{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1236123539"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1236123539","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Experimental Test and Cost Analysis of Residential Solar Water Heaters","abstract":"Non renewable energy sources have been diminishing in the recent times.Renewable energy is abundant in nature, but the use of it is very low.Lowering the energy consumption and using renewable energy, thereby decreasing the use of fossil fuels and nuclear energy would have a positive impact on our environment. The use of solar energy as an alternate resource is discussed in this research. The solar water heater is tested for its recovery rates, under normal solar radiation in static testing. The effect of solar radiation in increasing the temperature of water is studied anddiscussed. The solar water heater is then brought in series with an electric hot water tank, used in residential purposes. The energy consumption by the hot water tank is first calculated, by testing the recovery rates of the hotwater tank. The hot water tank is then supplied with solar heated water and the recovery rates of the hot water tank are calculated. The energy consumption is calculated and the cost analysis is done in both the cases. The values of the energy consumed by the hot water tank with the use ofelectricity and solar heated water are compared. The DAQ system acts as an interface between the solar water heater and the hot water tank, which records and monitors the temperature data using thermocouples. The DC/AC adapter clamp and the multi meter, record the current usage by thehot water tank.","abstract_html":"Non renewable energy sources have been diminishing in the recent times.Renewable energy is abundant in nature, but the use of it is very low.Lowering the energy consumption and using renewable energy, thereby decreasing the use of fossil fuels and nuclear energy would have a positive impact on our environment. The use of solar energy as an alternate resource is discussed in this research. The solar water heater is tested for its recovery rates, under normal solar radiation in static testing. The effect of solar radiation in increasing the temperature of water is studied anddiscussed. The solar water heater is then brought in series with an electric hot water tank, used in residential purposes. The energy consumption by the hot water tank is first calculated, by testing the recovery rates of the hotwater tank. The hot water tank is then supplied with solar heated water and the recovery rates of the hot water tank are calculated. The energy consumption is calculated and the cost analysis is done in both the cases. The values of the energy consumed by the hot water tank with the use ofelectricity and solar heated water are compared. The DAQ system acts as an interface between the solar water heater and the hot water tank, which records and monitors the temperature data using thermocouples. The DC/AC adapter clamp and the multi meter, record the current usage by thehot water tank.","abstract_has_math":false,"creators":["Dharanikota, Sai Mahesh"],"institution":"Cleveland State University","degree_name":"Master of Science in Mechanical Engineering","degree_level":"masters","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Ebiana, Asuquo"],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T04:15:00Z","subjects":["Energy","Engineering","Mechanical Engineering","Solar Water Heater","Renewable Energy","Energy Consumption"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1236123539","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1236123539","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1236123539","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1236123539","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ebiana, Asuquo"]},{"key":"dc:creator","label":"Author","values":["Dharanikota, Sai Mahesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy","Engineering","Mechanical Engineering","Solar Water Heater","Renewable Energy","Energy Consumption"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1236123539"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Non renewable energy sources have been diminishing in the recent times.Renewable energy is abundant in nature, but the use of it is very low.Lowering the energy consumption and using renewable energy, thereby decreasing the use of fossil fuels and nuclear energy would have a positive impact on our environment. The use of solar energy as an alternate resource is discussed in this research. The solar water heater is tested for its recovery rates, under normal solar radiation in static testing. The effect of solar radiation in increasing the temperature of water is studied anddiscussed. The solar water heater is then brought in series with an electric hot water tank, used in residential purposes. The energy consumption by the hot water tank is first calculated, by testing the recovery rates of the hotwater tank. The hot water tank is then supplied with solar heated water and the recovery rates of the hot water tank are calculated. The energy consumption is calculated and the cost analysis is done in both the cases. The values of the energy consumed by the hot water tank with the use ofelectricity and solar heated water are compared. The DAQ system acts as an interface between the solar water heater and the hot water tank, which records and monitors the temperature data using thermocouples. The DC/AC adapter clamp and the multi meter, record the current usage by thehot water tank."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.97","839.7 KB"]},{"key":"dc:title","label":"Title","values":["Experimental Test and Cost Analysis of Residential Solar Water Heaters"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ebiana, Asuquo"],"dc:creator":["Dharanikota, Sai Mahesh"],"dc:date":["2008"],"dc:description":["Non renewable energy sources have been diminishing in the recent times.Renewable energy is abundant in nature, but the use of it is very low.Lowering the energy consumption and using renewable energy, thereby decreasing the use of fossil fuels and nuclear energy would have a positive impact on our environment. The use of solar energy as an alternate resource is discussed in this research. The solar water heater is tested for its recovery rates, under normal solar radiation in static testing. The effect of solar radiation in increasing the temperature of water is studied anddiscussed. The solar water heater is then brought in series with an electric hot water tank, used in residential purposes. The energy consumption by the hot water tank is first calculated, by testing the recovery rates of the hotwater tank. The hot water tank is then supplied with solar heated water and the recovery rates of the hot water tank are calculated. The energy consumption is calculated and the cost analysis is done in both the cases. The values of the energy consumed by the hot water tank with the use ofelectricity and solar heated water are compared. The DAQ system acts as an interface between the solar water heater and the hot water tank, which records and monitors the temperature data using thermocouples. The DC/AC adapter clamp and the multi meter, record the current usage by thehot water tank."],"dc:format":["application/pdf","p.97","839.7 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1236123539"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Energy","Engineering","Mechanical Engineering","Solar Water Heater","Renewable Energy","Energy Consumption"],"dc:title":["Experimental Test and Cost Analysis of Residential Solar Water Heaters"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:15:00Z"}