{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1764796877336444"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1764796877336444","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Force Sensing Telesurgical Tool With Shaft Integration of Commercial Force Sensor and Learning-Based Internal Cable Force Compensation","abstract":"Robot-assisted minimally invasive surgery (RAMIS) applies teleoperated robotic systems to provide surgeons with enhanced capabilities for minimally invasive surgery. Force sensing integrated into telesurgical tools supports applications of haptic feedback, as well as future research into force-informed autonomous systems. This motivates the need for accessible approaches to integrate force sensing into existing instruments. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes simplicity, reproducibility, and accessibility for research applications. A data-driven modeling framework is developed to compute applied forces at the end-effector, compensating for internal disturbances arising from actuation. This integrated sensing and modeling approach supports future studies on haptic feedback and force-informed autonomy in RAMIS, offering a versatile platform for advancing the development and evaluation of intelligent surgical systems.","abstract_html":"Robot-assisted minimally invasive surgery (RAMIS) applies teleoperated robotic systems to provide surgeons with enhanced capabilities for minimally invasive surgery. Force sensing integrated into telesurgical tools supports applications of haptic feedback, as well as future research into force-informed autonomous systems. This motivates the need for accessible approaches to integrate force sensing into existing instruments. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes simplicity, reproducibility, and accessibility for research applications. A data-driven modeling framework is developed to compute applied forces at the end-effector, compensating for internal disturbances arising from actuation. This integrated sensing and modeling approach supports future studies on haptic feedback and force-informed autonomy in RAMIS, offering a versatile platform for advancing the development and evaluation of intelligent surgical systems.","abstract_has_math":false,"creators":["Boone, Grant Joseph"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Chua, Zongue","Taylor, Brian","Wang, Peng"],"committee_members":[],"year":2026,"date_issued":"2026-01-27","date_published":"2026-01-27","updated_at":"2026-11-27T05:02:56Z","subjects":["Engineering","Mechanical Engineering","Technology","Robotics","Biomedical Engineering","Artificial Intelligence","Robot-assisted minimally invasive surgery, telesurgery, surgical robotics, surgical instruments, EndoWrist, dVRK, haptic feedback, force-informed autonomy, data-driven modeling, autonomous surgical systems, force and tactile sensing"],"languages":["English"],"rights":["restricted--full text unavailable until 2027-01-16","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1764796877336444","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1764796877336444","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1764796877336444","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1764796877336444","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Chua, Zongue","Taylor, Brian","Wang, Peng"]},{"key":"dc:creator","label":"Author","values":["Boone, Grant Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-01-27"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering","Technology","Robotics","Biomedical Engineering","Artificial Intelligence","Robot-assisted minimally invasive surgery, telesurgery, surgical robotics, surgical instruments, EndoWrist, dVRK, haptic feedback, force-informed autonomy, data-driven modeling, autonomous surgical systems, force and tactile sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text unavailable until 2027-01-16","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1764796877336444"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Robot-assisted minimally invasive surgery (RAMIS) applies teleoperated robotic systems to provide surgeons with enhanced capabilities for minimally invasive surgery. Force sensing integrated into telesurgical tools supports applications of haptic feedback, as well as future research into force-informed autonomous systems. This motivates the need for accessible approaches to integrate force sensing into existing instruments. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes simplicity, reproducibility, and accessibility for research applications. A data-driven modeling framework is developed to compute applied forces at the end-effector, compensating for internal disturbances arising from actuation. This integrated sensing and modeling approach supports future studies on haptic feedback and force-informed autonomy in RAMIS, offering a versatile platform for advancing the development and evaluation of intelligent surgical systems."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.81","9.81 MB"]},{"key":"dc:title","label":"Title","values":["Force Sensing Telesurgical Tool With Shaft Integration of Commercial Force Sensor and Learning-Based Internal Cable Force Compensation"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Chua, Zongue","Taylor, Brian","Wang, Peng"],"dc:creator":["Boone, Grant Joseph"],"dc:date":["2026-01-27"],"dc:description":["Robot-assisted minimally invasive surgery (RAMIS) applies teleoperated robotic systems to provide surgeons with enhanced capabilities for minimally invasive surgery. Force sensing integrated into telesurgical tools supports applications of haptic feedback, as well as future research into force-informed autonomous systems. This motivates the need for accessible approaches to integrate force sensing into existing instruments. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes simplicity, reproducibility, and accessibility for research applications. A data-driven modeling framework is developed to compute applied forces at the end-effector, compensating for internal disturbances arising from actuation. This integrated sensing and modeling approach supports future studies on haptic feedback and force-informed autonomy in RAMIS, offering a versatile platform for advancing the development and evaluation of intelligent surgical systems."],"dc:format":["application/pdf","p.81","9.81 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1764796877336444"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["restricted--full text unavailable until 2027-01-16","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Engineering","Mechanical Engineering","Technology","Robotics","Biomedical Engineering","Artificial Intelligence","Robot-assisted minimally invasive surgery, telesurgery, surgical robotics, surgical instruments, EndoWrist, dVRK, haptic feedback, force-informed autonomy, data-driven modeling, autonomous surgical systems, force and tactile sensing"],"dc:title":["Force Sensing Telesurgical Tool With Shaft Integration of Commercial Force Sensor and Learning-Based Internal Cable Force Compensation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:02:56Z"}