{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1779219548769436"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1779219548769436","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Numerical Simulation of Thermal Runaway Propagation Between Lithium-Ion Battery Cells with Detailed Heat Transfer and Gas Hazard Analysis","abstract":"Numerical modeling has played a critical role in understanding and mitigating thermal runaway propagation (TRP) of lithium-ion batteries (LIBs). However, the high computational cost of simulating this multi-physics process limits scalability. To help address this, a numerical model with detailed Computational Fluid Dynamics (CFD) and a semi-empirical solid battery model is developed based on thermal abuse tests of 18650 cylindrical cells. Experimentally obtained mass flow rate, compositions of vent gas, and pseudo-properties of the cell are incorporated as model inputs. This removes the need to simulate internal electrochemical reactions during thermal runaway, enabling a more general and cost-effective model.The model is first used to simulate 1×2 cell configuration with different spacings (s = 0–4 mm). The results of 0 and 2 mm spacing cases are successfully validated against experimental data. Temperature profiles, cell surface heat fluxes, and heat transfer mechanisms are compared between different cases. The results show that the dominant heat transfer mode varies with different stages of the event. For s > 0, heat transfer increases as the spacing decreases. However, radiation and convection alone are insufficient to trigger TRP. Only when s=0, cell-to-cell conduction is enabled and TRP occurs, consistent with experimental observations. A simplified thermal model is also developed to further understand the influence of spacing on convection and radiation.The model is then scaled up to a 1×3 configuration to investigate species transport and gas hazards during TRP. Predicted cell temperature, mass loss, and gas concentrations are compared with experimental data. The analysis indicates that the vent gas species peak during venting. The combustible gases are largely consumed during thermal runaway. Flammable regions are evaluated using Le Chatelier’s formula and remain limited in size during venting, with temperatures insufficient to support ignition. Toxic regions, assessed using immediately dangerous to life or health (IDLH) thresholds, develop over time and finally occupy a significant portion of the chamber.The numerical model developed in this study, with the potential to scale up and simulate more complex LIB TRP processes, can provide insights to inform design guidelines and support the development of safer LIB systems.","abstract_html":"Numerical modeling has played a critical role in understanding and mitigating thermal runaway propagation (TRP) of lithium-ion batteries (LIBs). However, the high computational cost of simulating this multi-physics process limits scalability. To help address this, a numerical model with detailed Computational Fluid Dynamics (CFD) and a semi-empirical solid battery model is developed based on thermal abuse tests of 18650 cylindrical cells. Experimentally obtained mass flow rate, compositions of vent gas, and pseudo-properties of the cell are incorporated as model inputs. This removes the need to simulate internal electrochemical reactions during thermal runaway, enabling a more general and cost-effective model.The model is first used to simulate 1×2 cell configuration with different spacings (s = 0–4 mm). The results of 0 and 2 mm spacing cases are successfully validated against experimental data. Temperature profiles, cell surface heat fluxes, and heat transfer mechanisms are compared between different cases. The results show that the dominant heat transfer mode varies with different stages of the event. For s &gt; 0, heat transfer increases as the spacing decreases. However, radiation and convection alone are insufficient to trigger TRP. Only when s=0, cell-to-cell conduction is enabled and TRP occurs, consistent with experimental observations. A simplified thermal model is also developed to further understand the influence of spacing on convection and radiation.The model is then scaled up to a 1×3 configuration to investigate species transport and gas hazards during TRP. Predicted cell temperature, mass loss, and gas concentrations are compared with experimental data. The analysis indicates that the vent gas species peak during venting. The combustible gases are largely consumed during thermal runaway. Flammable regions are evaluated using Le Chatelier’s formula and remain limited in size during venting, with temperatures insufficient to support ignition. Toxic regions, assessed using immediately dangerous to life or health (IDLH) thresholds, develop over time and finally occupy a significant portion of the chamber.The numerical model developed in this study, with the potential to scale up and simulate more complex LIB TRP processes, can provide insights to inform design guidelines and support the development of safer LIB systems.","abstract_has_math":false,"creators":["Wang, Boyu"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Liao, Ya-Ting"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08-14","date_published":"2026-08-14","updated_at":"2026-11-27T05:03:12Z","subjects":["Mechanical Engineering","Lithium-ion batteries","Thermal runaway propagation","Spacing between LIB cells","Numerical simulation","Heat transfer analysis","Gas hazard analysis"],"languages":["English"],"rights":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1779219548769436","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1779219548769436","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1779219548769436","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1779219548769436","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Liao, Ya-Ting"]},{"key":"dc:creator","label":"Author","values":["Wang, Boyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08-14"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Lithium-ion batteries","Thermal runaway propagation","Spacing between LIB cells","Numerical simulation","Heat transfer analysis","Gas hazard analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1779219548769436"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Numerical modeling has played a critical role in understanding and mitigating thermal runaway propagation (TRP) of lithium-ion batteries (LIBs). However, the high computational cost of simulating this multi-physics process limits scalability. To help address this, a numerical model with detailed Computational Fluid Dynamics (CFD) and a semi-empirical solid battery model is developed based on thermal abuse tests of 18650 cylindrical cells. Experimentally obtained mass flow rate, compositions of vent gas, and pseudo-properties of the cell are incorporated as model inputs. This removes the need to simulate internal electrochemical reactions during thermal runaway, enabling a more general and cost-effective model.The model is first used to simulate 1×2 cell configuration with different spacings (s = 0–4 mm). The results of 0 and 2 mm spacing cases are successfully validated against experimental data. Temperature profiles, cell surface heat fluxes, and heat transfer mechanisms are compared between different cases. The results show that the dominant heat transfer mode varies with different stages of the event. For s > 0, heat transfer increases as the spacing decreases. However, radiation and convection alone are insufficient to trigger TRP. Only when s=0, cell-to-cell conduction is enabled and TRP occurs, consistent with experimental observations. A simplified thermal model is also developed to further understand the influence of spacing on convection and radiation.The model is then scaled up to a 1×3 configuration to investigate species transport and gas hazards during TRP. Predicted cell temperature, mass loss, and gas concentrations are compared with experimental data. The analysis indicates that the vent gas species peak during venting. The combustible gases are largely consumed during thermal runaway. Flammable regions are evaluated using Le Chatelier’s formula and remain limited in size during venting, with temperatures insufficient to support ignition. Toxic regions, assessed using immediately dangerous to life or health (IDLH) thresholds, develop over time and finally occupy a significant portion of the chamber.The numerical model developed in this study, with the potential to scale up and simulate more complex LIB TRP processes, can provide insights to inform design guidelines and support the development of safer LIB systems."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.144","8.71 MB"]},{"key":"dc:title","label":"Title","values":["Numerical Simulation of Thermal Runaway Propagation Between Lithium-Ion Battery Cells with Detailed Heat Transfer and Gas Hazard Analysis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Liao, Ya-Ting"],"dc:creator":["Wang, Boyu"],"dc:date":["2026-08-14"],"dc:description":["Numerical modeling has played a critical role in understanding and mitigating thermal runaway propagation (TRP) of lithium-ion batteries (LIBs). However, the high computational cost of simulating this multi-physics process limits scalability. To help address this, a numerical model with detailed Computational Fluid Dynamics (CFD) and a semi-empirical solid battery model is developed based on thermal abuse tests of 18650 cylindrical cells. Experimentally obtained mass flow rate, compositions of vent gas, and pseudo-properties of the cell are incorporated as model inputs. This removes the need to simulate internal electrochemical reactions during thermal runaway, enabling a more general and cost-effective model.The model is first used to simulate 1×2 cell configuration with different spacings (s = 0–4 mm). The results of 0 and 2 mm spacing cases are successfully validated against experimental data. Temperature profiles, cell surface heat fluxes, and heat transfer mechanisms are compared between different cases. The results show that the dominant heat transfer mode varies with different stages of the event. For s > 0, heat transfer increases as the spacing decreases. However, radiation and convection alone are insufficient to trigger TRP. Only when s=0, cell-to-cell conduction is enabled and TRP occurs, consistent with experimental observations. A simplified thermal model is also developed to further understand the influence of spacing on convection and radiation.The model is then scaled up to a 1×3 configuration to investigate species transport and gas hazards during TRP. Predicted cell temperature, mass loss, and gas concentrations are compared with experimental data. The analysis indicates that the vent gas species peak during venting. The combustible gases are largely consumed during thermal runaway. Flammable regions are evaluated using Le Chatelier’s formula and remain limited in size during venting, with temperatures insufficient to support ignition. Toxic regions, assessed using immediately dangerous to life or health (IDLH) thresholds, develop over time and finally occupy a significant portion of the chamber.The numerical model developed in this study, with the potential to scale up and simulate more complex LIB TRP processes, can provide insights to inform design guidelines and support the development of safer LIB systems."],"dc:format":["application/pdf","p.144","8.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1779219548769436"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Lithium-ion batteries","Thermal runaway propagation","Spacing between LIB cells","Numerical simulation","Heat transfer analysis","Gas hazard analysis"],"dc:title":["Numerical Simulation of Thermal Runaway Propagation Between Lithium-Ion Battery Cells with Detailed Heat Transfer and Gas Hazard Analysis"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:03:12Z"}