{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:csu1308704453"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:csu1308704453","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"3D Imaging for Planning of Minimally Invasive Surgical Procedures","abstract":"<p>Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p>0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2>0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48±2.02 mGy indicating minimal radiation burden. </p><p>For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31% dose savings. Aortic luminal attenuation in VNC (32±2 HU) was similar to true non-contrast images (35±4 HU) indicating presence of unattenuated blood. To improve discrimination between calcium and iodine, a combined basis spectral and material analysis was developed. The algorithm differentiated calcium and iodinated pixels in phantom experiments and measured the mass fraction within 3%. Application in a patient resulted in VNC images with luminal attenuation of 57 HU indicating removal of contrast. However, high attenuating pixels with low density values appeared with decreased intensity in VNC images.</p>","abstract_html":"&lt;p&gt;Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p&gt;0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2&gt;0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48±2.02 mGy indicating minimal radiation burden. &lt;/p&gt;&lt;p&gt;For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31% dose savings. Aortic luminal attenuation in VNC (32±2 HU) was similar to true non-contrast images (35±4 HU) indicating presence of unattenuated blood. To improve discrimination between calcium and iodine, a combined basis spectral and material analysis was developed. The algorithm differentiated calcium and iodinated pixels in phantom experiments and measured the mass fraction within 3%. Application in a patient resulted in VNC images with luminal attenuation of 57 HU indicating removal of contrast. However, high attenuating pixels with low density values appeared with decreased intensity in VNC images.&lt;/p&gt;","abstract_has_math":false,"creators":["Numburi, Uma D."],"institution":"Cleveland State University","degree_name":"Doctor of Engineering","degree_level":"doctoral","degree_discipline":"Fenn College of Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Halliburton, Sandra"],"committee_members":[],"year":2011,"date_issued":"2011-06-22","date_published":"2011-06-22","updated_at":"2026-11-27T04:15:06Z","subjects":["Medical Imaging","Dual-energy CT (DECT)","C-arm CT"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1308704453","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=csu1308704453","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acsu1308704453","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acsu1308704453","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Halliburton, Sandra"]},{"key":"dc:creator","label":"Author","values":["Numburi, Uma D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-06-22"]},{"key":"dc:publisher","label":"Institution","values":["Cleveland State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Fenn College of Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cleveland State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medical Imaging","Dual-energy CT (DECT)","C-arm CT"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1308704453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p>0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2>0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48±2.02 mGy indicating minimal radiation burden. </p><p>For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31% dose savings. Aortic luminal attenuation in VNC (32±2 HU) was similar to true non-contrast images (35±4 HU) indicating presence of unattenuated blood. To improve discrimination between calcium and iodine, a combined basis spectral and material analysis was developed. The algorithm differentiated calcium and iodinated pixels in phantom experiments and measured the mass fraction within 3%. Application in a patient resulted in VNC images with luminal attenuation of 57 HU indicating removal of contrast. However, high attenuating pixels with low density values appeared with decreased intensity in VNC images.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.270","5.82 MB"]},{"key":"dc:title","label":"Title","values":["3D Imaging for Planning of Minimally Invasive Surgical Procedures"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Halliburton, Sandra"],"dc:creator":["Numburi, Uma D."],"dc:date":["2011-06-22"],"dc:description":["<p>Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p>0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2>0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48±2.02 mGy indicating minimal radiation burden. </p><p>For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31% dose savings. Aortic luminal attenuation in VNC (32±2 HU) was similar to true non-contrast images (35±4 HU) indicating presence of unattenuated blood. To improve discrimination between calcium and iodine, a combined basis spectral and material analysis was developed. The algorithm differentiated calcium and iodinated pixels in phantom experiments and measured the mass fraction within 3%. Application in a patient resulted in VNC images with luminal attenuation of 57 HU indicating removal of contrast. However, high attenuating pixels with low density values appeared with decreased intensity in VNC images.</p>"],"dc:format":["application/pdf","p.270","5.82 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=csu1308704453"],"dc:language":["English"],"dc:publisher":["Cleveland State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Medical Imaging","Dual-energy CT (DECT)","C-arm CT"],"dc:title":["3D Imaging for Planning of Minimally Invasive Surgical Procedures"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Fenn College of Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Engineering"],"thesis:institution_name":["Cleveland State University"]},"updated_at":"2026-11-27T04:15:06Z"}