{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1780337102854064"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1780337102854064","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Implantable Multimodal Hemodynamic Sensor Array","abstract":"Hemodynamics represent cardiovascular and physiological blood flow needs. Real-time hemodynamic monitoring could enable insights into overall cardiovascular health, enabling closed-loop interventions. Individual sensors only capture singular physical mechanisms underlying the arterial blood pressure waveform, preventing nuanced detection of cardiovascular state. By combining reliable sensors into a time-aligned multimodal sensor, physiological activity can be represented more robustly. This thesis proposes a multimodal sensor consisting of a thin-film microphone array, a flexible extravascular strain gauge, and a photoplethysmography sensor, to capture waveforms associated with blood sounds, vascular distention, and optical absorption respectively. Through benchtop characterization in progressing flow conditions, time-aligned waveforms were acquired, allowing for the extraction of key physiological parameters like heart rate and flow rate as well as more complex features associated with cross-waveform feature timing. With further analysis, key features and patterns in these waveforms can be extracted, compared, and aligned with an associated hemodynamic state. As advancements in machine learning progress, innovations in multimodal sensing can serve as the basis for future complex pattern recognition, allowing for the real-time identification of physiological state with higher precision.","abstract_html":"Hemodynamics represent cardiovascular and physiological blood flow needs. Real-time hemodynamic monitoring could enable insights into overall cardiovascular health, enabling closed-loop interventions. Individual sensors only capture singular physical mechanisms underlying the arterial blood pressure waveform, preventing nuanced detection of cardiovascular state. By combining reliable sensors into a time-aligned multimodal sensor, physiological activity can be represented more robustly. This thesis proposes a multimodal sensor consisting of a thin-film microphone array, a flexible extravascular strain gauge, and a photoplethysmography sensor, to capture waveforms associated with blood sounds, vascular distention, and optical absorption respectively. Through benchtop characterization in progressing flow conditions, time-aligned waveforms were acquired, allowing for the extraction of key physiological parameters like heart rate and flow rate as well as more complex features associated with cross-waveform feature timing. With further analysis, key features and patterns in these waveforms can be extracted, compared, and aligned with an associated hemodynamic state. As advancements in machine learning progress, innovations in multimodal sensing can serve as the basis for future complex pattern recognition, allowing for the real-time identification of physiological state with higher precision.","abstract_has_math":false,"creators":["Ramirez, Angel"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":["Majerus, Steve"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08-14","date_published":"2026-08-14","updated_at":"2026-11-26T08:16:46Z","subjects":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Engineering","Implantable sensor","multimodal sensor","hemodynamic monitoring","blood pressure sensor","blood flow sensor","extravascular","phonoangiography","flexible electronics","piezoresistive sensor","PVDF sensor","vascular access monitoring"],"languages":["English"],"rights":["restricted--full text unavailable until 2028-08-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1780337102854064","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1780337102854064","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1780337102854064","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1780337102854064","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Majerus, Steve"]},{"key":"dc:creator","label":"Author","values":["Ramirez, Angel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08-14"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Engineering","Implantable sensor","multimodal sensor","hemodynamic monitoring","blood pressure sensor","blood flow sensor","extravascular","phonoangiography","flexible electronics","piezoresistive sensor","PVDF sensor","vascular access monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text unavailable until 2028-08-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1780337102854064"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Hemodynamics represent cardiovascular and physiological blood flow needs. Real-time hemodynamic monitoring could enable insights into overall cardiovascular health, enabling closed-loop interventions. Individual sensors only capture singular physical mechanisms underlying the arterial blood pressure waveform, preventing nuanced detection of cardiovascular state. By combining reliable sensors into a time-aligned multimodal sensor, physiological activity can be represented more robustly. This thesis proposes a multimodal sensor consisting of a thin-film microphone array, a flexible extravascular strain gauge, and a photoplethysmography sensor, to capture waveforms associated with blood sounds, vascular distention, and optical absorption respectively. Through benchtop characterization in progressing flow conditions, time-aligned waveforms were acquired, allowing for the extraction of key physiological parameters like heart rate and flow rate as well as more complex features associated with cross-waveform feature timing. With further analysis, key features and patterns in these waveforms can be extracted, compared, and aligned with an associated hemodynamic state. As advancements in machine learning progress, innovations in multimodal sensing can serve as the basis for future complex pattern recognition, allowing for the real-time identification of physiological state with higher precision."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.92","4.77 MB"]},{"key":"dc:title","label":"Title","values":["Implantable Multimodal Hemodynamic Sensor Array"]}]}],"canonical_facts":{"dc:contributor":["Majerus, Steve"],"dc:creator":["Ramirez, Angel"],"dc:date":["2026-08-14"],"dc:description":["Hemodynamics represent cardiovascular and physiological blood flow needs. Real-time hemodynamic monitoring could enable insights into overall cardiovascular health, enabling closed-loop interventions. Individual sensors only capture singular physical mechanisms underlying the arterial blood pressure waveform, preventing nuanced detection of cardiovascular state. By combining reliable sensors into a time-aligned multimodal sensor, physiological activity can be represented more robustly. This thesis proposes a multimodal sensor consisting of a thin-film microphone array, a flexible extravascular strain gauge, and a photoplethysmography sensor, to capture waveforms associated with blood sounds, vascular distention, and optical absorption respectively. Through benchtop characterization in progressing flow conditions, time-aligned waveforms were acquired, allowing for the extraction of key physiological parameters like heart rate and flow rate as well as more complex features associated with cross-waveform feature timing. With further analysis, key features and patterns in these waveforms can be extracted, compared, and aligned with an associated hemodynamic state. As advancements in machine learning progress, innovations in multimodal sensing can serve as the basis for future complex pattern recognition, allowing for the real-time identification of physiological state with higher precision."],"dc:format":["application/pdf","p.92","4.77 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1780337102854064"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["restricted--full text unavailable until 2028-08-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Electrical Engineering","Engineering","Implantable sensor","multimodal sensor","hemodynamic monitoring","blood pressure sensor","blood flow sensor","extravascular","phonoangiography","flexible electronics","piezoresistive sensor","PVDF sensor","vascular access monitoring"],"dc:title":["Implantable Multimodal Hemodynamic Sensor Array"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T08:16:46Z"}