{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1284672860"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1284672860","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Risk-Based Approach for Examining Vertical Separation Distances in On-Site Wastewater Treatment Sytems","abstract":"Regulations regarding the use of on-site wastewater treatment systems in many states lack a sufficient scientific basis, which in many cases restricts the use of on-site systems, drives up cost, and restricts innovation of new treatment technologies. Of particular regulatory concern is the minimum vertical separation distance (VSD) located in the area between the trench bottom of the subsurface soil absorption system and any restricting or limiting layer. The minimum VSD needed for proper effluent treatment is based on many complex and interrelated factors regarding physical, chemical, and biological soil conditions at a particular site. Research has shown that depending on soil type and conditions, VSD between 1.5 feet and 4 feet is enough to adequately treat effluent yet many states use a “one size fits all” approach when setting regulations for on-site treatment systems. A stochastic mathematical model has been developed that provides an estimation of the probability that a contaminant concentration will reach a certain point below the trench bottom of the subsurface soil absorption system. This model has been incorporated into a simple, easy-to-use, Excel® based computer program that allows the user to evaluate the potential range of fecal coliform concentrations that may reach a specified groundwater or surface water location. This model has been developed to aid regulators, land use planners, and designers to quickly evaluate the associated risks of contamination from a specified on-site wastewater treatment system in a specified soil.","abstract_html":"Regulations regarding the use of on-site wastewater treatment systems in many states lack a sufficient scientific basis, which in many cases restricts the use of on-site systems, drives up cost, and restricts innovation of new treatment technologies. Of particular regulatory concern is the minimum vertical separation distance (VSD) located in the area between the trench bottom of the subsurface soil absorption system and any restricting or limiting layer. The minimum VSD needed for proper effluent treatment is based on many complex and interrelated factors regarding physical, chemical, and biological soil conditions at a particular site. Research has shown that depending on soil type and conditions, VSD between 1.5 feet and 4 feet is enough to adequately treat effluent yet many states use a “one size fits all” approach when setting regulations for on-site treatment systems. A stochastic mathematical model has been developed that provides an estimation of the probability that a contaminant concentration will reach a certain point below the trench bottom of the subsurface soil absorption system. This model has been incorporated into a simple, easy-to-use, Excel® based computer program that allows the user to evaluate the potential range of fecal coliform concentrations that may reach a specified groundwater or surface water location. This model has been developed to aid regulators, land use planners, and designers to quickly evaluate the associated risks of contamination from a specified on-site wastewater treatment system in a specified soil.","abstract_has_math":false,"creators":["Janicek, Anthony M."],"institution":"Cleveland State University","degree_name":"Master of Science in Civil Engineering","degree_level":"masters","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Tumeo, Mark"],"committee_members":[],"year":2010,"date_issued":"2010-09-17","date_published":"2010-09-17","updated_at":"2026-11-27T04:15:00Z","subjects":["Civil Engineering","Environmental Engineering","Environmental Science","on-site wastewater treatment","decentralized wastewater treatment","vertical separation distance"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1284672860","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1284672860","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1284672860","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1284672860","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Tumeo, Mark"]},{"key":"dc:creator","label":"Author","values":["Janicek, Anthony M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-09-17"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","Environmental Engineering","Environmental Science","on-site wastewater treatment","decentralized wastewater treatment","vertical separation distance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1284672860"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Regulations regarding the use of on-site wastewater treatment systems in many states lack a sufficient scientific basis, which in many cases restricts the use of on-site systems, drives up cost, and restricts innovation of new treatment technologies. Of particular regulatory concern is the minimum vertical separation distance (VSD) located in the area between the trench bottom of the subsurface soil absorption system and any restricting or limiting layer. The minimum VSD needed for proper effluent treatment is based on many complex and interrelated factors regarding physical, chemical, and biological soil conditions at a particular site. Research has shown that depending on soil type and conditions, VSD between 1.5 feet and 4 feet is enough to adequately treat effluent yet many states use a “one size fits all” approach when setting regulations for on-site treatment systems. A stochastic mathematical model has been developed that provides an estimation of the probability that a contaminant concentration will reach a certain point below the trench bottom of the subsurface soil absorption system. This model has been incorporated into a simple, easy-to-use, Excel® based computer program that allows the user to evaluate the potential range of fecal coliform concentrations that may reach a specified groundwater or surface water location. This model has been developed to aid regulators, land use planners, and designers to quickly evaluate the associated risks of contamination from a specified on-site wastewater treatment system in a specified soil."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.81","1.46 MB"]},{"key":"dc:title","label":"Title","values":["A Risk-Based Approach for Examining Vertical Separation Distances in On-Site Wastewater Treatment Sytems"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Tumeo, Mark"],"dc:creator":["Janicek, Anthony M."],"dc:date":["2010-09-17"],"dc:description":["Regulations regarding the use of on-site wastewater treatment systems in many states lack a sufficient scientific basis, which in many cases restricts the use of on-site systems, drives up cost, and restricts innovation of new treatment technologies. Of particular regulatory concern is the minimum vertical separation distance (VSD) located in the area between the trench bottom of the subsurface soil absorption system and any restricting or limiting layer. The minimum VSD needed for proper effluent treatment is based on many complex and interrelated factors regarding physical, chemical, and biological soil conditions at a particular site. Research has shown that depending on soil type and conditions, VSD between 1.5 feet and 4 feet is enough to adequately treat effluent yet many states use a “one size fits all” approach when setting regulations for on-site treatment systems. A stochastic mathematical model has been developed that provides an estimation of the probability that a contaminant concentration will reach a certain point below the trench bottom of the subsurface soil absorption system. This model has been incorporated into a simple, easy-to-use, Excel® based computer program that allows the user to evaluate the potential range of fecal coliform concentrations that may reach a specified groundwater or surface water location. This model has been developed to aid regulators, land use planners, and designers to quickly evaluate the associated risks of contamination from a specified on-site wastewater treatment system in a specified soil."],"dc:format":["application/pdf","p.81","1.46 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1284672860"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Civil Engineering","Environmental Engineering","Environmental Science","on-site wastewater treatment","decentralized wastewater treatment","vertical separation distance"],"dc:title":["A Risk-Based Approach for Examining Vertical Separation Distances in On-Site Wastewater Treatment Sytems"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Civil Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:15:00Z"}