light projection, and hand-eye calibration techniques to enhance the accuracy and robustness of 3D mapping in challenging surgical environments. A method for determining 3D coordinates of fiducials using camera motion is developed and validated using synthetic data, achieving high accuracy with an RMS error of 10−7. This method is then applied to physical data, considering real-world factors like camera intrinsics and potential errors from the physical setup. The thesis further explores hand-eye calibration methods to establish the transform between the robot base frame and the camera frame, enabling accurate robot interaction with the surgical scene. Structured light projection is integrated to enhance 3D reconstruction and object recognition, particularly for complex and deformable surfaces. Additionally, the thesis investigates motor current-based force estimation to provide crucial tactile feedback. The system is validated through experiments on various objects and a synthetic tissue phantom, demonstrating its capability to accurately identify and interact with objects in a biocompatible manner. This research contributes to advancing the precision and capabilities of medical robots, paving the way for improved surgical outcomes and increased automation potential in MI."],"dc:format":["application/pdf","p.266","2.88 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case175370493199533"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["restricted--full text unavailable until 2027-08-15","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Automotive Engineering","Electrical Engineering","Mechanical Engineering","Computer Engineering","Minimally Invasive Surgery","Robotic Surgery","3D Reconstruction","Depth from Motion","Structured Light","Hand-Eye Calibration","Force Estimation","Tactile Feedback","Surgical Automation","Robot-Assisted Surgery","Medical Robotics","Spatial Mapping","Image-Guided Surgery"],"dc:title":["TOWARDS ENHANCING SENSING IN SUPERVISORY CONTROL FOR MINIMALLY INVASIVE SURGERY"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:01:52Z"}