{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1783412783048211"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1783412783048211","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Patient Specific Margin Optimization in Offline Adaptive Radiotherapy","abstract":"This study provides a framework for a patient-specific statistical model for margin optimization in offline adaptive radiotherapy. Using the planning CT and first 5 CBCTs of patients undergoing bladder irradiation for muscle-invasive bladder cancer, bladder contours are converted into voxel-wise scalar fields using Signed Distance Functions to model anatomical variability. Mean and Standard Deviation maps were used to generate a library of three Planning Target Volume (PTV) sizes corresponding to target coverage pass rates of 60%, 80%, and 95%, defined as the percentage of treatment fractions achieving at least 98% coverage of daily bladder by the prescription isodose. These PTVs were evaluated on subsequent fractions and compared to conventional margin strategies. The SDF-based approach improved coverage while reducing the volume expansion ratio. Compared to benchmarkisotropic and anisotropic margin strategies, the SDF approach reduced the volume ratio, demonstrating the ability to enact patient-specific margin strategies to reduce normal tissue irradiation.","abstract_html":"This study provides a framework for a patient-specific statistical model for margin optimization in offline adaptive radiotherapy. Using the planning CT and first 5 CBCTs of patients undergoing bladder irradiation for muscle-invasive bladder cancer, bladder contours are converted into voxel-wise scalar fields using Signed Distance Functions to model anatomical variability. Mean and Standard Deviation maps were used to generate a library of three Planning Target Volume (PTV) sizes corresponding to target coverage pass rates of 60%, 80%, and 95%, defined as the percentage of treatment fractions achieving at least 98% coverage of daily bladder by the prescription isodose. These PTVs were evaluated on subsequent fractions and compared to conventional margin strategies. The SDF-based approach improved coverage while reducing the volume expansion ratio. Compared to benchmarkisotropic and anisotropic margin strategies, the SDF approach reduced the volume ratio, demonstrating the ability to enact patient-specific margin strategies to reduce normal tissue irradiation.","abstract_has_math":false,"creators":["Dyer, Samuel"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Zhang, Zhexuan"],"committee_members":[],"year":2026,"date_issued":"2026-08-14","date_published":"2026-08-14","updated_at":"2026-11-27T05:03:15Z","subjects":["Physics","Radiation","Adaptive radiotherapy","radiotherapy","bladder cancer","radiation therapy","Signed Distance Function","PTV optimization","medical physics"],"languages":["English"],"rights":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1783412783048211","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1783412783048211","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1783412783048211","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1783412783048211","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Zhang, Zhexuan"]},{"key":"dc:creator","label":"Author","values":["Dyer, Samuel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08-14"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Radiation","Adaptive radiotherapy","radiotherapy","bladder cancer","radiation therapy","Signed Distance Function","PTV optimization","medical physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1783412783048211"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study provides a framework for a patient-specific statistical model for margin optimization in offline adaptive radiotherapy. Using the planning CT and first 5 CBCTs of patients undergoing bladder irradiation for muscle-invasive bladder cancer, bladder contours are converted into voxel-wise scalar fields using Signed Distance Functions to model anatomical variability. Mean and Standard Deviation maps were used to generate a library of three Planning Target Volume (PTV) sizes corresponding to target coverage pass rates of 60%, 80%, and 95%, defined as the percentage of treatment fractions achieving at least 98% coverage of daily bladder by the prescription isodose. These PTVs were evaluated on subsequent fractions and compared to conventional margin strategies. The SDF-based approach improved coverage while reducing the volume expansion ratio. Compared to benchmarkisotropic and anisotropic margin strategies, the SDF approach reduced the volume ratio, demonstrating the ability to enact patient-specific margin strategies to reduce normal tissue irradiation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.39","3.92 MB"]},{"key":"dc:title","label":"Title","values":["Patient Specific Margin Optimization in Offline Adaptive Radiotherapy"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Zhang, Zhexuan"],"dc:creator":["Dyer, Samuel"],"dc:date":["2026-08-14"],"dc:description":["This study provides a framework for a patient-specific statistical model for margin optimization in offline adaptive radiotherapy. Using the planning CT and first 5 CBCTs of patients undergoing bladder irradiation for muscle-invasive bladder cancer, bladder contours are converted into voxel-wise scalar fields using Signed Distance Functions to model anatomical variability. Mean and Standard Deviation maps were used to generate a library of three Planning Target Volume (PTV) sizes corresponding to target coverage pass rates of 60%, 80%, and 95%, defined as the percentage of treatment fractions achieving at least 98% coverage of daily bladder by the prescription isodose. These PTVs were evaluated on subsequent fractions and compared to conventional margin strategies. The SDF-based approach improved coverage while reducing the volume expansion ratio. Compared to benchmarkisotropic and anisotropic margin strategies, the SDF approach reduced the volume ratio, demonstrating the ability to enact patient-specific margin strategies to reduce normal tissue irradiation."],"dc:format":["application/pdf","p.39","3.92 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1783412783048211"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["restricted--full text unavailable until 2027-02-14","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Radiation","Adaptive radiotherapy","radiotherapy","bladder cancer","radiation therapy","Signed Distance Function","PTV optimization","medical physics"],"dc:title":["Patient Specific Margin Optimization in Offline Adaptive Radiotherapy"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T05:03:15Z"}