{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1769776205651694"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1769776205651694","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Impact of Individual Industrial Contaminants on the Electrodeposition of Copper onto Stainless Steel Substrates","abstract":"This study investigated the impact of industrial ionic contaminants of Sodium (Na<sup>+</sup>), Calcium (Ca<sup>2+</sup>), and Chloride (Cl<sup>-</sup>) on the quality of copper coatings deposited onto stainless steel substrates. Experiments were conducted under galvanostatic conditions in a Hull cell using plating solutions that contained three different levels of ionic contaminants. The Hull Cell geometry enabled the exploration of the full range of current densities on a single substrate. Constant electrolyte conditions were maintained aside from contaminant level. The quality of the coatings was analyzed via digital microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). At all current densities, Na<sup>+</sup> contamination had no significant effect on copper adherence or deposited structure but caused slight discoloration. It is hypothesized that the discoloration is due to preferential oxidation of copper in the presence of Na<sup>+</sup>. At all current densities, Ca<sup>2+</sup> contamination had no significant effect on copper adherence or deposited structure. The findings indicate that Cl<sup>-</sup> contaminants caused loosely adhered copper dendrites to form at high current densities. It is hypothesized that adsorbed Cl<sup>-</sup> ions change the solid-liquid interface to favor dendritic growth over planar growth. At lower current densities, Cl<sup>-</sup> continues to favor planar growth, as there is no significant effect on deposited shape or copper adherence.","abstract_html":"This study investigated the impact of industrial ionic contaminants of Sodium (Na&lt;sup&gt;+&lt;/sup&gt;), Calcium (Ca&lt;sup&gt;2+&lt;/sup&gt;), and Chloride (Cl&lt;sup&gt;-&lt;/sup&gt;) on the quality of copper coatings deposited onto stainless steel substrates. Experiments were conducted under galvanostatic conditions in a Hull cell using plating solutions that contained three different levels of ionic contaminants. The Hull Cell geometry enabled the exploration of the full range of current densities on a single substrate. Constant electrolyte conditions were maintained aside from contaminant level. The quality of the coatings was analyzed via digital microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). At all current densities, Na&lt;sup&gt;+&lt;/sup&gt; contamination had no significant effect on copper adherence or deposited structure but caused slight discoloration. It is hypothesized that the discoloration is due to preferential oxidation of copper in the presence of Na&lt;sup&gt;+&lt;/sup&gt;. At all current densities, Ca&lt;sup&gt;2+&lt;/sup&gt; contamination had no significant effect on copper adherence or deposited structure. The findings indicate that Cl&lt;sup&gt;-&lt;/sup&gt; contaminants caused loosely adhered copper dendrites to form at high current densities. It is hypothesized that adsorbed Cl&lt;sup&gt;-&lt;/sup&gt; ions change the solid-liquid interface to favor dendritic growth over planar growth. At lower current densities, Cl&lt;sup&gt;-&lt;/sup&gt; continues to favor planar growth, as there is no significant effect on deposited shape or copper adherence.","abstract_has_math":false,"creators":["Farah, Stephen Samir"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Carter, Jennifer"],"committee_members":[],"year":2026,"date_issued":"2026-05-22","date_published":"2026-05-22","updated_at":"2026-11-27T05:03:00Z","subjects":["Materials Science","Copper Electrodeposition","Copper Plating"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1769776205651694","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1769776205651694","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1769776205651694","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1769776205651694","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Carter, Jennifer"]},{"key":"dc:creator","label":"Author","values":["Farah, Stephen Samir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-05-22"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science","Copper Electrodeposition","Copper Plating"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1769776205651694"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study investigated the impact of industrial ionic contaminants of Sodium (Na<sup>+</sup>), Calcium (Ca<sup>2+</sup>), and Chloride (Cl<sup>-</sup>) on the quality of copper coatings deposited onto stainless steel substrates. Experiments were conducted under galvanostatic conditions in a Hull cell using plating solutions that contained three different levels of ionic contaminants. The Hull Cell geometry enabled the exploration of the full range of current densities on a single substrate. Constant electrolyte conditions were maintained aside from contaminant level. The quality of the coatings was analyzed via digital microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). At all current densities, Na<sup>+</sup> contamination had no significant effect on copper adherence or deposited structure but caused slight discoloration. It is hypothesized that the discoloration is due to preferential oxidation of copper in the presence of Na<sup>+</sup>. At all current densities, Ca<sup>2+</sup> contamination had no significant effect on copper adherence or deposited structure. The findings indicate that Cl<sup>-</sup> contaminants caused loosely adhered copper dendrites to form at high current densities. It is hypothesized that adsorbed Cl<sup>-</sup> ions change the solid-liquid interface to favor dendritic growth over planar growth. At lower current densities, Cl<sup>-</sup> continues to favor planar growth, as there is no significant effect on deposited shape or copper adherence."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","4.15 MB"]},{"key":"dc:title","label":"Title","values":["The Impact of Individual Industrial Contaminants on the Electrodeposition of Copper onto Stainless Steel Substrates"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Carter, Jennifer"],"dc:creator":["Farah, Stephen Samir"],"dc:date":["2026-05-22"],"dc:description":["This study investigated the impact of industrial ionic contaminants of Sodium (Na<sup>+</sup>), Calcium (Ca<sup>2+</sup>), and Chloride (Cl<sup>-</sup>) on the quality of copper coatings deposited onto stainless steel substrates. Experiments were conducted under galvanostatic conditions in a Hull cell using plating solutions that contained three different levels of ionic contaminants. The Hull Cell geometry enabled the exploration of the full range of current densities on a single substrate. Constant electrolyte conditions were maintained aside from contaminant level. The quality of the coatings was analyzed via digital microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). At all current densities, Na<sup>+</sup> contamination had no significant effect on copper adherence or deposited structure but caused slight discoloration. It is hypothesized that the discoloration is due to preferential oxidation of copper in the presence of Na<sup>+</sup>. At all current densities, Ca<sup>2+</sup> contamination had no significant effect on copper adherence or deposited structure. The findings indicate that Cl<sup>-</sup> contaminants caused loosely adhered copper dendrites to form at high current densities. It is hypothesized that adsorbed Cl<sup>-</sup> ions change the solid-liquid interface to favor dendritic growth over planar growth. At lower current densities, Cl<sup>-</sup> continues to favor planar growth, as there is no significant effect on deposited shape or copper adherence."],"dc:format":["application/pdf","4.15 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1769776205651694"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Materials Science","Copper Electrodeposition","Copper Plating"],"dc:title":["The Impact of Individual Industrial Contaminants on the Electrodeposition of Copper onto Stainless Steel Substrates"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:03:00Z"}