{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1780941601191802"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1780941601191802","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Localization Using Electrical Neural Stimulation (LENS) of Peripheral Nerves","abstract":"In this study, we introduce Localization using Electrical Neural Stimulation (LENS) toidentify the median nerve and the ulnar nerve, enabling subsequent application oftransient Selective Neural Inhibition via Photobiomodulation (tSNIP). Nerve localizationis necessary for tSNIP to avoid increased heating and for safer delivery. A computationalframework for neural stimulation of the wrist was developed to evaluate the effects oflateral electrode offset on nerve fiber activation for transverse tripolar, monopolar, andparallel tripolar electrode configurations. Sensitivity was defined as the reduction inactivated nerve fibers with increasing lateral offset within a clinically relevant stimulationwindow bounded by estimated pain and detection thresholds. The transverse tripoledemonstrated significantly greater sensitivity (p < 0.05) than monopolar and paralleltripolar configurations, indicating a rapid reduction in fiber activation with lateral offset.Human studies are needed to evaluate the clinical significance of LENS with a transversetripole.","abstract_html":"In this study, we introduce Localization using Electrical Neural Stimulation (LENS) toidentify the median nerve and the ulnar nerve, enabling subsequent application oftransient Selective Neural Inhibition via Photobiomodulation (tSNIP). Nerve localizationis necessary for tSNIP to avoid increased heating and for safer delivery. A computationalframework for neural stimulation of the wrist was developed to evaluate the effects oflateral electrode offset on nerve fiber activation for transverse tripolar, monopolar, andparallel tripolar electrode configurations. Sensitivity was defined as the reduction inactivated nerve fibers with increasing lateral offset within a clinically relevant stimulationwindow bounded by estimated pain and detection thresholds. The transverse tripoledemonstrated significantly greater sensitivity (p &lt; 0.05) than monopolar and paralleltripolar configurations, indicating a rapid reduction in fiber activation with lateral offset.Human studies are needed to evaluate the clinical significance of LENS with a transversetripole.","abstract_has_math":false,"creators":["Witt, Margaret Adelaide"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Moffitt, Michael","Jenkins, Michael"],"committee_chairs":["Durand, Dominique"],"committee_members":[],"year":2026,"date_issued":"2026-08-14","date_published":"2026-08-14","updated_at":"2026-11-27T05:03:12Z","subjects":["Biomedical Engineering","Transcutaneous Electrical Stimulation","Peripheral Nerves","transient Selective Neural Inhibition via Photobiomodulation","Transverse Tripole, Median Nerve, Ulnar Nerve, Neural Stimulation","McIntyre Richardson Grill (MRG) Model","Osteoarthritis","Electrode Offset","Paresthesia","Volume Conductor Model","Finite Element Model"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1780941601191802","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1780941601191802","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1780941601191802","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1780941601191802","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moffitt, Michael","Jenkins, Michael"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Witt, Margaret Adelaide"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08-14"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Transcutaneous Electrical Stimulation","Peripheral Nerves","transient Selective Neural Inhibition via Photobiomodulation","Transverse Tripole, Median Nerve, Ulnar Nerve, Neural Stimulation","McIntyre Richardson Grill (MRG) Model","Osteoarthritis","Electrode Offset","Paresthesia","Volume Conductor Model","Finite Element Model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1780941601191802"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this study, we introduce Localization using Electrical Neural Stimulation (LENS) toidentify the median nerve and the ulnar nerve, enabling subsequent application oftransient Selective Neural Inhibition via Photobiomodulation (tSNIP). Nerve localizationis necessary for tSNIP to avoid increased heating and for safer delivery. A computationalframework for neural stimulation of the wrist was developed to evaluate the effects oflateral electrode offset on nerve fiber activation for transverse tripolar, monopolar, andparallel tripolar electrode configurations. Sensitivity was defined as the reduction inactivated nerve fibers with increasing lateral offset within a clinically relevant stimulationwindow bounded by estimated pain and detection thresholds. The transverse tripoledemonstrated significantly greater sensitivity (p < 0.05) than monopolar and paralleltripolar configurations, indicating a rapid reduction in fiber activation with lateral offset.Human studies are needed to evaluate the clinical significance of LENS with a transversetripole."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.92","2.43 MB"]},{"key":"dc:title","label":"Title","values":["Localization Using Electrical Neural Stimulation (LENS) of Peripheral Nerves"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moffitt, Michael","Jenkins, Michael"],"dc:contributor.committeechair":["Durand, Dominique"],"dc:creator":["Witt, Margaret Adelaide"],"dc:date":["2026-08-14"],"dc:description":["In this study, we introduce Localization using Electrical Neural Stimulation (LENS) toidentify the median nerve and the ulnar nerve, enabling subsequent application oftransient Selective Neural Inhibition via Photobiomodulation (tSNIP). Nerve localizationis necessary for tSNIP to avoid increased heating and for safer delivery. A computationalframework for neural stimulation of the wrist was developed to evaluate the effects oflateral electrode offset on nerve fiber activation for transverse tripolar, monopolar, andparallel tripolar electrode configurations. Sensitivity was defined as the reduction inactivated nerve fibers with increasing lateral offset within a clinically relevant stimulationwindow bounded by estimated pain and detection thresholds. The transverse tripoledemonstrated significantly greater sensitivity (p < 0.05) than monopolar and paralleltripolar configurations, indicating a rapid reduction in fiber activation with lateral offset.Human studies are needed to evaluate the clinical significance of LENS with a transversetripole."],"dc:format":["application/pdf","p.92","2.43 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1780941601191802"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Transcutaneous Electrical Stimulation","Peripheral Nerves","transient Selective Neural Inhibition via Photobiomodulation","Transverse Tripole, Median Nerve, Ulnar Nerve, Neural Stimulation","McIntyre Richardson Grill (MRG) Model","Osteoarthritis","Electrode Offset","Paresthesia","Volume Conductor Model","Finite Element Model"],"dc:title":["Localization Using Electrical Neural Stimulation (LENS) of Peripheral Nerves"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:03:12Z"}