{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1210341369"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1210341369","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Validation of the SenseWear HR Armband for measuring heart rate and energy expenditure","abstract":"The purpose of this study was to determine the validity of the SenseWear HR Armband in measuring heart rate and energy expenditure. The SenseWear HR Armband was compared to an electrocardiogram (ECG), the Actiheart Mini Mitter and the Polar Heart Rate Monitor. Energy expenditure estimations were compared to indirect calorimetry (Cosmed’s K4 b2) measurement and the Actiheart Mini Mitter’s estimations. Thirty healthy adults (18-59 years old) participated in the study. The protocol consisted of 5-minute stages, starting with two resting stages (sitting and standing), followed by four walking stages (1.5, 2.0, 2.5 and 3.0 mph) and ending with a standing recovery stage. The SenseWear HR Armband consistently recorded higher heart rate when (2-8 bpm) compared to the ECG, the Actiheart Mini Mitter (1-3 bpm) and the Polar Heart Rate Monitor (4-8 bpm). The SenseWear Armband overestimated energy expenditure by approximately 0.5-1.0 kcal/min during the exercise stages of the protocol when compared to the indirect calorimetry measurements, while the Actiheart Mini Mitter consistently underestimated (0.5kcal.min) energy expenditure. The SenseWear HR Armband was found to be a valid device for measuring heart rate; however, it consistently overestimated energy expenditure by about 10% during the exercise stages of the protocol.","abstract_html":"The purpose of this study was to determine the validity of the SenseWear HR Armband in measuring heart rate and energy expenditure. The SenseWear HR Armband was compared to an electrocardiogram (ECG), the Actiheart Mini Mitter and the Polar Heart Rate Monitor. Energy expenditure estimations were compared to indirect calorimetry (Cosmed’s K4 b2) measurement and the Actiheart Mini Mitter’s estimations. Thirty healthy adults (18-59 years old) participated in the study. The protocol consisted of 5-minute stages, starting with two resting stages (sitting and standing), followed by four walking stages (1.5, 2.0, 2.5 and 3.0 mph) and ending with a standing recovery stage. The SenseWear HR Armband consistently recorded higher heart rate when (2-8 bpm) compared to the ECG, the Actiheart Mini Mitter (1-3 bpm) and the Polar Heart Rate Monitor (4-8 bpm). The SenseWear Armband overestimated energy expenditure by approximately 0.5-1.0 kcal/min during the exercise stages of the protocol when compared to the indirect calorimetry measurements, while the Actiheart Mini Mitter consistently underestimated (0.5kcal.min) energy expenditure. The SenseWear HR Armband was found to be a valid device for measuring heart rate; however, it consistently overestimated energy expenditure by about 10% during the exercise stages of the protocol.","abstract_has_math":false,"creators":["Crawley, Manuella Barbosa"],"institution":"Cleveland State University","degree_name":"Master of Education","degree_level":"masters","degree_discipline":"College of Education and Human Services","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Sparks, Kenneth"],"committee_members":[],"year":2008,"date_issued":"2008-05-09","date_published":"2008-05-09","updated_at":"2026-11-27T04:15:00Z","subjects":["Health","Physical Education","Public Health","Sports Medicine","SenseWear HR Armband","heart rate","energy expenditure","validation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1210341369","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1210341369","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1210341369","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1210341369","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Sparks, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Crawley, Manuella Barbosa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-05-09"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Education and Human Services"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Education"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health","Physical Education","Public Health","Sports Medicine","SenseWear HR Armband","heart rate","energy expenditure","validation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1210341369"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to determine the validity of the SenseWear HR Armband in measuring heart rate and energy expenditure. The SenseWear HR Armband was compared to an electrocardiogram (ECG), the Actiheart Mini Mitter and the Polar Heart Rate Monitor. Energy expenditure estimations were compared to indirect calorimetry (Cosmed’s K4 b2) measurement and the Actiheart Mini Mitter’s estimations. Thirty healthy adults (18-59 years old) participated in the study. The protocol consisted of 5-minute stages, starting with two resting stages (sitting and standing), followed by four walking stages (1.5, 2.0, 2.5 and 3.0 mph) and ending with a standing recovery stage. The SenseWear HR Armband consistently recorded higher heart rate when (2-8 bpm) compared to the ECG, the Actiheart Mini Mitter (1-3 bpm) and the Polar Heart Rate Monitor (4-8 bpm). The SenseWear Armband overestimated energy expenditure by approximately 0.5-1.0 kcal/min during the exercise stages of the protocol when compared to the indirect calorimetry measurements, while the Actiheart Mini Mitter consistently underestimated (0.5kcal.min) energy expenditure. The SenseWear HR Armband was found to be a valid device for measuring heart rate; however, it consistently overestimated energy expenditure by about 10% during the exercise stages of the protocol."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.50","635.5 KB"]},{"key":"dc:title","label":"Title","values":["Validation of the SenseWear HR Armband for measuring heart rate and energy expenditure"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Sparks, Kenneth"],"dc:creator":["Crawley, Manuella Barbosa"],"dc:date":["2008-05-09"],"dc:description":["The purpose of this study was to determine the validity of the SenseWear HR Armband in measuring heart rate and energy expenditure. The SenseWear HR Armband was compared to an electrocardiogram (ECG), the Actiheart Mini Mitter and the Polar Heart Rate Monitor. Energy expenditure estimations were compared to indirect calorimetry (Cosmed’s K4 b2) measurement and the Actiheart Mini Mitter’s estimations. Thirty healthy adults (18-59 years old) participated in the study. The protocol consisted of 5-minute stages, starting with two resting stages (sitting and standing), followed by four walking stages (1.5, 2.0, 2.5 and 3.0 mph) and ending with a standing recovery stage. The SenseWear HR Armband consistently recorded higher heart rate when (2-8 bpm) compared to the ECG, the Actiheart Mini Mitter (1-3 bpm) and the Polar Heart Rate Monitor (4-8 bpm). The SenseWear Armband overestimated energy expenditure by approximately 0.5-1.0 kcal/min during the exercise stages of the protocol when compared to the indirect calorimetry measurements, while the Actiheart Mini Mitter consistently underestimated (0.5kcal.min) energy expenditure. The SenseWear HR Armband was found to be a valid device for measuring heart rate; however, it consistently overestimated energy expenditure by about 10% during the exercise stages of the protocol."],"dc:format":["application/pdf","p.50","635.5 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1210341369"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health","Physical Education","Public Health","Sports Medicine","SenseWear HR Armband","heart rate","energy expenditure","validation"],"dc:title":["Validation of the SenseWear HR Armband for measuring heart rate and energy expenditure"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["College of Education and Human Services"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Education"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:15:00Z"}